Step 7. INSTALLING THE LOGS, GLOW-
ING EMBERS AND VOLCANIC STONES
Remove the gas line access plate and gasket
from the provided plastic bag and install them
over the opening, using the provided screws
(4) as shown in Figure 37 .
Refer to Figure 41 and loosen the set screw for
the venturi air shutter. Manually actuate the
air shutter through several cycles. Set the air
shutter to 3/32" before placing the logs.
The logs are packaged in a carton located
within the firebox. One plastic bag of glowing
embers and volcanic stones are located in the
bottom compartment. Refer to the Log Set
Placement Supplement for detailed place-
ment instructions for the logs, glowing em-
bers and volcanic stones.
Proper log and twig placement is critical to
encourage outstanding flame appearance and
prevent sooting. These fires are designed to
provide a rich orange/red glow on the logs.
Placement of the rear log is critical and can
be adjusted to taste. Ensure the bottom of
the rear log is fully seated and pulled as far
forward as the pins will allow. Refer to the
Log Set Placement Supplement for detailed
instructions.
Note: Log setup is by design asymmetric. The
fire is intentionally positioned off center to
provide a natural fire look.
Step 8. CHECKING APPLIANCE OPERATION
With gas line installed run initial system check-
out before closing up the front of the unit.
Follow the pilot lighting instructions pro-
vided in the Care and Operation Instructions.
For piezo ignitor location see Figure 37 on
page 22 (millivolt appliances only).
Note: Lighting Instructions are also found on
the literature tag tied to the gas piping next to
the gas valve. To access the tag, open the
lower control compartment door (Figure 37 on
page 22 ) by pulling the panel forward.
When first lighting the appliance, it will take
a few minutes for the line to purge itself of
air. Once purging is complete, the pilot and
burner will light and operate as indicated in
the instruction manual. Subsequent lighting
of the appliance will not require such purg-
ing. Inspect the pilot flame (remove logs, if
necessary, handling carefully).
Millivolt Appliance Checkout
The pilot flame should be steady, not lifting or
floating. Flame should be blue in color with
traces of orange at the outer edge.
The top 3/8" (10 mm) at the pilot generator
(thermopile) and the top 1/8" min (tip) of the
quick drop out thermocouple should be en-
gulfed in the pilot flame.
The flame should project 1" (25 mm) beyond
the hood at all three ports (Figure 38 ). Re-
place logs if removed for pilot inspection.
To light the burner; turn "ON" the remote wall
switch and rotate the gas valve control knob
counterclockwise to the "ON" position ("ON"
will be at the bottom side of the valve).
MILLIVOLT
Hood
Ignitor Rod
Thermocouple
Pilot
Nozzels
Thermopile
Figure 38
Electronic Appliance Checkout
To light the burner, turn 'ON' the unit mounted
On/Off switch or the optional remote wall
switch. Ensure the ignitor lights the pilot. The
pilot flame should engulf the flame rod as
shown in Figure 39 .
ELECTRONIC
Sensor
Ignitor
Figure 39
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Step 9. INSTALLING THE GLASS DOOR
AND OPTIONAL HOOD
To access the glass door securing latches,
first open the lower control compartment
door ( Figure 40 ) by lifting and pulling the
bottom panel forward.
Retrieve the glass door. Visually inspect the
gasket on the backside of the frame. Gasket
surface must be clean, free of irregularities and
seated firmly.
Position the door in front of the firebox opening
with the bottom of the door held away from the
fireplace (Figure 40 ) . Hook the top flange of
the door frame over the top of the firebox frame.
Let the bottom of the door frame swing gently
in towards the fireplace ensuring that the gas-
ket seats evenly as the door frame draws shut.
Fasten the two latches located underneath the
firebox floor to the door's vee-flange. Close
both the latches securely.
If desired, install the optional hood. Note the
location of the three clips inside the top air
channel above the door. The clips are equally
spaced on the top surface of the air channel
³⁄₈" Min
opening. Use a screwdriver to open the clips
(9 mm)
slightly if needed. Engage the back edge of the
eyebrow into the clips to secure.
Door
Pilot
Assembly
Hood
Gas Line Access Panel
Figure 40 -
INSTALLING THE GLASS DOOR
WARNING: HANDLE THIS GLASS WITH
EXTREME CARE! THE GLASS PANEL IS
SUSCEPTIBLE TO DAMAGE — DO NOT
SCRATCH WHILE HANDLING OR WHILE
RE-INSTALLING THE GLASS DOOR
FRAME.
Blower Access
Plate
Bottom Panel
23