Step 7. Installing Logs; Step 8. Checking Unit Operation; Step 9. Installing Glass Enclosure; Panels - Lennox Elite Series Installation Instructions Manual

B-vent multi-open
Table of Contents

Advertisement

The outside air shutter should be fully open when
the fireplace is in use and completely closed
when the fireplace is not being used. Closing it
when not in use will prevent outside cold air from
entering the dwelling.
Outside Air Control Lever with Stop Behind
Securing Screw
Outside Air Shutter in the
Closed Position
Control Compartment Access Panel
Outside Air Control Lever
and Securing Screw Location
f i r e - p a r t s . c o m
(EBST-2, EBPF-2 and EBCR-2 Units Shown)
Figure 23
Operate the actuator through several cycles
including the closed position. Ensuring proper
operation and freedom of movement. Return
the actuator arm to the closed position.
Step 7. INSTALLING LOGS, VERMICULITE,
DECORATIVE VOLCANIC STONE AND
GLOWING EMBERS
The log set, with one plastic bag of vermicu-
lite, is packaged in a carton located within the
firebox. One plastic bag of glowing embers
and one plastic bag of decorative volcanic
stone is located in the bottom compartment.
Refer to the Homeowner's Care and Operat-
ing Instructions for detailed placement in-
structions for the log set, vermiculite, decora-
tive volcanic stone and glowing embers.
Step 8. CHECKING APPLIANCE OPERATION
With gas line installed run initial system check-
out before closing up the front of the unit.
Follow the pilot lighting instructions provided
in the Homeowner's Care and Operation In-
structions. For piezo ignitor location see Figure
22 on page 12 (millivolt appliances only).
Note: Lighting instructions may also be found
on the pull out lighting instruction labels
attached to the gas control valve.
To access the label, see the procedure on the
previous page described for accessing the gas
control valve.
When first lighting the appliance, it will take
a few minutes for the line to purge itself of
air. Once purging is complete, the pilot and
burner will light and operate as indicated in
the instruction manual. Subsequent lightings
of the appliance will not require such purg-
ing. Inspect the pilot flame (remove logs, if
necessary, handling carefully).
Millivolt Appliance Checkout
The pilot flame should be steady and, not lifting
or floating. Flame should be blue in color with
traces of orange at the outer edge.
The top ³⁄₈" (10 mm) at the pilot generator
(thermopile) and the top ¹⁄₈" min (tip) of the
quick drop out thermocouple should be en-
gulfed in the pilot flame. The flame should
project 1" (25 mm) beyond the hood at all three
ports (Figure 24) .
Replace logs after pilot inspection.
To light the burner; turn "ON" the modesty
panel mounted ON/OFF switch and rotate the
gas valve control knob counterclockwise to
the "ON" position.
Hood
MILLIVOLT
Thermocouple
Pilot
Nozzels
Thermopile
Figure 24
Electronic Appliance Checkout
To light the burner, turn 'ON' the modesty
panel mounted ON/OFF switch and turn the gas
control switch to the "ON" position. Ensure the
ignitor lights the pilot. The pilot flame should
engulf the flame rod as shown in Figure 25 .
ELECTRONIC
3/8 To 1/2 Inch
Proper Flame
(9 mm to 13 mm)
Adjustment
Pilot
Nozzle
Figure 25
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Step 9. INSTALLING GLASS ENCLOSURE

PANELS

1. Visually inspect the gasket on the backside
of the panels. The gasket surface must be
clean, free of irregularities and seated firmly.
2. Position the glass enclosure panel in front
of the firebox opening at a 45 degree angle and
engage the top flange over the lip at the top of
the firebox opening. See Figure 26.
3. Swing the glass enclosure panel down and
back. Ensure the gasket seats evenly as the
panel draws shut. Engage the Vee-flange at
the bottom of the panel with the latch; then
close the latch to secure the panel.
4. After installing the front glass enclosure
panel, reinstall the modesty panel by inserting
the tongues on the left side of it into the slots on
the left side cabinet panel. Swing the right side
of the modesty panel towards the unit. Engage
the hook on the right side of the modesty panel
with the right side cabinet panel slot. Gently
press the bottom right corner of the modesty
panel to engage the snap-fit feature.
(The left and right designations used here
are reversed in EDCR-2 applications.)
5. After reinstalling the modesty panel, reinstall
the bottom control compartment access panel
by inserting the right side locating pin into the
right side cabinet panel and then the left side
Ignitor Rod
spring-loaded pin into the left side cabinet panel.
Lower Compartment Door and Hinge
Modesty Panel
³⁄₈" Min
(9 mm)
Glass
Enclosure
Panel
Latch
Bottom Vee-flange
(Glass Enclosure
Panel Frame)
Figure 26 - Installing the Glass Enclosure Panel
Ground
WARNING: HANDLE THE GLASS WITH EXTREME
Electrode
CARE! TEMPERED GLASS IS SUSCEPTIBLE TO
DAMAGE (SCRATCHES, FOR EXAMPLE) –
Flame Rod
HANDLE GLASS DOOR (GLASS ENCLOSURE
Hot Surface
PANEL) GENTLY WHILE REINSTALLING IT.
Igniter
WARNING: NEVER OPERATE THE APPLI-
ANCE WITHOUT THE FRONT GLASS EN-
CLOSURE PANEL IN PLACE AND SECURE.
Top Flange
(Glass Enclosure
Panel Frame)
Front Glass
Enclosure Panel
Firebox Floor
EBST-2 SHOWN
13