7.10 Passwords

Scenario 1: Requiring a password to start the operator terminal
If the dip switch SW6 = ON, the user needs to enter a password to start the
operator terminal. For this purpose, the designer can use the object Action
Button in CP400Soft to create a button which displays the password table on
the operator terminal display. A user with the right to access the table can register
passwords and user levels in the table.
In the illustration below, the
password table. When the button is selected the password table is displayed on
the screen for a user with the right to access the table. Touch the password to
highlight an area for entering a value.
How to configure an Action Button is described in the CP400Soft User's
Manual.
After registering passwords and user levels, set the dip switch SW6 = ON
(i.e. password required). Restart the operator terminal and after the self-test the
user will be prompted to enter a password in order to run the operator terminal.
The operator terminal will determine the user level from the entered password.
For instance, if the level of the password entered by the user is 2, then the oper-
ator terminal will set the user level to 2. User level 1 has the highest privilege and
User level 9 has the lowest.
Note:
Only users of User Level 1 has the right of access to the password table.
ABB, 1SBC159105M0202
button is an action button used to display the
Operation
25