Pressure Table; Mse-21Crn2; Mse-21Hrn2 - Vivax ACP-24CH70AEB Service Manual

Hide thumbs Also See for ACP-24CH70AEB:
Table of Contents

Advertisement

9. Pressure table

Note:
The pressure data is from 3 way valve, the pressure data are pressure above atmosphere.
D: Dry bulb temp.
W: Wet bulb temp.

9.1 MSE-21CRN2

cooling mode
indoor
pressure
conditions
pressure
21℃ D
(kg/cm2)
15℃ W
pressure
24℃ D
(kg/cm2)
17℃ W
pressure
27℃ D
(kg/cm2)
19℃ W
pressure
32℃ D
(kg/cm2)
23℃ W

9.2 MSE-21HRN2

cooling mode
indoor
pressure
conditions
pressure
21℃ D
(kg/cm2)
15℃ W
pressure
24℃ D
(kg/cm2)
17℃ W
pressure
27℃ D
(kg/cm2)
19℃ W
pressure
32℃ D
(kg/cm2)
23℃ W
heating mode
indoor conditions
15℃
18℃
20℃
22℃
22
outdoor temperature(Dry bulb temp)
25℃
30℃
4.4
4.5
4.5
4.6
4.8
4.9
5.2
5.4
outdoor temperature(Dry bulb temp)
25℃
30℃
4.4
4.5
4.5
4.6
4.8
4.9
5.2
5.4
outdoor conditions
12℃ D
pressure
11℃ W
pressure
23.0
(kg/cm2)
pressure
24.0
(kg/cm2)
pressure
24.5
(kg/cm2)
pressure
24.8
(kg/cm2)
Service manual
35℃
40℃
4.6
4.7
4.7
4.8
5.1
5.1
5.6
5.7
35℃
40℃
4.6
4.7
4.7
4.8
5.1
5.1
5.6
5.7
7℃ D
0℃ D
6℃ W
-1℃ W
21.9
19.3
22.7
20.6
23.1
21.0
23.9
22.4
45℃
50℃
4.8
4.9
5.0
5.1
5.2
5.4
5.8
6.0
45℃
50℃
4.8
4.9
5.0
5.1
5.2
5.4
5.8
6.0
(-4℃ D)
(-7℃ D)
(-6℃ W)
(-9℃ W)
18.5
16.9
19.2
17.4
20.0
18.3
21.2
19.5
(-15℃ D)
(-x℃ W)
/
/
/
/