ABB CP600 Operating Instructions Manual

ABB CP600 Operating Instructions Manual

Control panels with microbrowser
Hide thumbs Also See for CP600:

Advertisement

Operating Instructions
WinCE Edition, Version 6.0
CP600
Control Panels with
MicroBrowser
CP620-WEB
CP630-WEB
CP635-WEB
CP650-WEB
CP660-WEB
CP675-WEB


Advertisement

Table of Contents
loading

Summary of Contents for ABB CP600

  • Page 1 Operating Instructions CP600 Control Panels with MicroBrowser WinCE Edition, Version 6.0 CP620-WEB CP630-WEB CP635-WEB CP650-WEB CP660-WEB CP675-WEB ...
  • Page 2: Table Of Contents

    License ..........................3 Abbreviations ........................4 Overview ..........................5 First Steps .......................... 6 CoDeSys Visualizations ....................9 XML Configuration File ....................11 Keyboard Shortcuts......................20 Configuration of an AC500 visualization ............... 21 CoDeSys MicroBrowser FAQ ..................22 Operating Instructions CP600/Issue: 09.2011...
  • Page 3: Before You Start

    Precondition for an operation instruction or a description.  Operation instruction with one step. Operation instruction with several steps.  Result of an operation. Helpful information with background information or an emphasized notice. NOTE Application tips or other useful information and suggestions. Operating Instructions CP600/Issue: 09.2011...
  • Page 4: License

    OS/2 is a registered trademark of IBM Inc. Pentium is a registered trademark by Intel Inc. SpiderControl is a registrated trademark by IniNet Solutions GmbH, Switzerland. SpiderLink is the internal API name from IniNet Solutions GmbH, Switzerland. Operating Instructions CP600/Issue: 09.2011...
  • Page 5: Abbreviations

    MMI. Container A container is a local variable, which has a scope within the actual applet/view. Containers are used to exchange values between different painters in a view or between different views of the same applet. Operating Instructions CP600/Issue: 09.2011...
  • Page 6: Overview

    Ethernet gives an easy and professional graphical interface to the AC500 PLC. Depending on the type of AC500 up to 12 CP600-WEB Control Panels can access the AC500 webserver at a time. The built-in 2-port-Ethernet-switch of some CP600-WEB Control Panels makes an additional switch un- necessary while programming and testing or connecting more than one Control Panel to the AC500.
  • Page 7: First Steps

    Change the IP address of the CP6xx-WEB Control Panel by using the soft input panel or connected USB-Keyboard. IMPORTANT: To make this change permanent, exit the Network Connections and double click on the icon Registry Save on the desktop. Operating Instructions CP600/Issue: 09.2011...
  • Page 8 To access the CoDeSys web server of AC500 type webvisu.htm in the field Path or full URL. If you select the checkbox Always use these settings this configuration dialog will not appear any- more, unless you change to Kiosk-Mode or NoKiosk-Mode like described above. Operating Instructions CP600/Issue: 09.2011...
  • Page 9  If a newer version of the MicroBrowser is available just replace the file My Device\Flash\MicroBrowser\MicroBrowser_CE.exe with the new one copied on a USB- Stick. Be careful to select the right file for your Control Panel type. Operating Instructions CP600/Issue: 09.2011...
  • Page 10: Codesys Visualizations

    Text variables (dynamic change)  Text flags  Font height  Font name  Font flags These configuration possibilities are NOT supported:  Color variables (dynamic change): Frame flags  Variables: Tooltip-display  Text for Tooltip Operating Instructions CP600/Issue: 09.2011...
  • Page 11 These special input possibilities are NOT supported:  LANGUAGEDIALOG  DEFINERECEIPT  READRECEIPT  WRITERECEIPT  SAVEWATCH  LOADWATCH Operating Instructions CP600/Issue: 09.2011...
  • Page 12: Xml Configuration File

    <loading msg>1;0;Loading...;0,0,0,0;0,0,0;0,0,0;</loading msg> <show selection>0</show selection> <config page></config page> <config file></config file> <httpd debug level>0</httpd debug level> <boot delay sec>0</boot delay sec> <set width>0</set width> <set height>0</set height> <inactivity to sec>0</inactivity to sec> <inactivity pts ms>0</inactivity pts ms> Operating Instructions CP600/Issue: 09.2011...
  • Page 13 These properties contain username and password for the portal. Please contact iniNet for details. <prompt_url> Registration Code The license key is already available in the CP6xx-WEB Control Panel. There is no need to enter a regis- tration code. Operating Instructions CP600/Issue: 09.2011...
  • Page 14 Debug level for the webserver. 0 will turn logging off, 2 is the maximum. This option will help you to see the incoming requests from any browser on the webserver. The output file is “eweb.log”. Default is 0. Operating Instructions CP600/Issue: 09.2011...
  • Page 15 Label: Text in button. x,y,width,height: Allows to configure the position and the size of the button. bgndRed,bgndGreen, bgndBlue; fgndRed,fgndGreen,fgndBlue : Allows to define the fore- ground and background color in decimal RGB code. Default: 1;0;!;1,1,23,23;255,128,64;0,0,0; Example: 1;0;Warning!;1,1,80,30;255,128,64;0,0,0; Operating Instructions CP600/Issue: 09.2011...
  • Page 16 Browser expects that the configuration project is placed relative to the program path, in the subfolder MB_Config and the file MB_Config.html. See also chapter “<config_file> Configuration File”. <config_file> Configuration File Define the configuration file used to store data from configuration project. Operating Instructions CP600/Issue: 09.2011...
  • Page 17 SAIA alarming and offline trend, where time zone is not sup- ported. The TMZ can be set dynamically, by writing 0 or 1 in the predefined container variable “MB_tmz_en”. Default is 0 (disabled). Example: 1 (enabled) Operating Instructions CP600/Issue: 09.2011...
  • Page 18 Browser will use the SpiderLink API to load files. And caching files depending on the parameter <teq_cache>. Default is 1 (enabled). Example: 0 (disabled) <mfc_http_cache> MFC HTTP Cache This option works if parameter <mfc_http_en> is enabled. It allows to set options of the Windows cache. Default is 1 (re-synchronize) Operating Instructions CP600/Issue: 09.2011...
  • Page 19 Example: <storage_path>\FlashDrv\Log\</storage_path> <built_in_dialog> Built-In Dialog Set this option to 1 to enable, or 0 to disable the built-in dialog, to open trend and alarm log files. Default is disabled, the standard Windows Open File dialog is used: Operating Instructions CP600/Issue: 09.2011...
  • Page 20 CoDeSys HMI into a SpiderControl HMI. In that case both, the .xml and .teq files, are being generated and stored on the local storage system. <export_path> Export Path This is the path to which the files are exported, when the export setting is enabled <export_en>1</export_en>. Operating Instructions CP600/Issue: 09.2011...
  • Page 21: Keyboard Shortcuts

    To open the dialog and modify the URL: Alt-O (or Shift-O if enabled). By clicking the OK button, the Mi- croBrowser will generate the configuration file (uBrowser.xml) again, with the current settings. Toggle Full Screen To toggle full screen on MicroBrowser XP: Alt-F11 The hot key Alt-F11 is also disabled on Kiosk-Mode 3. Operating Instructions CP600/Issue: 09.2011...
  • Page 22: Configuration Of An Ac500 Visualization

    Set the number of connections according to the following rule: Number of connections = (number of clients x 2) + 1. Each CP600-WEB Control Panel is one client. Check “Use 8.3 format” and “Web visualization” and uncheck “Inhibit download of visualization files to PLC”.
  • Page 23: Codesys Microbrowser Faq

    After a change of target system in the Control Builder Plus the settings for the webserver are reset. Open the settings CoDeSys/Resources/target settings/visualization. Check Visualization and uncheck Inhibit download of visualization files. Watchlists (Recipies) can not be saved or loaded The MicroBrowser does not support watchlists. Operating Instructions CP600/Issue: 09.2011...
  • Page 24  ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82 Postfach 101680 69123 Heidelberg, Germany 69006 Heidelberg, Germany Telephone (06221) 701-0 Telefax (06221) 701-240 E-Mail automation-helpline.desto@de.abb.com Internet http://www.abb.de/stotz-kontakt...

This manual is also suitable for:

Cp630-webCp620-webCp635-webCp650-webCp660-webCp675-web

Table of Contents