2.3.2.6 Recovery Test

To view the recovery test data follow the procedure below:
1.
Press the program key
are still in the low level programming mode from a previous procedure you will not need to
enter the password.
2.
Press the zero (0) product key. The display will change to show "SELECT".
3.
Next press the six (6) product key to enter the recovery test program. The display will
change to indicate "RECOVERY".
4.
To display the recovery test data press the six (6) key again. The display will change to
display the recovery test data (F###L###).
5.
The display indicates the time it took the fryer to heat up from 250°F to 300°F at the factory
and the last time the recovery test was performed. The F### portion of the display
indicates the time in seconds that the fryer took to heat up at the factory. The L###
indicates the heat up time in seconds the fryer took the last time the test was performed.
6.
After viewing the recovery test data press the program key
mode.
7.
To exit the programming mode press the program key

2.3.2.7 Computer Control Mode

The computer can be switched from control mode to timer mode. In timer mode the computer
does not control the fryer. To change the computer mode from control to timer follow the
procedure below:
1.
Press the program key
are still in the low level programming mode from a previous procedure you will not need to
enter the password.
2.
Press the zero (0) product key. The display will change to show "SELECT".
3.
Next press the seven (7) product key to enter the computer control program. The display will
change to indicate "CONTROL" or "TIMER".
4.
To toggle between the two modes of control press the zero (0) product key. Each of the
settings (CONTROL or TIMER) will be displayed as the zero (0) key is pressed.
and enter the password (if a password is programmed). If you
and enter the password (if a password is programmed). If you
2-11
to return to the program
again.