Refit the glass frame as detailed in section on page 6, then light the appliance as
detailed on page 4.
To ensure that the release of fibres from these R.C.F (Refractory Ceramic
Fibre) articles is kept to a minimum, during installation and servicing we
recommend that you use a HEPA filtered vacuum to remove any dust
accumulated in and around the appliance before and after working on the
appliance. When replacing these articles we recommend that the replaced
items are not broken up, but are sealed within heavy duty polythene bags,
clearly labelled as "RCF waste". RCF waste is classed as a "stable", non
reactive hazardous waste and may be disposed of at a landfill licensed to
accept such waste Protective clothing is not required when handling these
articles, but we recommend you follow the normal hygiene rules of not
smoking, eating or drinking in the work area, and always wash your hands
before eating or drinking.
USER REPLACEABLE PARTS
The only user replaceable parts on this fire are the fuelbed / coal form, which may
be replaced as described in the above section. Replacement of any other parts
must be carried out by a competent person such as a CORGI registered gas
installer.
The part numbers of the user replaceable parts are as follows, these are available
from BFM Europe Ltd. who may be contacted at the address shown on the below.
Fuelbed
Due to our policy of continual improvement and development the exact
accuracy of descriptions and illustrations cannot be guaranteeD.
Telephone - General Enquiries :
Telephone - Service :
70-47800
Part No. B-103840
Issue 3
BFM Europe Ltd.
Trentham Lakes
Stoke-on-Trent
Staffordshire
ST4 4TJ
www.bfm-europe.com
(01782) 339000
(0844) 7700169