FAN MAINTENANCE

1. Follow steps 1-11 on previous page to access fan.
2. Disconnect fan wires and ground wire.
3. Remove 2 wing nuts to remove fan.
4. .Slide fan down and lift up and out to remove.
5. Replace or service fan
6. Reverse steps 5-1 to reinstall fan.
Regency GFI300L Gas Fireplace Inbuilt
PRESSURE SWITCH REPLACEMENT
Before you start ensure all power is turned off.
1. Disconnect wire leads and tubing on the switch.
NOTE: It is important to label wires and hose connections to ensure
the new switch is hooked up in the same manner.
2. Remove the two screws on the mounting bracket.
3. Slide switch out to the left side.
4. Remove switch and replace.
5. Reverse steps to complete installation.