1.3.2.3 Quick Disconnect Gas Connection

Gas fryers equipped with casters must be installed with connectors
that comply with the Standard for Connectors for Movable Gas
Appliances, ANSI Z21.69-1987, and Addenda Z21.69A-1989. This
connection should include a quick disconnect device that complies
with the Standard for Quick Disconnect Devices for Use With Gas
Fuel, ANSI Z21.41-1989. When installing a quick disconnect you
must also install a means for limiting the movement of the fryer.
This device will prevent the gas line or the quick disconnect from
being strained. The restraining device should be attached to the
cooker on the back panel as shown in the illustration. The quick
disconnect, hose, and restraining device can be obtained from your
dealer.

1.3.2.4 Fuel Supply Line Leak and Pressure Testing

The fuel supply system must be tested before the fryer is used. If the fuel line is going to be tested at a
pressure greater than (>)1/2 PSIG (3.45 kPa), make sure that the fryer is disconnected from the fuel line. If
the fuel line is to be tested at a pressure equal to or less than (<) 1/2 PSIG (3.45 kPa), the fryer can be
connected but the unit's gas valve must be shut. Test all gas line connections for leaks with a solution of
soap and water when pressure is applied.

1.3.3 Electrical Connection

The electrical service used by the fryer must comply with local codes. If there are no local codes that apply,
refer to the National Electrical Code (NEC) to install the service. In Canada refer to CSA Standard C22.1
and local codes. Wiring diagrams are provided inside the fryer control box. The power requirements for the
fryer are shown below.
Input Voltage
Current per fryer
UFM Filter System
The fryer is equipped with an oil proof, three prong (grounding) plug for your
protection against electrical shock hazard in the event of equipment
malfunction. DO NOT cut or remove the grounding (third) prong from this
plug. This plug must be plugged into a properly grounded three prong
receptacle.
1-5
North America
120VAC,60Hz
0.5 Amps
7.0 Amps
International
220 (or 240) VAC, 50Hz
0.5 Amps
4.0 Amps