Lennox Elite Series Installation Instructions Manual

Lennox Elite Series Installation Instructions Manual

B-vent multi-open

Advertisement

RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
This appliance may be installed in an aftermar-
ket permanently located, manufactured home
(USA only) or mobile home, where not prohib-
ited by local codes. This appliance is only for
use with the type of gas indicated on the rating
plate. This appliance is not convertible for use
f i r e - p a r t s . c o m
with other gases, unless a certified kit is used.
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline
or other flammable vapors or liquids in the vicin-
ity of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow your gas suppliers
instructions.
• If your gas supplier cannot be reached, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
OTL Report No. 116-F-07-5
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
INSTALLATION
INSTRUCTIONS
B-VENT MULTI-OPEN
ELITE
B-VENTED GAS FIREPLACES
P/N 850,008M REV. H 05/2004
MODELS
M
l i
v i l
t l o
M
o
e d
E
B
S
T
N
M
2 -
E
B
C
R
E
B
S
T
P
M
2 -
E
B
C
R
E
B
P
F
N
M
2 -
E
B
C
L
E
B
P
F
P
M
2 -
E
B
C
L
E
B
B
A
Y
N
M
E
B
B
A
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR
RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU
POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser
d'essence ni d'autre vapeurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout autre
appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une
odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le batiment où
vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service dos incendies.
L'installation et service doit être exécuté par un qualifié
installeur, agence de service ou le fournisseur de gaz.
®
SERIES
s l
E
e l
r t c
n o
c i
N
M
2 -
E
B
S
T
N
E
2 -
E
P
M
2 -
E
B
S
T
P
E
2 -
E
N
M
2 -
E
B
P
F
N
E
2 -
E
P
M
2 -
E
B
P
F
P
E
2 -
E
Y
N
P
E
B
B
A
Y
N
E
M
o
e d
s l
B
C
R
N
E
2 -
B
C
R
P
E
2 -
B
C
L
N
E
2 -
B
C
L
P
E
2 -
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Elite Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Lennox Elite Series

  • Page 1 INSTALLATION INSTRUCTIONS B-VENT MULTI-OPEN ® ELITE SERIES B-VENTED GAS FIREPLACES RETAIN THESE INSTRUCTIONS P/N 850,008M REV. H 05/2004 FOR FUTURE REFERENCE MODELS This appliance may be installed in an aftermar- v i l t l o r t c ket permanently located, manufactured home (USA only) or mobile home, where not prohib- ited by local codes.
  • Page 2: Table Of Contents

    PACKAGING GENERAL INFORMATION TABLE OF CONTENTS The assembled vented gas fireplace is pack- WARNING: THESE FIREPLACES ARE Packaging ........page aged with: VENTED DECORATIVE GAS APPLIANCES. Introduction ........page DO NOT BURN WOOD OR OTHER MATE- 1 -one log set, with one plastic bag of vermicu- General Information ......
  • Page 3 Electronic Models - Ne pas se servir de cet appareil s'il a été plongé WARNING: B-VENT APPLIANCES ARE NOT Electronic models have a fixed rate gas valve. dans l'eau, complètement ou en partie. Appeler DESIGNED TO OPERATE IN NEGATIVELY Input of electronic models is shown in the un technicien qualifié...
  • Page 4: Location

    TYPICAL LOCATIONS *When See-Through (EBST-2) is Corner - Left installed with one side flush Corner - Right with a wall,opposite wall must (EBCL-2) (EBCR-2) n o t e x t e n d b e y o n d e i t h e r viewing side of the fireplace.
  • Page 5: Detailed Installation Steps

    DETAILED INSTALLATION STEPS 6 - Open the latch (located in the center of the Floor Nailing Tabs Secure the fireplace to the floor as shown in unit front opening, under the firebox floor) secur- The appliance is shipped with all gas controls ing the glass enclosure panel.
  • Page 6 60 degrees max. Figure 6 Figure 7 f i r e - p a r t s . c o m FIREPLACE FRAMING SPECIFICATIONS EBPF-2 EBST-2 (Peninsula) (See-Through) Minimum Framing Minimum Framing Stud size is 2 x 4 Stud size is 2 x 4 inches (millimeters) inches (millimeters) Gas Line...
  • Page 7 FIREPLACE FRAMING SPECIFICATIONS CONTINUED EBCR-2 (Corner-Right) Minimum Framing EBCL-2 (Corner-Left) Minimum Framing Stud size is 2 x 4 Stud size is 2 x 4 inches (millimeters) inches (millimeters) Gas Line Center of gas line is 3 in. (76 mm) up from floor. *41¹⁄₂...
  • Page 8: Fireplace Specifications

    FIREPLACE SPECIFICATIONS 20¹⁄₁₆ EBST-2 (See-Through) FINISH WALL BRACKET (510) (Front and back edge of unit top) Figure 13 12 (305) FRAMING SPACERS (13) A - 6 (152) DIA. FLUE OUTLET (Top and Both Sides) B - 8 (203) DIA. FLUE COLLAR DETAIL OF 40¹⁄₈...
  • Page 9 FIREPLACE SPECIFICATIONS CONTINUED 20¹⁄₁₆ EBCL-2 (Corner-Left) (510) A - 6 (152) DIA. FLUE OUTLET Figure 15 B - 8 (203) DIA. FLUE COLLAR 12 (305) DETAIL OF FINISH WALL BRACKET FINISH WALL BRACKET ¹⁄₂ FRAMING SPACERS (Front and left edge of unit top) (13) (Top, Side and Back) ¹⁄₂...
  • Page 10: Step 4. Field Wiring

    FIREPLACE SPECIFICATIONS CONTINUED FINISH WALL BRACKET (Front, back, and left edge of unit top) 20¹⁄₁₆ FRAMING SPACERS (510) (Top and Side) EBBAY (Bay) A - 6 (152) DIA. FLUE OUTLET 12 (305) B - 8 (203) DIA. FLUE COLLAR ¹⁄₂ (13) DETAIL OF FINISH WALL...
  • Page 11: Step 5. Connecting Gas Line

    B. Electronic Wiring IMPORTANT: Ground supply wire must be FIREBOX BOTTOM JUNCTION BOX (also see figure 20 on page 11 ) connected to the green wire attached to OUTLET RECEPTACLE CABINET the outlet receptacle's green ground screw. RIGHT SIDE Note: The electronic appliance must be con- See Figure 20 on page 11 .
  • Page 12: Step 6. Outside Air Kit Installation

    Step 6. Outside Air Kits – Optional outside make- Gas Flex Line Connector up air kits, Model FOAK-4 or FAOK-4LD, may be ³ ₈" NPT ₂ ³ ₈ used with these appliances. Refer to the installa- ¹ ₂" x ³ ₈" Flare Valve Flare Fitting Shut-Off Valve...
  • Page 13: Step 7. Installing Logs

    The outside air shutter should be fully open when Step 9. INSTALLING GLASS ENCLOSURE When first lighting the appliance, it will take the fireplace is in use and completely closed a few minutes for the line to purge itself of PANELS when the fireplace is not being used.
  • Page 14: Step 10. Burner Adjustment

    Step 10. BURNER ADJUSTMENTS Manually-Reset Safety Limit Switch This appliance is equipped with a manually-reset blocked flue safety limit switch. Refer to Figure 28 Note - The air shutter for the burner primary air for its location. If, during appliance operation, the flame goes out (independently of the burner on/ opening is factory-set.
  • Page 15: Step 12. Hood Installation

    Step 12. HOOD INSTALLATION COLD CLIMATE INSULATION All of these appliances must have hoods installed prior to operating on all sides with glass If you live in a cold climate, seal all cracks enclosure panels. around your appliance with noncombustible On all clean face units, slide the hoods into the slots on the lower edges of the radiant panels ( Figure 30 ).
  • Page 16: Gas Conversion Kits

    GAS CONVERSION KITS WARNING: THIS CONVERSION KIT SHALL BE AVERTISSEMENT: CET ÉQUIPEMENT DE CONVERSION INSTALLED BY A QUALIFIED SERVICE AGENCY IN SERA INSTALLÉ PAR UNE AGENCE QUALIFIÉE DE SER- ACCORDANCE WITH THE MANUFACTURER'S IN- VICE CONFORMÉMENT AUX INSTRUCTIONS DU STRUCTIONS AND ALL APPLICABLE CODES AND FABRICANT ET TOUTES EXIGENCES ET CODES REQUIREMENTS OF THE AUTHORIZED AGENCY APPLICABLES DE L'AUTORISÉS AVOIR LA JURIDICTION.
  • Page 17 Inlet Pressure Test Port REAR BURNER Pressure Regulator Manifold FRONT BURNER Pressure Test Port Remove These Components Slotted Figure 32 Spring Adjusting FIREBOX SUBFLOOR Step 5. Attach manometer to the manifold side Screw FRONT OF FIREPLACE pressure test fitting and verify manifold pres- Figure 34 sure reads 3.5 inches water column (0.87 kPa) for natural gas, and 10.0 inches water column...
  • Page 18 All Models Step 9. Reassemble the remaining compo- Kit Catalog No. nents by reversing the procedures outlined in 85L72 and 85L86 Step 8. (Refer to Figure 31) the preceding steps. Use pipe joint compound THIS APPLIANCE HAS BEEN CONVERTED TO: NATURAL GAS or Teflon tape on all pipe fittings before install- A.
  • Page 19 f i r e - p a r t s . c o m NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
  • Page 20 - p a r t s . c o m Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

Table of Contents