as DIN VDE 0100, DIN 1988, EN 806, DIN 4109, DIN 44851.
!
room free from the risk of frost, as water residues remain inside the device.
Water installation:
Steel, copper or plastic pipework.
Copper or plastic pipework*.
* The instantaneous water heater can reach operating temperatures up to 60 °C. In case of faults, loads
up to 95 °C / 1.2 MPa can occur temporarily in the installation. Any plastic pipework used must be suitable
for these conditions.
The maximum permitted inlet temperature is 60 °C.
The equipment may be damaged at higher temperatures. The maximum inlet temperature can be limited to 60 °C
with the "central thermostat" special accessory (see "Special accessories").
Electrical installation:
disconnect all poles with at least 3 mm contact separation.
(
20).
A
For contractors