SAFETY REGULATIONS
FOR YOUR SAFETY
DO
NOT
STORE
OR
USE
GASOLINE
OR
OTHER
FLAMMABLE
VAPOURS
AND LIQUIDS IN THE VICINITY
OF THIS OR ANY OTHER APPLIANCE.
DO NOT ATTEMPT
TO START
THE
BURNER
WHEN
EXCESS
OIL
HAS
ACCUMULATED.
WHEN
THE
FURNACE
IS
FULL
OF
VAPOUR
OR
WHEN
THE
COMBUSTION
CHAMBER IS VERY HOT.
1.1
DANGER, WARNING AND CAUTION
The words DANGER, WARNING
and CAUTION are used to
identify
the levels of seriousness
of certain hazards.
It is
important that you understand their meaning. You will notice
these words in the manual as follows:
_1_
DANGER
CSA B139
ANSI/NFPA 31
ANSI/NFPA 90B
ANSI/NFPA 211
ANSI/NFPA 70
IMPORTANT:
All local
and
national
code
requirements
governing
the installation
of oil burning equipment,
wiring
and flue connections
must be followed.
Some of the codes
that may be applicable are:
Installation Code for Oil Burning
Equipment
Installation of Oil Burning Equipment
Warm Air Heating and Air Conditioning
Systems
Chimneys, Fireplaces, Vents and Solid
Fuel Burning Appliances
National Electrical Code
CSA C22.2 No.3 Canadian Electrical Code
Only the latest issues of the above codes should be used,
and are available from either:
The National Fire Protection Agency
1 Batterymarch
Park
Quincy, MA 02269
or
The Canadian Standards Association
178 Rexdale Blvd.
Rexdale, Ontario M9W 1R3
Hazards or unsafe practices which CAN result in death
or serious bodily and/or
material damage.
Hazards or unsafe practices which CAN result in minor
bodily and/or
material damage.
ENVIRONMENTAL
HAZARD
Failure
to
follow
this
caution
may
result
in
environmental
pollution.
Remove and recycle all components
or materials
(i.e.
oil, electrical
and
electronic
components,
insulation,
etc.) before unit final disposal.
1.2
SAFETY INSTALLATION
REQUIREMENTS
For use with grade 2 fuel oil maximum.
Do NOT use
gasoline, crankcase oil or any oil containing gasoline.
Never burn garbage or paper in the heating system and
never leave rags or paper around the unit.
I
These
instructions
are intended
for the sole use of l
qualified
personnel
trained
in installing
this type of I
=
furnace.
Installation
of this furnace
by an unqualified I
person can lead to hazardous
conditions,
resulting
in I
bodily harm and/or equipment
damage.
I
2.0
INSTALLATION
2.1
GENERAL
This central heating unit is a true multi-position
unit, in that it
can operate
in four different
configurations,
i.e., upflow,
counter flow (downftow),
and horizontal
(both left-to-right
and right-to-left airflow).
Very few modifications
are required
during installation,
to
change the furnace from one configuration
to another. The
furnace
is shipped
in the upflow
configuration;
however,
instructions on how to change to the other configurations
are
included in this manual.
The furnace is shipped complete with burner and controls. It
requires a 115VAC line voltage connection
to the control
panel, thermostat hook-up as shown on the wiring diagram,
one or more oil line connections,
suitable
ductwork
and
connection to a properly sized vent.
The air handling
capacity of this furnace
is designed
for
cooling as well. Please refer to Table 6 for the expected
airflow at various external static pressures.