Changing the light bulb

Lamp specifications: 220-240V, max. 10W
To turn off the device, set the temperature control to setting 0 - OFF.
Disconnect the plug or turn off the fuse!
-
Press central on the lamp cover and take the cover sidewise off.
-
Replace defect illuminant.
-
Reattach the lamp cover.
-
Reconnect the device and turn on.

Repairs

WARNING: Servicing of electric devices must be conducted by qualified experts only. Incorrect or
improper repairs constitute a risk for the user and will void the warranty!
What if . . . Troubleshooting
The design of the device ensures a trouble-free operation as well as a long life cycle. Nevertheless, if
any defect occurs during operation, please check if it is caused by improper operation.
The following problems can be solved by you by checking for the possible cause.
PROBLEM
POSSIBLE CAUSE
The device is
Is the plug securely connected to the mains?
not working
Has the safety mechanism of the wall socket
properly or at
been triggered?
all
Is the temperature control properly set?
Is the place unqualified?
Do food items or shelves and/or drawers
prevent the door from closing properly?
Is the ventilation of the device hedged?
Appliances
Is the temperature control set properly?
cools too
much
The food is
Is the temperature control set properly?
too warm
Door was open for an extended period.
A large quantity of warm food was placed in
the appliances within the last 24 hours.
The appliance is near a heat source.
Loud noise
Does the device not stand vertical or horizon-
during opera-
tal?
tion
Water on the
Is the temperature control set properly?
bottom
Is the condensate flume clogged?
Light does not
Is the plug not connected to the mains?
work
Has the safety mechanism of the wall socket
been triggered?
Is the light bulb defect?
Note. On days of high humidity, condensation might occur on the outer surface of the device. This is
no malfunction; you may simply wipe the water off.
If a problem still persists after following the steps above, please contact your distributor or a techni-
cian.
Are you interested in other Bomann products? Please visit our website:
Distribution: C. Bomann GmbH • Heinrich-Horten-Str. 17 • D-47906 Kempen
SOLUTION
Connect the plug properly to the socket, turn
on the fuse, and contact a technician if nec-
essary.
Check the settings.
Check the ambient temperature.
Arrange the food or shelves and/or drawers
properly.
Clear the ventilation slits, install the device
freely.
Check the temperature setting.
Check the temperature setting.
Open the door only as long as necessary.
Turn the control panel to a colder setting tem-
porally.
Please refer to the 'Installation' section.
Adjust the feet accordingly.
Liquid flow sounds in the cooling circuit are
normal.
Check the temperature setting.
Clean the discharge opening with a pipe
cleaner or knitting needle.
Connect the plug properly to the socket, turn
on the fuse, and contact a technician if nec-
essary.
Disconnect the plug and replace the light bulb
(see 'Changing the light bulb').