ABB CP430 Installation And Operation Manual

ABB CP430 Installation And Operation Manual

Human machine interface

Advertisement

Quick Links

CP430
Installation and Operation Manual
English
ABB, 1SBC159103M0201 2007-05

Advertisement

Table of Contents
loading

Summary of Contents for ABB CP430

  • Page 1 CP430 Installation and Operation Manual English ABB, 1SBC159103M0201 2007-05...
  • Page 2 Document number: ABB, 1SBC159103M0201 Please read the entire installation manual prior to installing and using this equipment. Only qualified personnel may install, operate or repair this equipment. ABB is not responsible for modified, altered or renovated equipment. Because the equipment has a wide range of applications, users must acquire the appropriate knowledge to use the equipment properly in their specific applications.
  • Page 3 Foreword ABB, 1SBC159103M0201...
  • Page 4: Table Of Contents

    System Menu ................18 Key Pad..................19 Bench and Function Tests ............20 Setting Parameters..............20 Downloading an Application ............. 21 Uploading an Application ............22 Uploading/Downloading a Recipe ..........23 Copying an Application ............. 24 7.10 Passwords................... 25 ABB, 1SBC159103M0201...
  • Page 5 Contents ABB, 1SBC159103M0201...
  • Page 6: Safety Precautions

    – The supplier neither guarantees that the operator terminal is suitable for your particular application, nor assumes responsibility for your product design, in- stallation or operation. ABB, 1SBC159103M0201...
  • Page 7 Dismantling and Scrapping – The operator terminal or parts thereof shall be recycled according to local regulations. – The following components contain substances that might be hazardous to health and the environment: lithium battery, electrolytic capacitor and display. ABB, 1SBC159103M0201...
  • Page 8: Installation

    – Operator terminal CP430 – 4 installation fasteners – Power connector (connected to the 24 V DC power outlet) – Printer cable (only for CP430 B-ETH, CP430 C and CP430 C-ETH) – This installation and operation manual (1SBC159103M0201) ABB, 1SBC159103M0201...
  • Page 9: Product Specifications

    Product Specifications Product Specifications Parameter CP430 C-ETH CP430 C CP430 B-ETH CP430 B Front panel, 195.0 x 145.0 x 4.2 mm W x H x D Mounting depth 59.1 mm Cut-out dimensions 185.8 x 135.8 mm Front panel IP 65/NEMA 4...
  • Page 10: Description Of Parts

    Product Specifications Parameter CP430 C-ETH CP430 C CP430 B-ETH CP430 B Storage temperature -10 ° to +60 °C Ambient humidity 20 - 90% RH non-condensed Vibration endurance 0.5 mm displacement, 10-55 Hz, 2 hours per X-, Y- and Z-axis directions...
  • Page 11 Product Specifications Back Battery cover Printer/keyboard connection DC power outlet DIP switches (1-10) Contrast adjustment COM1: RS232/RS485 COM2: RS232/RS422/RS485 Network connection ABB, 1SBC159103M0201...
  • Page 12: External And Cut-Out Dimensions

    Product Specifications External and Cut-out Dimensions Unit: mm CUTOUT DIMENSION Mounting Procedure 1. Cut out the control front panel to match the dimensions (mm) below. ABB, 1SBC159103M0201...
  • Page 13: Grounding

    3. The operator terminal is to be installed within the angle of 0 to 135 shown below. Grounding To make sure that the operator terminal works properly and to prevent it from radiating radio frequency noise, it must be connected to the earth ground. ABB, 1SBC159103M0201...
  • Page 14: Power Supply And Wiring

    Product Specifications Power Supply and Wiring CP430 must use the power supply with 24 V DC and the power consumption is 20W. Warning: To avoid an electrical shock, be sure to switch off the power before connecting the communication/download cable to the operator terminal.
  • Page 15: Dip Switches

    The default user level is set to 9 if the operator terminal requires no password to start its operation. Reserved SW10 COM2 Port For RS485, this switch has to be set ON. For RS422, this switch has to be set OFF. ABB, 1SBC159103M0201...
  • Page 16: Communication Ports

    RS422 TX- (RS485-) RS232 TXD RS232 RXD RS422 RX+ RS232 RTS RS422 RX- Signal ground RS232 CTS RS485- RS232 RTS Signal ground RS232 CTS Optional; +5V@100mA output Optional; +5V@100mA output RS422 RTS+ RS422 RTS- RS422 CTS+ RS422 CTS- ABB, 1SBC159103M0201...
  • Page 17: Lcd Contrast Adjustment

    See also section 7.2 System Menu. The contrast can also be adjusted using the potentiometer on the back of the operator terminal. Use a small screwdriver to turn the potentiometer (clockwise = contrast down; counter-clockwise = contrast up). ABB, 1SBC159103M0201...
  • Page 18: Operation

    After downloading again, all items should pass the self-test. Note: When using the operator terminal for the first time, remember to reset the real time clock (RTC). ABB, 1SBC159103M0201...
  • Page 19: System Menu

    + and - to set the value of the field. F3 - Copy Copies application data to another CP430. F4 - Set Adjusts touch panel LCD contrast and clears data RAM. See also section 6 LCD Contrast Adjustment.
  • Page 20: Key Pad

    Operation Key Pad The six keys on the CP430 include one menu key and five functional keys (F1- F5), described below. Press the menu key to slide out the innovative slide-out menu. The functional keys can also be defined in CP400Soft and used as “Quick- buttons”, for example, to set an ON/OFF value, to change a screen etc.
  • Page 21: Bench And Function Tests

    Bench and Function Tests Set dip switches SW3 and SW4 = OFF to be able to run the bench and function tests for the CP430. Turn on the operator terminal to display the following screen: The bench test performs an overall hardware test, and the function test lets the user select which item to be tested.
  • Page 22: Downloading An Application

    Operation Downloading an Application Connect the RS232 port on the PC to the COM1 port on the CP430 using a TK401 cable, or to the COM2 port using a TK402 cable. The connection can also be made according to the illustration below, where the...
  • Page 23: Uploading An Application

    Then the operator terminal will prompt for a password: enter the password set in CP400Soft from Application/Workstation Setup. Once the correct password is entered, the operator terminal starts to upload the application to the PC. For information about setting a password, please see section 7.10 Passwords. ABB, 1SBC159103M0201...
  • Page 24 *.V6F file. Thus a source file can serve the purposes of maintenance and modification. Note: When uploading for the first time, make sure to first run the application once, or else the upload function will not work. ABB, 1SBC159103M0201...
  • Page 25: Uploading/Downloading A Recipe

    Also remember to upload the format of recipes from the operator terminal be- fore starting to edit a new set of recipe data in the PC. For further information about creating/editing recipes, please see the corre- sponding chapter in the CP400Soft User’s Manual. ABB, 1SBC159103M0201...
  • Page 26: Copying An Application

    Operation Copying an Application To copy an application from one CP430 to another CP430, select F3 - Copy from the system menu. Set the dip switch SW7 = ON and connect the two op- erator terminals with a download cable. After the self-test, the system menu will be displayed on the screen.
  • Page 27 After registering passwords and user levels, set the dip switch SW6 = ON (i.e. password required). Restart the operator terminal and after the self-test the user will be prompted to enter a password in order to run the operator terminal. ABB, 1SBC159103M0201...
  • Page 28 Therefore, this button can be applied to raise or drop one’s privileges while the operator terminal is in operation. How to configure an Action Button is described in the CP400Soft User’s Manual. ABB, 1SBC159103M0201...
  • Page 29 When selecting F3 - Copy in the system menu or File/Upload Application in CP400Soft, the operator terminal will prompt for a password. The user will need to enter the correct password to copy an application from one CP430 to another. Note that setting this password is different from the passwords set in Scenarios 1-3.
  • Page 30 ABB FRANCE ABB STOTZ-KONTAKT GmbH Division Automation Products Po Box 10 16 80 Export Department 69006 Heidelberg 10 rue Ampère Germany 69685 Chassieu Tel. : +49 (0) 6221/701-1190 France Fax. : +49 (0) 6221/701-1333 Tel. : +33 (0) 4 72 22 17 22 Fax.

This manual is also suitable for:

Cp430 c-ethCp430 cCp430 bCp430 b-eth