Removing A Negative Temperature Coefficient (Ntc) Sensor - KitchenAid KICU508SBL Technical Education

Touch-activated electronic
Hide thumbs Also See for KICU508SBL:
Table of Contents

Advertisement

REMOVING A NEGATIVE TEMPERATURE
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug cooktop or disconnect power.
2.
Remove the cooktop glass from the cooktop
(see page 4-2 for the procedure).
Left NTC Sensors
3.
Depending on the negative temperature
coefficient (NTC) sensor you are servicing,
remove the screws from the left or right
induction element assembly mounting plate
(see page 4-4 for the procedure).
4.
Unhook the two cover tabs and remove
the cover from the induction element NTC
sensor you are replacing (see page 4-5 for
the procedure).
COEFFICIENT (NTC) SENSOR
Right NTC Sensors
5.
Unplug the NTC sensor connector from
the electronic board as shown in the chart
below. NOTE: If necessary, refer to the
Wiring Diagrams in Section 7 for the con-
nector locations.
ELEMENT LOCATION
LF
LR
C
RF
RR
LEB = Left Electronic Board
MEB = Middle Electronic Board (5 element models)
REB = Right Electronic Board
6.
Unhook the tabs on the NTC sensor, pull
the sensor off the element, and remove it.
4-6
NTC CONNECTOR
CNT3 (LEB)
CNT1 (LEB)
CNT1 (MEB)
CNT3 (REB)
CNT1 (REB)
Tabs
NTC Sensor
Tabs

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kicu568sbl

Table of Contents