Configuring Edge Switch Parameters - HP StorageWorks Edge Switch 2/12 Installation Manual

Hide thumbs Also See for StorageWorks Edge Switch 2/12:
Table of Contents

Advertisement

Configuring Edge Switch parameters

Perform this procedure to configure the following Edge Switch and fabric operating parameters:
Buffer-to-Buffer Credit (BB_Credit), Error Detect Time Out Value (E_D_TOV), Resource Allocation
Time Out Value (R_A_TOV), preferred domain ID and switch priority.
To configure Edge Switch parameters:
1.
Set the Edge Switch offline (see
2.
Select Configure > Switch > Parameters.
The Parameters view is displayed
NOTE:
clearing the Insistent Domain ID has no effect.
Figure 19
Parameters view
3.
Set the Edge Switch parameters:
c. Select (enable) or clear (disable) the Rerouting Delay check box.
If rerouting delay is enabled, traffic is delayed through a fabric by the specified E_D_TOV
time. This delay ensures Fibre Channel frames are delivered to their destination in order, even
if a change to the fabric topology creates a new (shorter) transmission path.
d. Select (enable) or clear (disable) the Domain RSCN check box.
Domain register for state change notifications (domain RSCNs) are sent between end devices
in a fabric to provide additional connection information to HBAs and storage devices. For
example, this information might be that a logical path has been broken because of a
physical event, such as a fiber optic cable being disconnected from a port. Consult with your
HBA and storage device vendor to determine if enabling Domain RSCNs will cause
problems with your HBA or storage products.
42
Using the HAFM Basic interface
"Setting the Edge Switch offline and
(Figure
The Insistent Domain ID is not supported on the Edge Switch 2/12. Selecting or
19).
online" on page 37).