NSTALLATION

Location

Sufficient ventilation around the device is necessary in order for the heat to dissipate properly and to
guarantee efficient cooling operation at low power consumption. For this purpose, leave sufficient
space around the device.
-
Minimum clearance of 7,5 cm between rear side and wall,
-
at least 10 cm on both sides and 10 cm on top of the device.
-
Leave proper space in front of the device in order to open the door at an angle of 160° .
IMPORTANT:
-
Do not expose the device to direct sunlight.
-
Do not place near heaters, next to a stove or any other heat sources.
-
Only install at a location with an ambient temperature suitable for the climate class of the device.
For information on the climate class, please refer to chapter "Specifications" or to the rating label
located in the interior or on the rear side of the device.
-
Do not use the device outdoors.
-
Avoid installation at locations with high humidity (e.g. outdoors, bathroom), as metal parts would be
susceptible to corrosion under such circumstances.
-
Do not place the device near volatile or combustible materials (e.g. gas, fuel, alcohol, paint, etc.)
and in rooms which may have poor air circulation (e.g. garages).
-
Only place on a steady and safe surface.
-
If the device is not horizontally leveled, adjust the feet accordingly.

Electrical connection

The kind of current (AC) and the voltage must be conform with the data of the rating label, located
inside or outside on the back of the unit. In case of heavy voltage fluctuations, it is recommended to
use an automatic alternating current regulator.
The plug, together with the grounding conductor, must fit into the wall socket. The mains plug must be
freely accessible.
Mains cable
-
Do not extend or roll up the cable during operation.
-
Also, the cable must not be near the compressor on the rear side, since latter one gets hot during
operation. In case of any contact, the isolation would be damaged resulting in electric leakage.
-
The use of extension cables is not recommended.
-
Do not connect the device to the mains with wet hands.
-
Install the device for the wall socket to be freely accessible.
R
T
D
EVERSE
HE
OOR
If required, the door openings can be moved from the right (supplied condition) to the left side.
WARNING: When replacing the door stops, the device must be disconnected from the power
supply. Always unplug the device first.
1. Use a flat bladed screw driver to remove the screw covers at the device cover. Unscrew the below
screws and remove the device cover.
2. Put the blind cap of the device cover at the opposite side.