Do you have a question about the SolarRiver 3400TL-D and is the answer not in the manual?
Questions and answers
Peter Clark
March 14, 2025
inverter 5200TL-D - Serial No. SW51296420 Don't have a serial number to connect to Wi-Fi. Could you please help.
1 comments:
Mr. Anderson
March 14, 2025
To connect the Samil Power SolarRiver 3400TL-D inverter to Wi-Fi, follow these steps:
1. Connect an Ethernet Cable: Follow the Ethernet connection steps before opening "SolarPower Browser." 2. Open SolarPower Browser: Double-click the inverter name to enter the detailed information page. 3. Set Wi-Fi Parameters: Enter the SSID of the router you want to connect to and input the password. 4. Save Settings: Save the Wi-Fi information. 5. Reboot the Computer: The system will automatically restart and disconnect the Ethernet cable. 6. Verify Wi-Fi Connection: Navigate to Main Menu -> Settings -> Network to check the Wi-Fi status.
There is no mention of needing a serial number for this process.
This answer is automatically generated
Peter J Clark
March 14, 2025
how to connect to my Inverter WiFi
1 comments:
Mr. Anderson
March 14, 2025
To connect the Samil Power SolarRiver 3400TL-D inverter to WiFi, follow these steps:
1. Connect via Ethernet: First, connect a cable following the Ethernet setup steps. 2. Open SolarPower Browser: Double-click the inverter's name to enter the detailed information page. 3. Set WiFi Details: Enter the SSID of the router and input the password. 4. Save and Reboot: Save the settings and restart the computer. 5. Disconnect Ethernet: Remove the Ethernet cable after rebooting. 6. Verify Connection: Check WiFi settings by navigating to Main Menu -> Settings -> Network.
This setup allows the inverter to connect to the internet via WiFi, enabling remote monitoring.
This answer is automatically generated
Subscribe to Our Youtube Channel
Related Manuals for Samil Power SolarRiver 3400TL-D
Copyright Declaration The copyright of this manual belongs to Samil Power Co., Ltd. Any corporation or individual should not plagiarize, partially copy or fully copy it (including software, etc.), and should not reproduce or distribute it in any form or by any means.
CONTENTS 1 Notes On This Manual ......................5 1.1 Scope Of Validity ........................1.2 Target Group ........................1.3 Important safety information ....................1.4 Symbols Used ........................1.5 Symbols on the Inverter ......................1.6 Important Safety Instructions ....................2 Grid-tied System brief introduction ..................7 3 Introduction of SolarRiver-D series inverter ...............
Page 6
7.2.5 Event list ........................7.2.6 Settings ........................8 Communication and Monitoring ..................8.1 Communication Interface ..................... 8.2 Communication mode ......................8.2.1 Ethernet communication ....................8.2.2 RS485 Communication ....................8.2.3 WIFI communication ....................8.2.4 GPRS communication ....................9 Troubleshooting and maintenance ................... 9.1 Troubleshooting .........................
This manual is an integral part of the inverter. Please read the product manual carefully before installation, operation or maintenance. Keep this product manual for future reference. Scope of Validity This product manual describes the assembly, installation, commissioning, maintenance of the following Samil Power SolarRiver-D series inverters. SolarRiver 3400TL-D SolarRiver 4000TL-D SolarRiver 4500TL-D...
● Before using the SolarRiver-D Series inverter, read all instructions and cautionary markings on the SolarRiver-D Series inverter, and all appropriate sections of this guide. ● Recommend the attachments sold by Samil Power, otherwise may result in a risk of fire, electric shock, or injury to persons.
Grid-tied System brief introduction & Introduction of SolarRiver-D series inverter 2 Grid-tied System brief introduction The SolarRiver-D series inverter is a PV inverter which converts the DC current of a PV generator into AC current and feeds it into the public grid. PV modules Inverter Public grid...
Introduction of SolarRiver-D series inverter Electrical block diagram Electrical block diagram of SolarRiver-D series inverter is as figure2. Inverter DC SPD PV modules Leakage protection AC switch DC switch AC SPD Public grid DC SPD PV modules Figure 2 Electrical block diagram of SolarRiver-D series inverter Principle description Principle description of SolarRiver-D series inverter is as figure3.
Introduction of SolarRiver-D series inverter 3.4 Protection function 【Grounding fault】 SolarRiver-D series inverter is designed as floating connection with PV( positive and negative terminals are not connected to ground ). When there is grounding fault, the inverter will be shut down and display grounding fault.
√ Connect line of communication. 5.2 Packaging list Please check the package list, find out all these in the package. The product on the list are for installation. If find some damage or some missing, please contact Samil Power’s sales. Figure 7 packing table...
Installation Table 1 packing list Project Type Description Remark Equipment PV Grid-tied Inverter 1 unit Bracket 1 pc Installation Kit 1set 1 set for inverters without RS-485 Accessories RJ45 plug 3 sets for inverters with RS-485 cable gland 1 pc AC connector 1 pc DC connector assembly...
Page 15
Installation ● The ambient temperature is out the range of -20°C to +60°C ● The altitude 2,000 m above sea level. ● Prone to be damaged by water. ● Close to corrosive gas or liquid (for example, locations where chemicals are processed or the location where feed lots of poultry).
Installation Installation tools Below tools are needed before installation. Installation steps Step1: Drill holes in the wall with diameter 6mm driller according to the size of bracket. Keep drilling perpendicular to the wall, and don’t shake when drilling to avoid damage to the wall. Then put expansion pipe into the hole, use rubber hammer to tap the pipe into the wall completely.
Page 17
Installation Step2:Put the inverter onto the bracket. Step 3: Use M5 hex key nut to fix the bottom of the inverter. Step4: Lock the inverter and the bracket with lock for safety. (This is optional for users. User can select the lock according to your requirements).
Installation Connections of the PV power system 5.7.1 Announcements Ensure that the DC side is not charged before installation and maintenance. But after DC side discharge for a period of time, the capacitor is still charged, so need to wait for 5 minutes to ensure that the capacitors is discharged. Before the electrical connection, make sure to use opaque material to cover the PV battery or disconnected the breaker of DC side.
Installation Please use PV cable to connect arrays to inverter. From junction box to inverter, voltage drop is about 1-2%. So we suggest the inverter be installed near PV arrays, in order to save cable and reduce DC loss. Note! Please don’t connect the PV positive or negative to ground.
Installation 5.7.4 Assembly steps of AC connector SolarRiver series inverters are designed for single phase grid. Technical data should comply with the rule of local public grid. Table 3 Cable and Micro-breaker rule SolarRiver SolarRiver SolarRiver SolarRiver SolarRiver Model 3400TL-D 4000TL-D 4500TL-D 5000TL-D...
Page 21
Installation This product is equipped with IP66 AC connector. You can connect inverter AC side by yourself. Please see figure 15 for AC connector disassembling guide. Figure 15 AC connector disassembling guide Assembly steps of AC connector are as following: Step1: Put the AC wire through the threaded sleeve and pressure screw.
Installation Step4: Screw down the threaded sleeve. Pressure screw Socket element with threaded sleeve Step5: Screw down the pressure screw. Threaded sleeve Pressure screw Step6: Connect AC connector to inverter. 5.7.5 Grounding Neither positive nor negative could grounding because of no transformer, or it wil break down.
If the inverter shows other fault, please refer to part 9--error table. If the inverter fail, please refer to part 9 --error table. 6.3 interface setting Enter start-up interface after starting inverter, shown as figure17. SAMIL POWER CO., LTD. Inverter type: SolarRiver 5200TL-D S/N:...
Page 24
Run the inverter Step1: language setting Move the cursor to select language, press "OK" to select and press "OK" to confirm. Language English German French Espana Italy Press OK to confirm Note: Language setting is independent to Grid-tied country setting. Step2: Grid-tied country setting Next interface is grid-tied country setting interface.
Page 25
Run the inverter Date/Time YYYY YYYY Left/Right : Move Selection Left/Right : Move Selection Up/Down : Increase/Decrease value Up/Down : Increase/Decrease value Press OK to confirm Step4:Check settings information LCD will display the settings information. Please check the settings information. If setting is wrong, please press the “ESC”...
Operation 7 Operation 7.1 Control and Display Panel Control and Display Panel of SolarRiver inverter is shown as figure 18. Green LED Red LED Home 2012-03-03 10 00 00 Power Today Total 208.4 1.045 Buttons 205.9 49.99 Press Esc to Main Menu So la rR i ver Figure 18 HMI Interface There are 6 buttons: OK, ESC, UP, DOWN, RIGHT, LEFT.
Operation 7.2 Interface setting 7.2.1 home interface Enter home interface automatically after startup (If not the home interface, press “ESC” return to the home interface), as shown in figure19. Home 2012-03-03 10 00 00 Power Today Total 208.4 1.045 205.9 49.99 Press Esc to Main Menu Figure 19 home interface...
Page 28
Operation 7.2.5 Event list Move the cursor to the" Event List" and then press “OK”, the user will see the list of events of inverter. Record 100 event information at most. Press the right or left keys to select events. 7.2.6 Settings Move the cursor to the"...
Communication and Monitoring 8 Communication and Monitoring 8.1 Communication Interface Standard configuration: 1. Ethernet: Transmit the inverter working state such as output voltage, current, frequency, fault information to the PC machine or other monitoring system. Ethernet can achieve multi-inverter wired network at the same time.
Page 30
Communication and Monitoring Parameter setting when using router: Step 1:Enter home interface automatically after startup (If not the home interface, press “ESC” return to the home interface). Home 2012-03-03 10 00 00 Power Today Total 208.4 1.045 205.9 49.99 Press Esc to Main Menu Step 2: Press “ESC”...
Page 31
Communication and Monitoring Step 4: Move the cursor to "network", press "OK" and then enter "Input Password" interface. Input Password 2012-03-03 10 03 10 Please input customer password Please input customer password Left/Right : Move Selection Left/Right : Move Selection Up/Down : Increase/Decrease value Up/Down : Increase/Decrease value Press Esc to Settings...
Page 32
Communication and Monitoring Ethernet 2012-03-03 10 22 23 Auto-IP/DHCP Manud-IP Current mode: Manual-IP Press OK to confirm Ethernet 2012-03-03 10 22 50 Auto-IP/DHCP Manud-IP Current mode: Manual-IP Confirm? Press "OK" twice then will enter "Manual-IP" interface. Press "right" or "left" key to move the cursor to select the figure which need to be modified.
Communication and Monitoring 8.2.2 RS485 Communication RS485 is generally for at most 32 inverters communication at the same time. But the length of communication wire should be≤1200m. You can read and analyse data by PC if the system is equipped with Solar-Log200/500/1000.
Communication and Monitoring The communication cable between inverter and Solar-Log: 1. One side of cable is the same as cable between inverter and inverter, the other side remains 4 colour wires: green white, green, orange white, orange, as shown in figure 25. Figure 25 Connect 4 colour wires to 1,4,5,6 port of Solar-Log.
Page 35
Communication and Monitoring WIFI settings: Note:Appendix is WIFI route list. Step1: Connect a cable following the steps of Ethernet before opening "SolarPower Browser". Step2: Double-click name of inverter to enter detail information page. Set the SSID of router which WIFI is going to be connected to and input the password(known from installation contractor) then save these information.
Communication and Monitoring The GUI bellow tells the WIFI hasn’t been set yet. Wifi 2012-03-03 10 28 10 Link Name: Press ESC to Back If WIFI has been set, shown as following figure. Wifi 2012-03-03 10 28 50 Link Name: BAFFAL0-5D8959 Press ESC to Back Hardware Requirements: router、inverter equipped with WIFI、PC(with...
Page 37
Communication and Monitoring Step3: Double-click name of inverter then enter detail information interface. Set the PIN code, service center number and customer mobile telephone number then save these information. Step4: Reboot the computer automatically. Step5: Check GPRS information: Enter the interface successively: Main Menu->Settings->Network, move the cursor to "GPRS" and press "OK".
Communication and Monitoring & Troubleshooting and maintenance If GPRS setting has been initialised, press "OK" to check the information, shown as following figure. GPRS Message 2012-03-03 10 32 06 1234 Center Number: +8613800510500 Customer Number: +8615000000000 Press OK to have a test! Press ESC to Back 9 Troubleshooting and maintenance 9.1 Troubleshooting...
Page 39
When SolarRiver-D inverter is at fault, the fault information is composed of code, occurring time and fault description. Please contact Samil Power Co.,Ltd for further technical assistance. Please provide detailed installation information and inverter model, serial number and fault information.
Troubleshooting and maintenance & Decommissioning 9.2 Daily maintenance Inverters generally do not need any maintenance or calibration, but ensure air-cooling fin not be covered by any dust or dirties. Inverter cleaning Please use electric drier, soft dry cloth or brush to clean inverters. Water, corrosive chemical substance or intense cleaning agent are not allowed to clean the inverter.
Standard warranty [year] 12 Guarantees Samil Power Co., Ltd offers 5 years warranty service for SolarRiver-D inverter. Warranty period is from the date of installation. But the longest period don’t exceed 66 months from the date of delivering goods. During the warranty period, Samil Power Co., Ltd guarantees normal function of the SolarRiver-D inverter.
Need help?
Do you have a question about the SolarRiver 3400TL-D and is the answer not in the manual?
Questions and answers
inverter 5200TL-D - Serial No. SW51296420 Don't have a serial number to connect to Wi-Fi. Could you please help.
To connect the Samil Power SolarRiver 3400TL-D inverter to Wi-Fi, follow these steps:
1. Connect an Ethernet Cable: Follow the Ethernet connection steps before opening "SolarPower Browser."
2. Open SolarPower Browser: Double-click the inverter name to enter the detailed information page.
3. Set Wi-Fi Parameters: Enter the SSID of the router you want to connect to and input the password.
4. Save Settings: Save the Wi-Fi information.
5. Reboot the Computer: The system will automatically restart and disconnect the Ethernet cable.
6. Verify Wi-Fi Connection: Navigate to Main Menu -> Settings -> Network to check the Wi-Fi status.
There is no mention of needing a serial number for this process.
This answer is automatically generated
how to connect to my Inverter WiFi
To connect the Samil Power SolarRiver 3400TL-D inverter to WiFi, follow these steps:
1. Connect via Ethernet: First, connect a cable following the Ethernet setup steps.
2. Open SolarPower Browser: Double-click the inverter's name to enter the detailed information page.
3. Set WiFi Details: Enter the SSID of the router and input the password.
4. Save and Reboot: Save the settings and restart the computer.
5. Disconnect Ethernet: Remove the Ethernet cable after rebooting.
6. Verify Connection: Check WiFi settings by navigating to Main Menu -> Settings -> Network.
This setup allows the inverter to connect to the internet via WiFi, enabling remote monitoring.
This answer is automatically generated