Lennox EBVSTNM-B Installation Instructions Manual
Lennox EBVSTNM-B Installation Instructions Manual

Lennox EBVSTNM-B Installation Instructions Manual

Ebvst & ebvpf elite series b-vent gas fireplaces
Hide thumbs Also See for EBVSTNM-B:

Advertisement

P/N 850025M Rev. F 04/2013
This manual is one of a set of two supporting this product.
Refer to P/N 875026M for Care and Operation Instructions.
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 850025CF.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l'appareil.
CONSOMMATEUR : Conservez cette notice pour
consultation ultérieure.
WARNING / AVERTISSEMENT / AVISO
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may
result, causing property damage, personal injury,
or death.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
INSTALLATION INSTRUC TIONS
EBVST & EBVPF
B-Vent Gas Fireplaces
MODELS
MILLIVOLT:
EBVSTNM-B
EBVPFNM-B
Decorative Product: Not for use as a heating appliance.
NOTICE: Fireplace is not to be operated by a thermostat.
UNE SURFACE VITRÉE CHAUDE
PEUT CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d'incindie ou d'explosion ou pour
éviter tout dommage matériel, toute blessure ou la mort.
- Ne pas entreposer ni utilizer d'essence ni d'autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
ELECTRONIC:
EBVSTPM-B
EBVSTNE-B
EBVPFPM-B
EBVPFNE-B
Portland
US
OTL Report No. 116-F-07A-5
EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
USTED DEBE NUNCA
TOCAR EL VIDRIO CALIENTE.
LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EBVSTNM-B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lennox EBVSTNM-B

  • Page 1 MODELS P/N 850025M Rev. F 04/2013 MILLIVOLT: ELECTRONIC: This manual is one of a set of two supporting this product. EBVSTNM-B EBVSTPM-B EBVSTNE-B Refer to P/N 875026M for Care and Operation Instructions. Ce manuel est disponible en francais, simplement EBVPFNM-B...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS PACKAGING WARNING The assembled vented gas fireplace is pack- Packaging .........Page 2 Young children should be care- aged with: Introduction ........Page 2 fully supervised when they are General Information ......Page 2 1 - One log set located within the firebox. in the same room as the appli- Requirements for the 2 - One plastic bag containing the literature...
  • Page 3 These appliances comply with National Safety WARNING WARNING Standards and are tested and listed by OMNI-Test Laboratories, Inc. (Report No. 116-F-07A-5) to Improper installation, adjust- Failure to position the parts in ANSI Z21.50 (in Canada, CSA-2.22), and CAN/ ment, alteration, service or accordance with these diagrams CGA-2.17-M91 in both USA and Canada, as vented gas fireplaces.
  • Page 4: Requirements For The

    Gas Pressure - All Models Orifice Sizes - Sea Level to High Altitude Gas Valve Diagrams (All Models) Tables 2 and 3 show the appliances' inlet and See Figure 1 for Millivolt models and Figure 2 manifold gas pressure requirements: For Electronic Models.
  • Page 5: Cold Climate Insulation

    COLD CLIMATE INSULATION For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level.
  • Page 6: Vent Termination Clearances

    VENT TERMINATION CLEARANCES Vertical Vent Termination Clearances These instructions should be used as a Termination Heights For Vents guideline and do not supersede local codes Above Flat Or Sloped Roofs Ref. NFPA 54 / ANSI Z223.1 in any way. Install venting according to local codes, these instructions, the current National Roof Pitch * Feet...
  • Page 7: Appliance And Vent Clearances

    MINIMUM CLEARANCES TO COMBUSTIBLES Mantel Depth Appliance And Vent Clearances 14 (356) The appliance is approved with zero clearance to combustible materials on all sides (as detailed in Table 5), with the following exception: When 12 (305) inches (millimeters) the unit is installed with one side flush with a wall, the wall on the 10 (254) other side of the unit must not extend beyond the front edge of the unit (see Figure 3).
  • Page 8: Pre-Installation Steps

    PRE-INSTALLATION STEPS TYPICAL INSTALLATION SEQUENCE Step 5. (Page 14) Make connection to gas supply. The typical sequence of installation is outlined Step 6. (Page 15) Install and verify outside Top Radiant below. However, each installation is unique Panel air kit operation. and may result in variations to the steps described.
  • Page 9: Step 1. Framing

    Step 1. FRAMING be supported by them or notched to fit around Position the fireplace within the framing. When them. All construction above the appliance must required, the flanges may be bent 90 degrees by Frame these appliances as illustrated in Figures be self supporting, DO NOT use the appliance for hand or with the assistance of a hammer.
  • Page 10: Fireplace Specifications

    FIREPLACE SPECIFICATIONS 20-1/16 EBVST (See-Through) FINISH WALL BRACKET (510) (Front and back edge of unit top) Inches (millimeters) 12 (305) FRAMING SPACERS (13) A - 6 (152) DIA. FLUE OUTLET (Top and Both Sides) B - 8 (203) DIA. FLUE COLLAR DETAIL OF 40-1/8 FINISH WALL BRACKET...
  • Page 11: Step 2. Routing Gas Line

    Step 2. ROUTING GAS LINE Step 3. INSTALL THE VENT SYSTEM Schedule 40 Black Iron Pipe Route a 1/2" (13 mm) gas line to the left side General Information Inside Diameter (Inches) of the appliance as shown in Figure 13. Gas Schedule 40 Pipe Natural Propane...
  • Page 12: Step 4. Field Wiring

    Step 4. FIELD WIRING Refer to Section A for millivolt appliances and Section B for electronic appliances. The gas valve is set in place and pre-wired at the factory CAUTION on both models. Ground supply lead must be con- A. Millivolt Wiring (See Figure 16) nected to the wire attached to the green ground screw located on the Install Optional Control Switch (OFF/ON wall...
  • Page 13 Refer to the owner’s information WITH LOCAL CODES, IF ANY; IF NONE, FOLLOW THE manual, go to www.lennox.com or call 1-800 manual provided with this appliance. For assistance the low voltage circuit as shown in Figure NATIONAL FUEL GAS CODE, ANSI Z223.1, OR NATURAL...
  • Page 14: Step 5. Connecting Gas Line

    STEP 5. CONNECTING GAS LINE TEST ALL CONNECTIONS FOR GAS LEAKS A. Light the appliance (refer to the lighting (FACTORY AND FIELD): instructions label in the control compartment or in the Care and Operation Instructions Make gas line connections. All codes require a manual).
  • Page 15: Step 6. Outside Air Kit

    Step 6. OUTSIDE AIR KITS NOTE: Do not terminate outside air kit in attic The outside air shutter should be fully open when space under any circumstances. the fireplace is in use and completely closed when the fireplace is not being used. Closing Optional outside make-up air kits, Model CAUTION: NEVER LOCATE INLET WHERE IT it when not in use will prevent outside cold air...
  • Page 16: Step 7. Verifying Appliance Operation

    Step 7. VERIFYING APPLIANCE OPERA- MILLIVOLT Hood Igniter Rod TION Thermocouple Turn on burner and observe the individual tongues of flame on the burner. Make sure all ports are open and producing flame evenly across the burner. If any ports are blocked, or partially blocked, clean out the ports.
  • Page 17: Step 8. Installing Logs

    Step 8. INSTALL VERMICULITE, GLOWING EMBERS AND LOGS NOTE: Turn off all electricity to the appliance before you install vermiculite, embers and logs. DO NOT attempt to install the logs until the appliance installation has been completed, the gas line connected and tested for leaks and the initial burner operation has been checked out.
  • Page 18 EBVPF AND EBVST LOG PLACEMENT Part Number Description Number Log, Corner 55M18 Log, Rear/Left 55M19 Log, Front/Left 55M20 Log, Rear/Right 55M21 Log, Front/Center 55M22 Log, Center/Top 55M23 Catalog Number for the entire log set: 55M04 Log (3) Lays Over Logs 1 And 2 STEP 3 STEP 1...
  • Page 19 EBVPF AND EBVST LOG PLACEMENT (CONTINUED) Part Number Description Number Log, Corner 55M18 Log, Rear/Left 55M19 Log, Front/Left 55M20 Log, Rear/Right 55M21 Log, Front/Center 55M22 Log, Center/Top 55M23 Catalog Number for the entire log set: 55M04 Position The Round End Of Log (6) Position Small End Of Log (6) Against The Notch Of Log (4) Here.
  • Page 20: Step 10. Burner Adjustments

    Step 9. REMOVING AND INSTALLING THE Step 10. BURNER ADJUSTMENTS Removing Glass Enclosure Panel (see Figure 29) GLASS DOOR Flame Appearance and sooting Remove the top louver assembly or radiant Proper flame appearance is a flame which is WARNING panel. blue at the base and becomes yellowish-orange in the body of the flame.
  • Page 21: Step 11. Hood Installation

    Burner Adjustment Procedure WARNING • Air shutter adjustment should only be performed by a quali- fied professional service tech- nician. • Ensure glass enclosure panels are in place and sealed during adjustment. CAUTION • Soot will be produced if the air shutter is closed too much.
  • Page 22: Step 12. Spillage Test/Safety Switch

    Step 12. Spillage Test and Safety Limit Manually-Reset Safety Limit Switch Switch Operation This appliance is equipped with a manually-reset blocked flue safety limit switch. Refer to Figure 33 for its location. If, during appliance operation, the flame goes out (independently of the burner Spillage Test on/off wall switch), it may be due to the operation of this safety limit switch.
  • Page 23: Step 13. Attaching Safety-In-Operation Warnings

    En 3. If you are unable to locate the labels, please call Lennox Hearth Products o al distribuidor de Lennox cas de doute, collez l’étiquette en anglais. Lennox Hearth Products or your nearest Lennox Hearth Products más cercano para recibir etiquetas...
  • Page 24: Gas Conversion Kits

    GAS CONVERSION KITS Natural to Propane Gas Conversion Kit Model No. Unit Type Cat. No. WARNING Millivolt H2198 EBVST / EBVPF This conversion kit shall be installed by a qualified service agency in Electronic H2200 accordance with the manufacturer’s instructions and all applicable codes Propane to Natural Gas Conversion Kit and requirements of the authority having jurisdiction.
  • Page 25 d. Locate the latch at the top of the control Inlet Pressure Test Port compartment. To disengage the latch from the bottom vee-flange of the glass enclosure panel, reach for the handle located towards Pressure Regulator the back of the latch and pull the handle down Manifold toward the front of the unit.
  • Page 26 Figure 40 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.