Fail Safe Electric Strikes
Fail safe electric strikes are ideal for use on escape routes and areas where safety is the primary concern.
331A
– fail safe electric strike
Fail Safe electric strike suitable for use with nightlatches. Will open even when a sidepressure up to
500 kg is applied. Very high strength, resists 1,300 kg side pressure. Tested to 1 million operations.
Continuously rated, available in 12V and 24V DC versions.
5331A
– fail safe electric strike with microswitch
Fail Safe electric strike suitable for use with nightlatches. Will open even when a sidepressure up to
500 kg is applied. Microswitch monitors latchbolt engagement. Very high strength, resists 1,300 kg
side pressure. Tested to 1 million operations. Continuously rated, available in 12V and 24V DC
versions.
Faceplates
24
for metal and
timber frames
16
for timber frames
(vandal-resistant
model)
13
823
for metal and
for metal or
timber frames
uPVC frames
Used with
non- ASSA locks
The electric strikes listed above
may be used with any of the
faceplates shown, depending on
the door frame material.