Lab.gruppen PLM 20K44 Operation Manual page 69

Plm+ series powered loudspeaker management system
Hide thumbs Also See for PLM 20K44:
Table of Contents

Advertisement

9.3.2. Input and Router Defaults
Autoselect:
On
Input sensitivity:
+26 dBu
Dante:
Disabled
AES3:
Terminated
Iso-Float:
Enabled
Router 1:
Priority 1 = Dante Receiver (Ch.1)
Priority 2 = Dante Receiver (Ch.5)
Priority 3 = AES1 (Ch.1)
Priority 4 = Analog 1
Router 2:
Priority 1 = Dante Receiver (Ch.2)
Priority 2 = Dante Receiver (Ch.6)
Priority 3 = AES1 (Ch.2)
Priority 4 = Analog 2
Router 3:
Priority 1 = Dante Receiver (Ch.3)
Priority 2 = Dante Receiver (Ch.7)
Priority 3 = AES1 (Ch.3)
Priority 4 = Analog 3
Router 4:
Priority 1 = Dante Receiver (Ch.4)
Priority 2 = Dante Receiver (Ch.8)
Priority 3 = AES1 (Ch.4)
Priority 4 = Analog 4
9.3.3. Amplifier and Device Defaults
Attenuation:
Polarity:
Mutes:
Load Model:
Breaker Emulation Limiter:
IP Configuration:
Dual Redundancy:
Dante Slave Only:
0 dB
Positive (In phase)
Unmuted
No Load Model
PLM 20K44 - 32A
PLM 12K44 - 25A
Auto Zero Conf. (Auto IP)
Disabled
Enabled
PLM+ SERIES Operation Manual rev 1.0.0
9. Appendix
69

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plm 12k44

Table of Contents