Summary of Contents for Mighty Mule 500 UL325 SERIES
Page 1
Installation Manual ® E-Z GATE OPENER UL325 SERIES ® E-Z GATE OPENER 1-800-543-GATE (4283) • www.mightymule.com WARNING MOVING GATE Can Cause Injury or Death SINGLE GATE SYSTEM v i n a t e I n j u r y a t h p la y in ll o...
Page 2
The installer and/or user vehicular gates only. The Mighty Mule® Gate Opener is intended for use with vehicular swing gates. The opener can be used in Class I, Class II, Class III and Class IV. Vehicular Gate Opener Class Categories...
Table of Contents PLEASE READ THIS FIRST _______________________________________________________ 1 IMPORTANT SAFETY INFORMATION ____________________________________________ 2 TECHNICAL SPECIFICATIONS ___________________________________________________ 9 BEFORE YOU BEGIN ___________________________________________________________ 10 Check Direction of Gate Swing ___________________________________________________ 10 Check Existing Gate Size and Material _____________________________________________ 10 Check for Proper Gate Installation _________________________________________________ 10 Column Installation Information ___________________________________________________ 11 Items Included _________________________________________________________________ 11 Tools Needed__________________________________________________________________ 12...
350 pounds or exceed 8 feet in length and weigh more the transmitter (or keypad, etc.) again. than 850 pounds (please see Technical Specifications on page 9). The Mighty Mule® E-Z Gate Opener can PLEASE NOTE—If your application requires any of be used on vinyl, aluminum, chain link, farm tube, the following: and wrought iron gates.
Important Safety Information Because automatic gate openers produce high levels manual cannot be completely exhaustive in nature. of force, consumers need to know the potential They do, however, provide an overview of the hazards associated with improperly designed, safe design, installation, and use of this product. installed, and maintained automated gate opener CAREFULLY READ AND FOLLOW ALL systems.
Page 6
Important Safety Information For the Consumer WARNING: To reduce the risk of injury or death: 1. READ AND FOLLOW ALL 2. Make sure the gate has been properly installed INSTRUCTIONS. Failure to meet the and swings freely in both directions. Repair or requirements set forth in the instruction manual replace all worn or damaged gate hardware prior could cause severe injury and/or death, for which...
Page 7
Important Safety Information For the Consumer Entrapment Zones for a proper Pull-To-Open installation: Zone 1 – leading edge of the gate and the fence post. Zone 2 – between the gate and the gate post. Zone 3 – the path of the gate. Zone 4 –...
Page 8
6. KEEP GATES PROPERLY MAINTAINED. the Mighty Mule® web site (www.mighty- mule.com), by contacting GTO, Inc., at 3121 Always turn power to operator OFF before Hartsfield Road, Tallahassee, Florida 32303 performing any maintenance.
Page 9
ENTRAPMENT ALARM (UL 325; 30A.1.1A) The Mighty Mule® 500 Automatic Gate Operator is designed to stop and reverse within 2 seconds when the gate comes in contact with an obstruction. Additionally, these operators are equipped with an audio entrapment alarm which will activate if the unit obstructs twice while opening or closing.
Required Safety Precautions for Gates Install Warning Signs Warning signs alert people of automatic gate operation and are required when installing the Mighty Mule® 500 Automatic Gate Operator. Furthermore, a walk-through gate must be installed if pedestrian traffic is expected near the vehicular gate.
Page 11
Important Safety Information Required Safety Precautions for Gates These warning labels should be found at the locations specified below. If any of them are missing, immediately contact GTO for replacements. Product identification and manual operation instruction label (1) installed on right hand side of control box. ®...
300 mA. A gated diode on the control board prevents battery discharge. • The Gate Capacity Chart shows approximate cycles, per day, you can expect from the Mighty Mule® 500 Automat- ic Gate Operator when powered with a transformer. Actual cycles may vary slightly depending upon the type and condition of gate and installation.
(not recommended for solid surface gates). IMPORTANT: Check for Proper Gate Installation For the Mighty Mule® to work properly, gate must be plumb, level, set in concrete, swing freely and not touch the ground and have good working hinges. A - Level...
Before You Begin Column Installation Information IF THIS OPENER WILL BE USED WITH GATES THAT ARE MOUNTED ON MASONRY, BRICK, OR ROCK (etc.) COLUMNS, READ THE FOLLOWING CAREFULLY BEFORE PROCEEDING A. The simplest solution is to install the opener in a B.
• Some types of installations require u-bolts. Mighty Mule® 5 watt solar panel to trickle charge the battery. See the accessory catalog (Do not use • If the gate is a push-to-open refer to page 16 in both transformer and solar).
Gate Opener Installation Mounting Pull-to-Open Opener to Gate Your Property Assemble post bracket parts. Attach opener to gate bracket and secure with required hardware. Reinforcement and Gate Bracket Mounting Steel Pipe Cut in Half (not supplied) Gate Bracket Gate Bracket Thin Walled Wood or Metal Tube Gate...
Page 17
Gate Opener Installation Mounting Pull-to-Open Opener to Gate Your Property OPEN gate and re-attach opener with clevis pin. Check for level. Secure post pivot bracket to post bracket when clearance is OK Clamp securely. (Step 5) in both open and closed positions. Mark middle of post bracket slots on fence post.
Page 18
Gate Opener Installation Mounting Pull-to-Open Opener to Gate Your Property Attach gate bracket assembly to gate cross support. Attach and secure opener assembly to brackets. Check for level. Adjust post bracket if necessary. Remove bolt excess length on post and gate bracket with hacksaw.
Gate Opener Installation Mounting Push-to-Open Opener to Gate Your Property Bracket FM148 11” Assemble post bracket parts. NOTE: A Push-to-Open Bracket Attach opener to gate bracket and secure with hardware re- FM148 is required for this type of installation (not included). quired.
Page 20
Push-to-Open Installation Mounting Push-to-Open Opener to Gate Your Property CLOSE gate and re-attach opener with clevis pin. Check Secure post pivot bracket to post bracket when clearance is OK (Step 5) in both open and closed positions. for level. Clamp securely. Remove clamps, post, gate brackets, and opener.
Page 21
Push-to-Open Installation Mounting Push-to-Open Opener to Gate Your Property Attach gate bracket assembly to gate cross support. Attach and secure opener assembly to brackets. Check for level. Adjust post bracket if necessary. Remove bolt excess length on post and gate bracket with hacksaw.
Control Box Installation Control Box Installation 4 ’ 3 ’ 3 ’ Remove control box cover. Locate control box mounting area. IMPORTANT: Be sure to mount box at least 3ft from AC power and 3ft off the ground. B l a R e d Mount control box to post or fence using screws.
Control Box Installation Control Box Installation CYCLE SAFETY EXIT SHADOW Correct Wrong Wrong CLOSE EDGE OPEN EDGE CYCLE SAFETY Insert 7 wires into corresponding color terminals. Secure wires in terminals. f usIng optIonal solar panel charger Instead of transformer go to page Important: d o not connect both solar panel and transformer Transformer Wiring Installation...
Page 24
Control Box Installation Transformer Wiring Installation Use PVC conduit from ground up to control box. Cut excess cable/strip 1/2” off 2 wires/twist ends. Attach wires to transformer screw terminals. 10” Feed other end of low voltage wire 10” into box through Insert one wire into each 18VAC terminal.
Control Box Installation Receiver Installation FCC Regulation This device complies with FCC rules Part 15. Operation is subject to the following conditions: 1. This device may not cause harmful interference. 2. This device must accept an interference that may cause undesired operation. ’...
NOTE: A minimum of 5 watts of solar charging power is required for Mighty Mule 500 single gate systems, with a maximum of 30 watts. A second battery (7 amp tractor, auto or deep cycle marine battery) is recommended for solar and/or high traffic applications, if needed.
Page 27
Solar Panel Installation 10” Feed cable 10” into box. Insert RED wire into SOLAR (+) positive terminal and BLACK wire into SOLAR (-) negative terminal. Correct Wrong Wrong Secure with terminal screws. Multiple Panel Installations Solar Panels connect in PARALLEL NOTE: All connections should be weatherproofed using weatherproof splice kits available at hardware and...
Control Box Settings Setting Pull-to-Open (Closed) Gate Limit (for push-to-open go to pg. 16) Press button on opener remote; gate should start closing. Press button With gate in OPEN position, turn control box power ON. on opener remote again when gate is in desired CLOSED position. SOFT START OFF WARNING LEARN...
Control Box Settings Setting Push-to-Open (Open) Gate Limit (for pull-to-open go to pg. 26) CYCLE SAFETY EXIT SHADOW CLOSE EDGE OPEN EDGE With gate in CLOSED position, turn control box power switch Press button on opener remote; gate should start opening. Press but- to ON.
3 seconds.The maximum (turn the pot all the way clockwise) auto close time is 120 seconds. IMPORTANT: For safety reasons the obstructions setting or Stall Force on the Mighty Mule® control board comes from the factory set at MIN (minimum). In many installations this setting will need to be adjusted to overcome the weight and size of the gates.
Page 32
Control Box Settings Setting Personal Transmitter Code AUTO CLOSE TIME STALL FORCE STATUS LEARN RMT SOFT START OFF WARNING LEARN OPEN PULL PUSH MAST LIMIT SLV OPEN DLY. SIMULT. MODE1 MODE2 Go to control box. Press and hold the remote and “LEARN RMT” Replace and secure back cover of the opener remote.
PLEASE NOTE: Contact Sensors, Non-Contact Sensors, and Shadow Loops are not included with the Mighty Mule® 500. NOTE: Refer to the sensor manufacturer’s instructions for information about installing these devices on a vehicular gate. The Mighty Mule® 500 will ONLY accept accessory devices with normally open dry contact output.
Connecting Additional Devices Input Connections NOTE: • All control inputs are dry-contact, normally open, inputs. DO NOT apply external voltage sources to these inputs. • All inputs are connected with respect to COMMON terminal. • The status light will blink once when its corresponding input is activated. COM: Circuit common (reference for all logic input) •...
GTO Photo Beams Mighty Mule Push Button Control Mighty Mule Vehicle Sensor Refer to Vehicle Sensor manual for additional connections. Mighty Mule Keypad NOTE: Connections are for typical applications. There may be additional connection options for applications that are not illustrated here.
Connecting Additional Devices Connecting GTO Automatic Lock CONTROL OUTPUTS POWER LOCK INPUTS GTO 18VOLT TRANSFORMER OR SOLAR Wire from Automatic GTO Lock GTO Lock Connection: GTO Lock: Connect the red and black leads from the lock to the GTO LOCK For use exclusively with GTO Lock (FM143 or FM144).
Troubleshooting Guide If your gate opener does not function properly after it is installed, use this guide before calling the GTO Service Department. Audible Feedback Symptom Diagnosis Check: 1 short beep upon Blown Fuse • Fuse activation Low or Bad Battery •...
Page 38
Visual Feedback Symptom Diagnosis Check: Status (clear) Cycle Terminal Disconnect the push button, keypad, intercom keypad, or any other 1 blink Shorted accessory wired to this terminal. Try the remote. If the remote works, then the problem is the accessory. Status (clear) Safety Terminal Disconnect the loop detector, photo beam, or any other accessory wired...
Repair Service If your Mighty Mule Gate Opener is not operating properly, please follow the steps below: ® 3. If repair or replacement of your gate opener is 1. First use the procedures found in the Maintenance necessary, the Service Department will assign a &...
Page 40
Conversion Chart Converting Metric Units to English Equivalents When You Know Multiply By To Find Symbol centimeters 0.3937 inches in. (or ") meters 3.2808 feet ft. (or ') kilograms 2.2046 pounds lb. (or #) Converting English Units to Metric Equivalents When You Know Multiply By To Find...
Page 41
(sold separately). Pin Lock (FM133) The Pin Lock substitutes for the clevis pin at the front end of the Mighty Mule® gate openers. Helps prevent theft of the operator from the gate, while allowing quick release of the operator.
Page 42
Mighty Mule¨, E-Z Gate¨, GTO¨, are registered trademarks of GTO, Inc. America’s DIY Automatic Gate Openers is a trademark of GTO, Inc. and are the exclusive property of GTO, Inc. (“GTO”). All rights are reserved by GTO, and these marks may not be used, in any for without the prior, written permission of GTO.