Operation Method
Flash
Real-time Power
Calculate Energy
Information
Output Voltage
Output Frequency
Output Current
PV Input Voltage
PV Input Current
Isolation Fault
Leakage Detecting
Grid Fault
No Utility
Fan Fault
PV Over Voltage
Consistent Fault
Relay Failure
DC INJ High
EEPROM Failure
SCI Failure
High DC Bus
28
Flash
Checking Parameters
Pac=xxxxW
Etotal=xxxxkwh
Vac=xxx.xV
Freq.= xx.xHz
Iac=xx.xA
Vpv= xxxV
Idc= xxx A
Fault Information
Isolation Fault
Ground I Fault
Fault OVR
Fault UVR
Fault OFR
Fault UFR
No Utility
Fan Fault
PV Over Voltage
t
Consistent Faul
Relay Failure
DC INJ High
EEPROM Failure
SCI Failure
High DC Bus
Upgrading software
Real-time output power
Total energy feedback to grid
Output voltage
Output frequency
Output Current
PV input voltage
PV input current
Grounding fault or surge voltage
protection failure
Leakage current over rating
AC Over voltage rating
AC Under voltage rating
AC Over frequency rating
AC Under frequency rating
No Utility
Fan locked or circuit fault
PV voltage ≥ Max.DC voltage
CPU or other circuitry failure
Relay is failure between grid and
inverters
DC injection in AC output over rated
value.
EEPROM's failure
MCU internal communication failure
DC bus voltage is higher than the set