INSTALLATION INSTRUCTIONS
HB0104
CC32I SERIES
!
INTENDED FOR DOMESTIC COOKING ONLY
!
READ AND SAVE THESE INSTRUCTIONS
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 13 AND 14.
Venmar Ventilation ULC, 550 Lemire Blvd., Drummondville QC J2C 7W9 1-800-567-3855
REGISTER YOUR PRODUCT ONLINE AT: www.bnv.ca
For additional information - visit www.venmar.ca
21238 rev. 01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CONNAISSEUR CC32I SERIES and is the answer not in the manual?

Questions and answers

Bill Nowostawsky
April 21, 2025

How do i change LED lights in a venmar connaisseur Hood range

2 comments:
Bill Nowostawsky
April 21, 2025

@Bill Nowostawsky

Mr. Anderson
May 11, 2025

The documents do not provide specific instructions for changing the LED lights in the Venmar Connaisseur CC32I Series hood range. However, the LED module is listed as a replaceable part (part no. 62612). To change the LED lights, you would typically need to:

1. Turn off power at the main electrical panel.
2. Access the LED module inside the hood.
3. Disconnect and remove the old LED module.
4. Install the new LED module (part no. 62612).
5. Restore power and test the lights.

Refer to the installation guide for exact steps.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Venmar CONNAISSEUR CC32I SERIES

  • Page 1 READ AND SAVE THESE INSTRUCTIONS INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER. HOMEOWNER: USE AND CARE INFORMATION ON PAGES 13 AND 14. Venmar Ventilation ULC, 550 Lemire Blvd., Drummondville QC J2C 7W9 1-800-567-3855 REGISTER YOUR PRODUCT ONLINE AT: www.bnv.ca For additional information - visit www.venmar.ca...
  • Page 2: To Reduce The Risk Of Fire, Electric Shock Or Injury To Persons, Observe The Following

    Open a window close to or in the kitchen. 10. To reduce the risk of fire and electrical shock, the Venmar Connaisseur CC32I Series models should only be installed with their own built-in blowers.
  • Page 3 CC32I SERIES RANGE HOOD SYSTEMS - ODEL ODEL ODEL 3¼” 10” (8” STANDARD ROOF CAP ROUND WALL CAP WALL CAP 8” R OUND ADJUSTABLE ELBOW OPTIONAL LENUM SUPPLIED 09025 WITH DUCT KIT PPER DECORATIVE FLUE 8” R OUND METAL FLEXIBLE ODEL DUCT SUPPLIED...
  • Page 4: Prepare The Installation

    1. PREPARE THE INSTALLATION WARNING When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves. NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer. Make sure that the following items are included: - Hood - Accessories...
  • Page 5: Remove Grease Filters

    2. SELECT INSTALLATION TYPE (CONT'D) Refer to illustrations below to locate duct opening according to discharge type chosen (grey parts to be installed later). ERTICAL DISCHARGE ORIZONTAL DISCHARGE 30” ⁄ ” OR NON DUCTED WIDTH HOOD 36” ⁄ ” WIDTH HOOD INSTALLATION ⁄...
  • Page 6 5. BLOWER REMOVAL (HORIZONTAL DISCHARGE ONLY) The CC32I Series range hoods are factory shipped with the blower mounted for a vertical discharge configuration. For a horizontal discharge configuration, disassemble the blower from the inner top of the hood (see illustrations below). It will be assembled to the inner back of the hood once the hood is mounted on the wall.
  • Page 7: Wiring Installation

    7. WIRING INSTALLATION WARNING Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions are not completely understood, or if there is any doubt as to whether the appliance is properly grounded. Do not use an extension cord.
  • Page 8: Install Hood Mounting Bracket

    8. INSTALL HOOD MOUNTING BRACKET WARNING ALL STUDS When cutting or drilling into wall, do not damage electrical wiring and other hidden utilities. RAMING BEHIND DRYWALL Construct wood wall framing that is flush with surface of wall studs. Wood wall framing must be at least 1/2” thick and 3” high. Ensure to assemble wood wall framing to wall studs for a solid installation.
  • Page 9 11. REINSTALL BLOWER (HORIZONTAL DISCHARGE ONLY) Position the blower on the higher (A) or lower (B) back wall discharge as determined previously. Using a 5/16” socket, or a Robertson or a Phillips no. 2 screwdriver and the 4 previously removed screws, secure the IGHT SIDE blower to the hood.
  • Page 10 13. INSTALL 8” ADAPTER/DAMPER (VERTICAL DISCHARGE AND NON-DUCTED INSTALLATION ONLY) Mount the 8” round adapter/damper (included in a separate box) to the hood using 4 no. 8 x 3/8” sheet metal screws (included). HJ0038 14. DUCT CONNECTION (VERTICAL DISCHARGE AND NON-DUCTED INSTALLATION ONLY) ERTICAL DISCHAGE Plug hood power cord into the outlet.
  • Page 11 15. PREPARE DECORATIVE FLUE (ALL INSTALLATIONS) UCTED INSTALLATION OUVERS Remove protective plastic film covering the lower flue only. Peel off both corners at the top of the upper flue. Position the lower flue rear notches down (the ones with the 45° angle). Gently slide upper flue inside lower flue, louvers end first (so that louvers are hidden inside lower flue, as they are not needed for the ducted installation).
  • Page 12 16. INSTALL DECORATIVE FLUE (ALL INSTALLATIONS) (CONT'D) PPER FLUE MOUNTING BRACKET RONT VIEW UCTED INSTALLATION PPER Slide up the upper flue until it is aligned with its mounting bracket. The bracket must be FLUE inside the flue. Secure the upper flue to its bracket using 2 no. 8 x 3/8” screws (included). See illustration beside.
  • Page 13: Reinstall Grease Filters

    18. REINSTALL GREASE FILTERS Using a Phillips no. 2 screwdriver, assemble the knob to each filter. The screw MUST BE on same end than filter tabs. See illustration beside. HO0139 Rest rear filters edge on filter springs in the range hood. Using knob, tilt up the filters into position.
  • Page 14: Operation

    20. CARE (CONT'D) Hood cleaning Don’t: • Regularly wash with clean cloth or rag soaked with warm water • Use any steel or stainless steel wool or any other scrapers to and mild soap or liquid dish detergent. remove stubborn dirt. •...
  • Page 15: Wiring Diagram

    To contact Venmar Ventilation ULC warranty service call 1-800-567-3855 in Canada. In order to qualify for a warranty claim, the owner of a Venmar Connaisseur CC32I Series range hood must have the model and serial number along with a proof of the original purchase date.
  • Page 16: Service Parts

    Any third party replacement part used may cause serious damage and drastically reduce the performance level of your unit, which will result in premature failing. Venmar Ventilation recommends to contact a certified service depot for all replacement parts and repairs.