the fan speed is kept at low speed.
The total time is 7 hours, after 7 hours the unit stops
11.11.3 Heating:
The set temperature decrease 1℃ per hour. Two hours later, the set temperature will maintain as a
constant and the air circulation is kept at low speed (Anti-cold function takes precedence over all).
The total time is 7 hours, after 7 hours the unit stops
11.11.4 Auto:
After an hour running under economic mode, the set temp will rise 1℃,if it is under cooling mode; the set
temp will decrease 1℃,if it is under heating mode; the set temp will be changeless, if it is under fan-only
mode; the condition will be the same after the air conditioner running under economic mode after 2 hours,
and during the next time the set temp do not change. The total time is 7 hours, after 7 hours the unit stops.

11.12 Auto restart function

In case of a sudden power failure, this function automatically sets the unit to previous settings before the
power failure when power returns

11.13 Turbo mode

In cooling mode, when pressing the turbo button on the remote controller, the unit will enter turbo mode with
ultra-high speed and reach the set temperature more quickly. After running 20 minutes in turbo mode, the
indoor fan will automatically recover the preset speed.

11.14 PLASMA (optional)

Starts with indoor fan.
Note: Plasma and Anion can be use together

11.15 Anion(optional)

Starts with indoor fan.
Note: Plasma and Anion can be use together