    H&V Products PRELIMINARY Tranquility 22 Digital (TZ) Series ® 97B0072N01 Residential Horizontal & Vertical Packaged Geothermal Heat Pumps Installation, Operation & Maintenance Instructions Created: 26 Oct., 2011B Table of Contents Model Nomenclature Electrical - Thermostat Wiring Storage ECM Blower Control Pre-Installation Blower Data Vertical Installation...
  • Page 2 This page was intentionally left blank.
  • Page 3: Model Nomenclature

    ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Model Nomenclature: General Overview 4 5 6 0 2 4...
  • Page 4: Storage

    ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B General Information Inspection CAUTION!
  • Page 5: Vertical Installation

    ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Vertical Installation Figure 1: Vertical Unit Mounting Vertical Unit Location...
  • Page 6: Condensate Piping For Vertical Units

    ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Vertical Installation Sound Attenuation for Vertical Units - Sound attenuation Condensate Piping for Vertical Units - Install condensate...
  • Page 7: Horizontal Installation

    ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Horizontal Installation Horizontal Unit Location Mounting Horizontal Units...
  • Page 8 ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Horizontal Installation Figure 7a: Typical Closed Loop Horizontal Unit Installation (with Internal Flow Controller) 3/8"...
  • Page 9: Field Conversion Of Air Discharge

    ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Field Conversion of Air Discharge Overview - Horizontal units can be fi...
  • Page 10: Horizontal Condensate Connection

    ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Horizontal Installation Condensate Piping Condensate Piping –...
  • Page 11: Water Connection Installation

    ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Water Connection Installation Tranquility ®...
  • Page 12: Heat Pump Applications

    ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Heat Pump Applications Figure 12a: Typical Ground-Loop Application (with Internal Flow Controller Shown) CAUTION!
  • Page 13: Ground Loop Heat Pump Applications

    ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Ground-Loop Heat Pump Applications With industry leading ‘plug and play’...
  • Page 14: Flushing The Earth Loop

    ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Flushing the Earth Loop Once piping is completed between the unit and the ground WARNING!
  • Page 15 ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Flushing the Earth Loop NOTICE: Actual fl...
  • Page 16 ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Flushing the Earth Loop Move valves to position D.
  • Page 17 ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Ground Loop Heat Pump Applications Antifreeze Selection - General WARNING!
  • Page 18 ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Ground Loop Heat Pump Applications Table 2: Antifreeze Percentages by Volume Minimum Temperature for Low Temperature Protection...
  • Page 19 ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Ground Loop Heat Pump Applications antifreeze has been added to the system.
  • Page 20: Low Temperature Cutout Selection

    ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Ground Loop Heat Pump Applications range from approximately 15-50 psi [103-345 kPa].
  • Page 21: Internal Flow Controller Pump Curves

    ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Internal Flow Controller Pump Curves Chart 2: Internal Variable Speed Flow Controller Maximum Performance Magna Geo 25-140 Pump Curve...
  • Page 22: Pump Replacement Procedure

    ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Pump Replacement Procedure may not be feasible, the loop can also be re-fl...
  • Page 23: Ground Water Heat Pump Applications

    ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Ground-Water Heat Pump Applications Figure 17: Typical Open Loop/Well Application To Thermostat...
  • Page 24 ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Ground-Water Heat Pump Applications recharge well, storm sewer, drain fi...
  • Page 25: Water Quality Standards

    ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Water Quality Standards Table 3: Water Quality Requirements Water Quality...
  • Page 26: Hot Water Generator

    ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Hot Water Generator The HWG (Hot Water Generator) or desuperheater option Electric water heaters are recommended.
  • Page 27 ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Hot Water Generator If the control has detected a HWG fault, the DXM2 status Installation...
  • Page 28: Hot Water Generator

    ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Hot Water Generator 5.
  • Page 29: Electrical - Line Voltage

    ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Electrical - Line Voltage WARNING! CAUTION!
  • Page 30 ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Electrical - Line Voltage Figure 21: TZ Single Phase Line Voltage WARNING!
  • Page 31: Electrical - Low Voltage Wiring

    ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Electrical - Low Voltage Wiring Figure 23: LT1 Limit Setting Thermostat Connections...
  • Page 32: Electrical - Thermostat Wiring

    CAUTION! CAUTION! Refrigerant pressure activated water regulating valves should never be used with ClimateMaster equipment. Figure 25a: Communicating Thermostat Connection to DXM2 Control...
  • Page 33: Ecm Blower Control

    ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B ECM Blower Control The ECM fan is controlled directly by the DXM2 control board rpm at blower start up.
  • Page 34: Blower Data

    ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Tranquility 22 (TZ) Series ECM Blower Performance Data ®...
  • Page 35: Dxm2 Controls

    ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B DXM2 Controls DXM2 Control - For detailed control information, see DXM2 relay will NOT cycle during test mode.
  • Page 36 ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B DXM2 Controls 2.4 - Accessory2 relay personality: DIP 2.4 provides 3.4 –...
  • Page 37 ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B DXM2 Controls DXM2 Control Start-up Operation Figure 26: Test Mode Button...
  • Page 38 ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B DXM2 Controls Table 8: Nominal resistance at various temperatures DXM2 Thermostat Details...
  • Page 39: Unit Commissioning And Operating Conditions

    ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Unit Commissioning And Operating Conditions Operating Limits Environment –...
  • Page 40: Unit Start-Up And Operating Conditions

    ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Unit Start-Up and Operating Conditions operate in the proper sequence.
  • Page 41: Unit Start-Up Procedure

    ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Unit Start-Up Procedure to provide a water seal.
  • Page 42: Coax Pressure Drop Table

    ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Unit Operating Conditions Table 10: TZ Coax Water Pressure Drop Table 11: Water Temperature Change Through Heat...
  • Page 43 ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Unit Operating Conditions Table 13: TZ Series Typical Unit Operating Pressures and Temperatures Full Load Cooling - without HWG active...
  • Page 44: Unit Operating Conditions

    ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Unit Operating Conditions Table 13: TZ Series Typical Unit Operating Pressures and Temperatures: Continued Full Load Cooling - without HWG active...
  • Page 45: Performance Data

    ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Table 14a: Performance Data —...
  • Page 46 ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Table 14b: Performance Data —...
  • Page 47 ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Table 14c: Performance Data —...
  • Page 48 ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Table 14d: Performance Data —...
  • Page 49 ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Table 14e: Performance Data —...
  • Page 50: Performance Data

    ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Table 14f: Performance Data —...
  • Page 51: Performance Data Selection Notes

    ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Performance Data Selection Notes For operation in the shaded area when water is used in lieu of an anti-freeze solution, the LWT (Leaving Water...
  • Page 52: Pressure Drop

    ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Pressure Drop Table 15a: Polyethylene Pressure Drop per 100ft of Pipe Antifreeze (30°F [-1°C] EWT): 20% Methanol by volume solution - freeze protected to 15°F [-9.4°F]...
  • Page 53 ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Pressure Drop Table 15b: Polyethylene Pressure Drop per 100ft of Pipe Antifreeze (30°F [-1°C] EWT): 25% Propylene Glycol by volume solution - freeze protected to 15°F [-9.4°F]...
  • Page 54 ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Pressure Drop Table 15c: Polyethylene Pressure Drop per 100ft of Pipe Antifreeze (30°F [-1°C] EWT): 25% Ethanol by volume solution - freeze protected to 15°F [-9.4°F]...
  • Page 55: Pressure Drop

    ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Pressure Drop Table 15d: Polyethylene Pressure Drop per 100ft of Pipe No Antifreeze (50°F [10°C] EWT): Water...
  • Page 56: Preventive Maintenance

    ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Preventive Maintenance Water Coil Maintenance Condensate Drain...
  • Page 57: Troubleshooting

    ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Troubleshooting General is sending a “W”...
  • Page 58: Dxm2 Process Flow Chart

    ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B DXM2 Process Flow Chart WARNING! WARNING! HAZARDOUS VOLTAGE! DISCONNECT...
  • Page 59: Functional & Performance Troubleshooting

    ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Functional Troubleshooting Fault Htg Clg Possible Cause...
  • Page 60 ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Functional Troubleshooting (cont.) Fault Htg C lg Possible Cause...
  • Page 61: Performance Troubleshooting

    ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Performance Troubleshooting Symptom Htg Clg Possible Cause...
  • Page 62: Troubleshooting Form

    ® R es id ential D i g i tal H &V - Tr an q u ilit y 22 Digital (T Z ) S e rie s - 60Hz HF C-4 10 A C r e a t e d : 2 6 O c t . , 2 0 1 1 B Troubleshooting Form Refrigerant Circuit Diagram Date: ________________________...
  • Page 63 ® R esid entia l D i gi tal H &V - Tran qu ilit y 22 Digit al (T Z) S e rie s - 60Hz HFC -4 1 0A C r e a t e d : 2 6 O c t . , 2 0 1 1 B c l i m a t e m a s t e r.
  • Page 64: Revision History

    97B0072N01 ClimateMaster works continually to improve its products. As a result, the design and specifi cations of each product at the time for order may be changed without notice and may not be as described herein. Please contact ClimateMaster’s Customer Service Department at 1-405-745-6000 for specifi...