Ethernet And Console Ports - Aerohive AP330 User Manual

Hide thumbs Also See for AP330:
Table of Contents

Advertisement

Chapter 1 Aerohive AP330 and AP350

Ethernet and Console Ports

There are three ports on the AP330 and AP350: two RJ-45 10/100/1000Base-T/TX Ethernet ports and an RJ-45
console port.
The pin assignments in the Ethernet ports follow the TIA/EIA-568-B standard (see
standard types of Ethernet cable—cat3, cat5, cat5e, or cat6. Because the ports have autosensing
capabilities, the wiring termination in the Ethernet cable can be either straight-through or cross-over.
Figure 2
PoE wire usage and pin assignments
Pin numbers
8
1
ETH0
(View of the ETH0
PoE Port)
MDI = Medium dependent interface for straight-through connections
MDI-X = Medium dependent interface for cross-over (X) connections
The Eth0 PoE port is auto-sensing and can automatically adjust to transmit and receive data over straight-through or
cross-over Ethernet connections. Likewise, it can automatically adjust to 802.3af Alternative A and B power delivery
methods. Furthermore, when the Alternative A method is used, the port automatically allows for polarity reversals
depending on their role as either MDI or MDI-X. In 802.3at, the 1/2 and 3/6 wire pairs connect to DC source 1 and 4/5
and 7/8 pairs to DC source 2 in PSE. Although the exact polarity depends on the PSE design, the Eth0 PoE port can
support all possible options.
T568A-terminated Ethernet
cable with an RJ-45 connector
T568B-terminated Ethernet
cable with an RJ-45 connector
10
802.3af Alternative A
(data and power on the
same wires)
Pin
Data Signal
MDI
1
Transmit +
DC+
2
Transmit -
DC+
3
Receive +
DC–
4
(unused)
– – –
5
(unused)
– – –
6
Receive -
DC–
7
(unused)
– – –
8
(unused)
– – –
Pin
Pin
802.3af Alternative B
(data and power on
separate wires)
MDI-X
MDI or MDI-X
DC–
– – –
DC–
– – –
DC+
– – –
– – –
DC+
– – –
DC+
DC+
– – –
– – –
DC–
– – –
DC–
T568A Wire Color
1
White/Green
2
Green
3
White/Orange
4
Blue
5
White/Blue
6
Orange
7
White/Brown
8
Brown
T568B Wire Color
1
White/Orange
2
Orange
3
White/Green
4
Blue
5
White/Blue
6
Green
7
White/Brown
8
Brown
Figure
2). The ports accept
802.3at wring options
1
2
3
DC1+
DC1–
DC1+
DC1+
DC1–
DC1+
DC1–
DC1+
DC1–
DC2+
DC2+
DC2–
DC2+
DC2+
DC2–
DC1–
DC1+
DC1–
DC2–
DC2–
DC2+
DC2–
DC2–
DC2+
T568A and T568B are two
standard wiring termination
schemes. Note that the only
difference between them is that
the white/green + solid green pair
of wires and the white/orange +
solid orange pair are reversed.
For straight-through Ethernet
cables—using either the T568A or
T568B standard—the eight wires
terminate at the same pins on
each end.
For cross-over Ethernet cables,
the wires terminate at one end
according to the T568A standard
and at the other according to
T568B.
4
DC1–
DC1–
DC1+
DC2–
DC2–
DC1+
DC2+
DC2+
Aerohive

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ap350

Table of Contents