MAINTENANCE
VALVE TRAY REPLACEMENT
1. Unplug or disconnect the power source to the unit.
2. Shut off the gas supply and remove the gas connection from the valve.
3. Remove the faceplate, door frame, safety glass or screen.
4. Remove the glass door. (See door removal section in this manual).
5. Remove the logs. (See log section in this manual).
6. Remove the panels. (See panel section in this manual).
7. Remove the log tray, by removing 2 screws in locations shown below.
8. Lift log tray up and out to remove.
9. Remove burner - loosen screw on left side, remove screw from right side
- slide to the right and lift up and out to remove.
Loosen
26
10. Remove 2 screws in location shown below to remove front bracket.
11. Remove 8 screws to remove valve tray - lift up and out to remove.
12. Replace valve tray and reverse steps 11-1.
Remove