Negative Temperature Coefficient (Ntc) Sensor - KitchenAid KICU508SBL Technical Education

Touch-activated electronic
Hide thumbs Also See for KICU508SBL:
Table of Contents

Advertisement

Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
NEGATIVE TEMPERATURE
COEFFICIENT (NTC) SENSOR
Refer to page 4-6 for the procedure for ac-
cessing the negative temperature coefficient
(NTC) sensor.
NOTE: Each of the inductors uses a negative
temperature coefficient (NTC) sensor for moni-
toring the operating temperature. The sensors
are interchangeable. Use conductive grease
when replacing a sensor to aid in thermal con-
duction.
1.
Unplug cooktop or disconnect power.
2.
Disconnect the NTC wires from the elec-
tronic board.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch one of the ohmmeter test leads to
the pins of the NTC connector. The meter
should indicate as shown in the charts.
WARNING
Electrical Shock Hazard
Temp (°F)
50
51.8
53.6
55.4
57.2
59
60.8
62.6
64.4
66.2
68
69.8
71.6
73.4
75.2
77
Temp (°C)
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
5-2
R (k Ω)
Temp (°F)
R (k Ω)
98.264
78.8
47.788
93.229
80.6
45.794
88.632
82.4
43.873
84.404
84.2
42.019
80.489
86
40.228
76.845
87.8
38.496
73.435
89.6
36.819
70.233
91.4
35.193
67.213
93.2
33.616
64.357
95
32.085
61.647
96.8
30.597
59.070
98.6
29.150
56.613
100.4
27.741
54.264
102.2
26.369
52.016
104
26.065
49.860
R (k Ω)
Temp (°C)
R (k Ω)
98.264
26
47.788
93.229
27
45.794
88.632
28
43.873
84.404
29
42.019
80.489
30
40.228
76.845
31
38.496
73.435
32
36.819
70.233
33
35.193
67.213
34
33.616
64.357
35
32.085
61.647
36
30.597
59.070
37
29.150
56.613
38
27.741
54.264
39
26.369
52.016
40
26.065
49.860