Gas Connection - Regency Fireplace Products GFI300LNG-R Owners & Installation Manual

Table of Contents

Advertisement

INSTALLATION

GAS CONNECTION

GAS CONNECTION WARNING:
Only persons licensed to work with gas piping may make
the necessary gas connections to this appliance.
1) If the appliance is to be installed into an existing chimney system, thoroughly
clean the masonry or factory built fi replace.
2) The gas connection is 12" BSP.
3) Locate the center point where the fl ue will pass through the chimney above
the appliance. Move the appliance into the exact location where it is to be
installed. Ensure that the Insert is level.
4) The installer must provide a valve with a plugged tapping, accessible for
test gauge connection, immediately upstream of the gas supply connection
to the appliance.
CAUTION: If the glass is removed or opened for servicing, it must be
replaced and closed prior to operating the appliance. The glass must be
fi xed in the door when operating.
SPECIFICATIONS
NG
Injector
#40
Size
Input
Max. 30
Rating
mj
Min.
20mj
Manifold
0.87 kPa 2.3 kPa
Pressure
Aeration
5 mm
Setting
12
LP
ULPG
#53
#55
Max. 27
Max. 24
mj
mj
Min. 22
Min. 19
mj
mj
2.3 kPa
13 mm
full
open
Regency GFI300L Gas Fireplace Inbuilt

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gfi300llp-rGfi300lulpg-r

Table of Contents