Flueing; Test For Flue Spillage - Regency Fireplace Products GFI300LNG-R Owners & Installation Manual

Table of Contents

Advertisement

DRAFT DIVERTER
CONNECTION
1) Attach the fl ue to the fl ue collar on the detach-
able draft diverter. The fl ue collar of the appli-
ance will fi t inside a standard fl ue and may be
fastened directly to the fl ue by sheet metal
screw. Diagram 1.
Diagram 1
2) Before pushing the appliance into position inside
the fi replace, align the draft diverter with the
guides on the insert top and push forward. While
pushing the unit back into place keep pulling the
draft diverter forward until the screw hole in the
spill tube aligns with the screw hole in the top
of the fi rebox. The screw is secured through the
inside top of the fi rebox into the bottom of the
spill tube. (If screw holes do not line up then
draft diverter is not positioned correctly.)
Diagram 2.
Diagram 2
NOTE: Final gas connection should be after unit
is in place to avoid damage to line when
pushing the unit into position.
Regency GFI300L Gas Fireplace Inbuilt
GAS CONNECTION
GAS CONNECTION WARNING:
Only persons licensed to work with
gas piping may make the necessary
gas connections to this appliance.
1) If the appliance is to be installed into an existing
chimney system, thoroughly clean the masonry
or factory built fi replace.
2) The gas connection is 12" BSP.
3) Locate the center point where the fl ue will pass
through the chimney above the appliance. Move
the appliance into the exact location where it is
to be installed. Ensure that the Insert is level.
4) The installer must provide a valve with a plugged
tapping, accessible for test gauge connection,
immediately upstream of the gas supply con-
nection to the appliance.
CAUTION: If the glass is removed or opened for
servicing, it must be replaced and closed prior
to operating the appliance. The glass must be
fi xed in the door when operating.

FLUEING

THE APPLIANCE MUST NOT BE CONNECTED
TO A CHIMNEY FLUE SERVING A SEPARATE
SOLID FUEL BURNING APPLIANCE.
This appliance is designed to attach to a 100
mm diameter twin skin or listed gas fuel type
fl ue liner running the full length of the chimney.
A minimum fl ue height of 0.6 m. is required for
masonry applications. The Regency Inbuilt Fireplace
incorporates its own internal draft diverter, so no
additional external draft diverter is required.
Periodically check that the fl ue is unrestricted and
an adequate draft is present when the unit is in
operation. (See page 7 for spillage test.)
Before installing fl ue system ensure that the damper
plate is open and secure to prevent the damper plate
from falling down and crushing the liner.
Install to AS5601-2004,(Australia) NZS 5261 (New
Zealand).
Combustion and Ventilation Air
WARNING: This appliance needs fresh
air for safe operation and must be
installed with provisions for adequate
combustion and ventilation air avail-
able to the room in which it is to be
operating.
Air for combustion is drawn in through the front of
the unit, therefore, the front of the unit must be kept
clear of any obstructions.
INSTALLATION
TEST FOR FLUE
SPILLAGE
A " spillage" test must be made before the
installed unit is left with the customer. Follow
the procedure below:
1) Start all exhaust fans in the home and then
close all external doors and windows in the
house.
2) Light the unit and set controls to maximum.
Turn fan off.
3) After fi ve minutes, test that there is a "pull"
on the fl ue by placing a smoke match, or
similar device which gives off smoke, in both
sides of the unit. See diagram 1.
normal draft
downdraft
or block flue
Diagram 1
The smoke should be drawn into the unit. If the
smoke is still not drawn into the spill tube, turn the
unit off and check for the cause of the lack of draft.
If necessary, rectify.
For wind turbulent sites, a wind cap may remedy
the problem. These caps are not included with the
standard fl ue kit and will need to be purchased
separately.
Flue spillage
test location area
13