Sign In
Upload
Manuals
Brands
Daikin Manuals
Air Conditioner
FDMQ18RVJU
Daikin FDMQ18RVJU Manuals
Manuals and User Guides for Daikin FDMQ18RVJU. We have
10
Daikin FDMQ18RVJU manuals available for free PDF download: Service Manual, Manual, Installation Manual, Operation Manual
Daikin FDMQ18RVJU Service Manual (299 pages)
Multi-Split Type Air Conditioners
Brand:
Daikin
| Category:
Air Conditioner
| Size: 7.27 MB
Table of Contents
Table of Contents
2
Introduction
7
Safety Cautions
8
Warnings and Cautions Regarding Safety of Workers
8
Warnings and Cautions Regarding Safety of Users
10
Icons Used
13
Revision History
14
Part 1 General Information
15
Applicable Models
16
Heat Pump
16
Functions
17
RA Indoor Unit
17
SA Indoor Unit
23
Outdoor Unit
27
Part 2 Specifications
28
Specifications
29
RA Indoor Unit
29
SA Indoor Unit
37
Outdoor Unit
40
Part 3 Printed Circuit Board Connector Wiring Diagram
42
Indoor Unit
43
Ftxr09/12/18Tvjuw(S), Ctxg09/12/18Qvjuw(S)
43
Ctxs07Lvju, Ftxs09/12Lvju
45
Ftxs15/18/24Lvju
47
Fdxs09/12Lvju, Cdxs15/18/24Lvju
49
Fvxs09/12/15/18Nvju
51
Fdmq09/12/15/18/24Rvju
53
Ffq09/12/15/18Q2Vju
55
Sensor Kit for FFQ Series
56
Bryq60A2W(S)
56
Wired Remote Controller
57
Brc1E73
57
Wireless Remote Controller Receiver for FDMQ Series
58
Brc082A43
58
Wireless Remote Controller Kit for FFQ Series
59
Brc082A41W, Brc082A42W(S)
59
Outdoor Unit
60
Part 4 Functions and Control
63
Common Functions
65
Temperature Control
65
Frequency Principle
65
RA Indoor Unit Functions
67
Airflow Direction Control
67
Fan Speed Control for Indoor Unit
70
Program Dry Operation
71
Automatic Cooling/Heating Changeover
72
Thermostat Control
73
NIGHT SET Mode
74
ECONO Operation
75
2-Area INTELLIGENT EYE Operation
76
INTELLIGENT EYE Operation
78
POWERFUL Operation
79
Multi-Monitor Lamp/Timer Lamp
80
Clock Setting
81
WEEKLY TIMER Operation
82
Other Functions
88
SA Indoor Unit Functions
90
Airflow Direction Control
90
Fan Speed Control for Indoor Unit
91
Program Dry Operation
92
Clock and Calendar Setting (with Wired Remote Controller BRC1E73)
93
Schedule TIMER Operation (with Wired Remote Controller BRC1E73)
95
Setback Function (with Wired Remote Controller BRC1E73)
99
Drain Pump Control
100
Hot Start Control (in Heating Operation Only)
102
Presence and Floor Sensors (Option)
103
Other Functions
106
Control Specification
108
Thermistor Functions
108
Mode Hierarchy
110
Frequency Control
111
Controls at Mode Changing/Start-Up
113
Discharge Pipe Temperature Control
115
Input Current Control
116
Freeze-Up Protection Control
117
Heating Peak-Cut Control
119
Outdoor Fan Control
120
Liquid Compression Protection Function
120
Defrost Control
120
Low Hz High Pressure Limit
122
Electronic Expansion Valve Control
122
Malfunctions
127
Part 5 Remote Controller
128
Applicable Remote Controller
129
Arc466A36
130
Arc452A21
132
Arc452A23
134
Arc466A21
136
BRC944B2 Wired Remote Controller
138
BRC1E73 Wired Remote Controller
139
BRC082A43 Wireless Remote Controller
145
BRC082A41W, BRC082A42W(S) Wireless Remote Controller
147
Part 6 Service Diagnosis
149
General Problem Symptoms and Check Items
151
Troubleshooting with LED
152
Indoor Unit
152
Outdoor Unit
155
Service Diagnosis
156
ARC452 Series Wireless Remote Controller
156
ARC466 Series Wireless Remote Controller
159
BRC1E73 Wired Remote Controller
162
BRC082A43, BRC082A41W, BRC082A42W(S) Wireless Remote Controller
164
Code Indication on Remote Controller
168
RA Indoor Unit
168
SA Indoor Unit
168
Outdoor Unit
169
Troubleshooting for RA Indoor Unit
170
Indoor Unit PCB Abnormality
170
Freeze-Up Protection Control/Heating Peak-Cut Control
172
Indoor Fan Motor or Related Abnormality
173
Thermistor or Related Abnormality
178
Front Panel Open/Close Fault
179
Signal Transmission Error (between Indoor Unit and Outdoor Unit)
180
Mismatching of Indoor Unit and Outdoor Unit
183
Troubleshooting for SA Indoor Unit
184
Indoor Unit PCB Abnormality
184
Drain Level Control System Abnormality
185
Indoor Fan Motor or Related Abnormality
186
Indoor Fan PCB Abnormality
191
Humidifier or Related Abnormality
192
Thermistor or Related Abnormality
193
Presence Sensor or Floor Sensor Abnormality
194
Remote Controller Thermistor Abnormality
195
Signal Transmission Error (between Indoor and Outdoor Unit)
196
Signal Transmission Error (between Indoor Unit and Remote Controller)
198
Signal Transmission Error (between MAIN/SUB Remote Controllers)
199
Mismatching of Indoor Unit and Outdoor Unit
200
Troubleshooting for Outdoor Unit
201
Refrigerant Shortage
201
Low-Voltage Detection or Over-Voltage Detection
204
Wiring Error Check Unexecuted
206
Unspecified Voltage (between Indoor Unit and Outdoor Unit), Anti-Icing Control in Other Rooms
207
Anti-Icing Control for Indoor Unit
208
Outdoor Unit PCB Abnormality
210
OL Activation (Compressor Overload)
211
Compressor Lock
214
DC Fan Lock
216
Input Overcurrent Detection
218
Four Way Valve Abnormality
220
Discharge Pipe Temperature Control
222
High Pressure Control in Cooling
223
Compressor Sensor System Abnormality
225
Position Sensor Abnormality
227
Thermistor or Related Abnormality (Outdoor Unit)
230
Electrical Box Temperature Rise
232
Radiation Fin Temperature Rise
233
Output Overcurrent Detection
235
Check
238
Thermistor Resistance Check
238
Indoor Fan Motor Connector Check
239
Hall IC Check
240
Power Supply Waveform Check
241
Electronic Expansion Valve Check
242
Four Way Valve Performance Check
243
Inverter Unit Refrigerant System Check
243
Inverter Analyzer Check
244
Rotation Pulse Check on the Outdoor Unit PCB
246
Installation Condition Check
246
Discharge Pressure Check
247
Outdoor Fan System Check
247
Main Circuit Short Check
248
Capacitor Voltage Check
250
Power Module Check
251
Part 7 Trial Operation and Field Settings
252
Pump down Operation
253
Forced Cooling Operation
254
Wiring Error Check Function
255
Trial Operation
257
RA Indoor Unit
257
SA Indoor Unit
259
Field Settings
262
RA Indoor Unit
262
SA Indoor Unit
268
Outdoor Unit
280
Silicone Grease on Power Transistor/Diode Bridge
283
Part 8 Appendix
284
Piping Diagrams
285
Indoor Unit
285
Outdoor Unit
288
Wiring Diagrams
289
Indoor Unit
289
Outdoor Unit
296
Operation Limit
298
Advertisement
Daikin FDMQ18RVJU Service Manual (282 pages)
Multi-Split Type Air Conditioners
Brand:
Daikin
| Category:
Air Conditioner
| Size: 14.64 MB
Table of Contents
Table of Contents
3
Safety Cautions
8
Warnings and Cautions Regarding Safety of Workers
8
Warnings and Cautions Regarding Safety of Users
10
Icons Used
13
Part 1 List of Functions
14
RA Indoor Unit
15
SA Indoor Unit
20
Outdoor Unit
22
Part 2 Specifications
23
RA Indoor Unit
24
SA Indoor Unit
32
Outdoor Unit
35
Part 3 Printed Circuit Board Connector Wiring Diagram
38
Indoor Unit
39
Ctxg09/12/18Qvjuw(S), Ftxr09/12/18Tvjuw(S)
39
Ctxs07Lvju, Ftxs09/12Lvju
41
Ftxs15/18/24Lvju
43
Cdxs07/15/18/24Lvju, Fdxs09/12Lvju
45
Fvxs09/12/15/18Nvju
47
Fdmq09/12/15/18/24Rvju
49
Ffq09/12/15/18Q2Vju
51
Sensor Kit for FFQ Series
52
Bryq60A2W(S)
52
Wired Remote Controller
53
Brc1E73
53
Wireless Remote Controller Receiver for FDMQ Series
54
Brc082A43
54
Wireless Remote Controller Kit for FFQ Series
55
Brc082A41W, Brc082A42W(S)
55
Outdoor Unit
56
Part 4 Functions and Control
59
Common Functions
61
Temperature Control
61
Frequency Principle
61
RA Indoor Unit Functions
63
Airflow Direction Control
63
Fan Speed Control for Indoor Unit
67
Program Dry Operation
68
Automatic Operation
69
Thermostat Control
70
NIGHT SET Mode
71
ECONO Operation
72
2-Area INTELLIGENT EYE Operation
73
INTELLIGENT EYE Operation
75
POWERFUL Operation
76
Multi-Monitor Lamp/Timer Lamp
77
Clock Setting
78
WEEKLY TIMER Operation
79
Other Functions
85
SA Indoor Unit Functions
87
Airflow Direction Control
87
Fan Speed Control for Indoor Unit
88
Program Dry Operation
89
Clock and Calendar Setting (with Wired Remote Controller BRC1E73)
90
Schedule TIMER Operation (with Wired Remote Controller BRC1E73)
92
Setback Function (with Wired Remote Controller BRC1E73)
96
Drain Pump Control
96
Hot Start Control (in Heating Operation Only)
98
Presence and Floor Sensors (Option)
99
Other Functions
102
Control Specification
103
Thermistor Functions
103
Mode Hierarchy
105
Frequency Control
106
Controls at Mode Changing/Start-Up
108
Discharge Pipe Temperature Control
109
Input Current Control
110
Freeze-Up Protection Control
111
Heating Peak-Cut Control
113
Outdoor Fan Control
114
Liquid Compression Protection Function
114
Defrost Control
115
Low Hz High Pressure Limit
116
Electronic Expansion Valve Control
117
Malfunctions
122
Part 5 Remote Controller
123
Applicable Remote Controller
124
Arc466A36
125
Arc452A21
127
Arc452A23
129
Arc466A21
131
Wired Remote Controller (BRC944B2)
133
Wired Remote Controller (BRC1E73)
134
Wireless Remote Controller (BRC082A43)
140
Wireless Remote Controller (BRC082A41W, BRC082A42W(S))
142
Part 6 Service Diagnosis
144
General Problem Symptoms and Check Items
146
Troubleshooting with LED
147
Indoor Unit
147
Outdoor Unit
149
Service Diagnosis
150
RA Indoor Unit
150
SA Indoor Unit
156
Code Indication on Remote Controller
162
RA Indoor Unit
162
SA Indoor Unit
162
Outdoor Unit
163
Troubleshooting for RA Indoor Unit
164
Indoor Unit PCB Abnormality
164
Freeze-Up Protection Control, Heating Peak-Cut Control
166
Indoor Fan Motor or Related Abnormality
167
Thermistor or Related Abnormality
171
Front Panel Open/Close Fault
172
Signal Transmission Error (between Indoor Unit and Outdoor Unit)
173
Mismatching of Indoor Unit and Outdoor Unit
175
Troubleshooting for SA Indoor Unit
176
Indoor Unit PCB Abnormality
176
Drain Level Control System Abnormality
177
Indoor Fan Motor or Related Abnormality
178
Indoor Fan PCB Abnormality
182
Humidifier or Related Abnormality
183
Thermistor or Related Abnormality
184
Presence Sensor or Floor Sensor Abnormality
185
Remote Controller Thermistor Abnormality
186
Signal Transmission Error (between Indoor Unit and Outdoor Unit)
187
Signal Transmission Error (between Indoor Unit and Remote Controller)
189
Signal Transmission Error
189
(Between Indoor Unit and Remote Controller)
189
Signal Transmission Error (between MAIN Remote Controller and SUB Remote Controller)
190
Mismatching of Indoor Unit and Outdoor Unit
191
Troubleshooting for Outdoor Unit
192
Refrigerant Shortage
192
Low-Voltage Detection or Over-Voltage Detection
194
Wiring Error Check Unexecuted
196
Unspecified Voltage (between Indoor Unit and Outdoor Unit), Anti-Icing Control in Other Rooms
197
Anti-Icing Control for Indoor Unit
198
Outdoor Unit PCB Abnormality
200
OL Activation (Compressor Overload)
201
Compressor Lock
203
DC Fan Lock
204
Input Overcurrent Detection
205
Four Way Valve Abnormality
206
Discharge Pipe Temperature Control
208
High Pressure Control in Cooling
209
Compressor Sensor System Abnormality
210
Position Sensor Abnormality
212
CT or Related Abnormality
214
Thermistor or Related Abnormality (Outdoor Unit)
216
Electrical Box Temperature Rise
218
Radiation Fin Temperature Rise
219
Output Overcurrent Detection
220
Check
222
Thermistor Resistance Check
222
Indoor Fan Motor Connector Check
223
Hall IC Check
224
Power Supply Waveform Check
224
Electronic Expansion Valve Check
225
Four Way Valve Performance Check
226
Inverter Unit Refrigerant System Check
226
Inverter Analyzer Check
227
Rotation Pulse Check on the Outdoor Unit PCB
228
Installation Condition Check
229
Discharge Pressure Check
229
Outdoor Fan System Check
230
Main Circuit Short Check
230
Capacitor Voltage Check
231
Power Module Check
232
Part 7 Trial Operation and Field Settings
233
Pump down Operation
234
Forced Cooling Operation
235
Wiring Error Check Function
236
Trial Operation
238
RA Indoor Unit
238
SA Indoor Unit
240
Field Settings
243
Outdoor Unit
243
RA Indoor Unit
245
SA Indoor Unit
250
Silicone Grease on Power Transistor/Diode Bridge
262
Part 8 Appendix
263
Piping Diagrams
264
Indoor Unit
264
Outdoor Unit
267
Wiring Diagrams
269
Indoor Unit
269
Outdoor Unit
276
Operation Limit
280
Daikin FDMQ18RVJU Service Manual (242 pages)
Inverter Pair: Wall Mounted Type, Floor Standing Type, Duct Connected Type.
Brand:
Daikin
| Category:
Air Conditioner
| Size: 23.96 MB
Table of Contents
Table of Contents
2
Introduction
6
Safety Cautions
7
Warnings and Cautions Regarding Safety of Workers
7
Warnings and Cautions Regarding Safety of Users
9
Icons Used
12
Revision History
13
Part 1 General Information
14
Applicable Models
15
Functions
16
Part 2 Specifications
18
Specifications
19
Part 3 Printed Circuit Board Connector Wiring Diagram
26
Indoor Unit
27
Ftx09/12Nmvju
27
Ftx15Nmvju
29
Ftx18/24Uvju
31
Fvxs09/12/15Nvju
33
Fdmq12/18/24Rvju
35
Wireless Remote Controller Receiver
37
Brc082A43
37
Wired Remote Controller
38
Brc1E73
38
Outdoor Unit
39
Rxl09Qmvju
39
Rxl12Qmvju(9)
41
Rxl15Qmvju
43
Rxl18/24Umvju
44
Optional Adaptor
47
BRP072A43 Wireless LAN Adaptor
47
KRP067A41/KRP980B2 Remote Control PC-Board Set
47
Part 4 Functions and Control
48
Common Functions
49
Temperature Control
49
Frequency Principle
49
Functions for FTX, FVXS Series
51
Airflow Direction Control
51
COMFORT AIRFLOW Operation
54
Fan Speed Control for Indoor Unit
55
Program Dry Operation
56
Automatic Cooling/Heating Changeover
57
Thermostat Control
58
NIGHT SET Mode
59
ECONO Operation
60
INTELLIGENT EYE Operation
61
POWERFUL Operation
62
Clock Setting
63
WEEKLY TIMER Operation
64
Other Functions
70
Functions for FDMQ Series
71
Fan Speed Control for Indoor Unit
71
Program Dry Operation
72
Clock and Calender Setting (with BRC1E73)
73
Schedule Timer Operation (with BRC1E73)
75
Drain Pump Control
78
Hot Start Control (in Heating Operation Only)
80
Other Functions
81
Thermistor Functions
82
Control Specification
83
Mode Hierarchy
83
Frequency Control
83
Controls at Mode Changing/Start-Up
85
Discharge Pipe Temperature Control
87
Input Current Control
88
Freeze-Up Protection Control
89
Heating Peak-Cut Control
89
Outdoor Fan Control
90
Liquid Compression Protection Function
90
Defrost Control
91
Electronic Expansion Valve Control
92
Malfunctions
95
Part 5 Remote Controller
96
Applicable Remote Controller
97
Arc466A21
98
Arc466A37
100
Arc480A8
102
Brc082A43
103
Brc1E73
105
Part 6 Service Diagnosis
111
General Problem Symptoms and Check Items
113
Troubleshooting with LED
114
Indoor Unit
114
Outdoor Unit
115
Service Diagnosis
116
ARC480 Series
116
ARC466 Series
119
Brc1E73
122
Brc082A43
124
Error Codes and Description
128
Troubleshooting for FTX, FVXS Series
129
Indoor Unit PCB Abnormality
129
Freeze-Up Protection Control/Heating Peak-Cut Control
131
Indoor Fan Motor (DC Motor) or Related Abnormality
133
Thermistor or Related Abnormality
137
Low-Voltage Detection or Over-Voltage Detection
138
Signal Transmission Error (between Indoor Unit and Outdoor Unit)
140
Unspecified Voltage (between Indoor Unit and Outdoor Unit)
142
Troubleshooting for FDMQ Series
143
Indoor Unit PCB Abnormality
143
Drain Level Control System Abnormality
144
Indoor Fan Motor (DC Motor) or Related Abnormality
145
Indoor Fan PCB Abnormality
147
Humidifier or Related Abnormality
148
Thermistor or Related Abnormality
149
Remote Controller Thermistor Abnormality
150
Low-Voltage Detection or Over-Voltage Detection
151
Signal Transmission Error (between Indoor and Outdoor Unit)
153
Signal Transmission Error (between Indoor Unit and Remote Controller)
155
Signal Transmission Error (between MAIN/SUB Remote Controllers)
156
Mismatching of Indoor Unit and Outdoor Unit
157
Troubleshooting for Outdoor Unit
158
Outdoor Unit PCB Abnormality
158
OL Activation (Compressor Overload)
159
Compressor Lock
162
DC Fan Lock
163
Input Overcurrent Detection
164
Four Way Valve Abnormality
166
Discharge Pipe Temperature Control
168
High Pressure Control in Cooling
170
System Shutdown Due to Temperature Abnormality in the Compressor
172
Compressor Sensor System Abnormality
173
Position Sensor Abnormality
174
Thermistor or Related Abnormality (Outdoor Unit)
177
Electrical Box Temperature Rise
179
Radiation Fin Temperature Rise
181
Output Overcurrent Detection
183
Signal Transmission Error on Outdoor Unit PCB
185
Check
186
Thermistor Resistance Check
186
Indoor Fan Motor Connector Check
187
Power Supply Waveform Check
189
Electronic Expansion Valve Check
189
Four Way Valve Performance Check
190
Inverter Unit Refrigerant System Check
190
Inverter Analyzer Check
191
Rotation Pulse Check on the Outdoor Unit PCB
194
Installation Condition Check
195
Discharge Pressure Check
195
Outdoor Fan System Check
196
Main Circuit Short Check
196
Power Module Check
199
Part 7 Trial Operation and Field Settings
202
Pump down Operation
203
Forced Cooling Operation
204
Trial Operation
207
Field Settings for FTX, FVXS Series
211
Temperature Display Switch
211
When 2 Units Are Installed in 1 Room
212
Jumper and Switch Settings
214
Field Settings for FDMQ Series
215
How to Change the Field Settings
215
Overview of Field Settings
218
MAIN/SUB and Address Setting for Wireless Remote Controller
219
Field Settings for Outdoor Unit
222
Facility Setting (Cooling at Low Outdoor Temperature)
222
Drain Pan Heater
223
Silicone Grease on Power Transistor/Diode Bridge
224
Part 8 Appendix
225
Piping Diagrams
226
Indoor Unit
226
Outdoor Unit
228
Wiring Diagrams
231
Indoor Unit
231
Outdoor Unit
236
Operation Limit
241
Advertisement
Daikin FDMQ18RVJU Manual (152 pages)
Inverter Pair Duct Connected Type
Brand:
Daikin
| Category:
Inverter
| Size: 4.48 MB
Table of Contents
Table of Contents
3
Safety Cautions
6
Warnings and Cautions Regarding Safety of Workers
6
Warnings and Cautions Regarding Safety of Users
8
Icons Used
11
Part 1 List of Functions
12
Functions
13
Part 2 Specifications
14
Specifications
15
Part 3 Printed Circuit Board Connector Wiring Diagram
20
Indoor Unit
21
Fdmq09/12/15/18/24Rvju
21
Wired Remote Controller
23
Brc1E73
23
Wireless Remote Controller Receiver
24
Brc082A43
24
Outdoor Unit
25
Rx09/12R
25
Rx15/18/24R
26
Part 4 Functions and Control
27
Main Functions
28
Temperature Control
28
Frequency Principle
28
Fan Speed Control for Indoor Unit
30
Program Dry Operation
31
Clock and Calendar Setting (with Wired Remote Controller BRC1E73)
32
Schedule TIMER Operation (with Wired Remote Controller BRC1E73)
34
Drain Pump Control
37
Hot Start Control (in Heating Operation Only)
39
Other Functions
40
Control Specification
41
Mode Hierarchy
41
Frequency Control
42
Controls at Mode Changing/Start-Up
44
Discharge Pipe Temperature Control
46
Input Current Control
47
Freeze-Up Protection Control
48
Heating Peak-Cut Control
49
Outdoor Fan Control
50
Liquid Compression Protection Function
50
Defrost Control
51
Electronic Expansion Valve Control
52
Malfunctions
55
Part 5 Remote Controller
56
Wired Remote Controller (BRC1E73)
57
Wireless Remote Controller (BRC082A43)
63
Part 6 Service Diagnosis
65
General Problem Symptoms and Check Items
67
Troubleshooting with LED
68
Indoor Unit
68
Outdoor Unit
68
Service Diagnosis
69
Wired Remote Controller (BRC1E73)
69
Wireless Remote Controller (BRC082A43)
71
Troubleshooting
75
Error Codes and Description
75
Indoor Unit PCB Abnormality
76
Drain Level Control System Abnormality
77
Indoor Fan Motor (DC Motor) or Related Abnormality
78
Indoor Fan PCB Abnormality
80
Humidifier or Related Abnormality
81
Thermistor or Related Abnormality
82
Remote Controller Thermistor Abnormality
83
Signal Transmission Error (between Indoor Unit and Remote Controller)
84
Signal Transmission Error (between MAIN Remote Controller and SUB Remote Controller)
85
Low-Voltage Detection or Over-Voltage Detection
86
Signal Transmission Error (between Indoor Unit and Outdoor Unit)
88
Mismatching of Indoor Unit and Outdoor Unit
90
Outdoor Unit PCB Abnormality
91
OL Activation (Compressor Overload)
92
OL Activation (Compressor Overload) or HPS Activation (High Pressure Switch)
94
Compressor Lock
97
DC Fan Lock (Outdoor Fan Motor)
98
Input Overcurrent Detection
99
Four Way Valve Abnormality
100
Discharge Pipe Temperature Control
102
High Pressure Control in Cooling
103
System Shutdown Due to Temperature Abnormality in Compressor
105
Compressor System Sensor Abnormality
106
Position Sensor Abnormality
107
DC Voltage/Current Sensor Abnormality
109
Thermistor or Related Abnormality (Outdoor Unit)
110
Electrical Box Temperature Rise
112
Radiation Fin Temperature Rise
113
Output Overcurrent Detection
114
Check
116
Thermistor Resistance Check
116
Indoor Fan Motor Connector Check
117
Power Supply Waveforms Check
117
Electronic Expansion Valve Check
118
Four Way Valve Performance Check
119
Inverter Unit Refrigerant System Check
119
Inverter Analyzer Check
120
Outdoor Fan Motor Check
122
Installation Condition Check
123
Discharge Pressure Check
123
Outdoor Fan System Check
124
Main Circuit Short Check
124
Power Module Check
126
Part 7 Trial Operation and Field Settings
128
Pump down Operation
129
Forced Cooling Operation
130
Trial Operation
131
Field Settings
134
How to Change the Field Settings
134
Overview of the Field Settings
137
MAIN/SUB and Address Setting for Wireless Remote Controller
138
Facility Setting (Cooling at Low Outdoor Temperature)
140
Silicone Grease on Power Transistor/Diode Bridge
141
Part 8 Appendix
142
Piping Diagrams
143
Indoor Unit
143
Outdoor Unit
144
Wiring Diagrams
146
Indoor Unit
146
Outdoor Unit
147
Operation Limit
150
Daikin FDMQ18RVJU Service Manual (146 pages)
Inverter Pair Duct Connected Type
Brand:
Daikin
| Category:
Inverter
| Size: 3.65 MB
Table of Contents
Table of Contents
3
Safety Cautions
6
Warnings and Cautions Regarding Safety of Workers
6
Warnings and Cautions Regarding Safety of Users
8
Icons Used
11
Part 1 List of Functions
12
Functions
13
Part 2 Specifications
14
Specifications
15
Part 3 Printed Circuit Board Connector Wiring Diagram
19
Indoor Unit
20
Fdmq09/12/15/18/24Rvju
20
Wired Remote Controller
22
Brc1E73
22
Wireless Remote Controller Receiver
23
Brc082A43
23
Outdoor Unit
24
Rx09/12Rmvju(9)
24
Rx15/24Rmvju(A), Rx18Rmvju(9)(A)
25
Part 4 Functions and Control
26
Main Functions
27
Temperature Control
27
Frequency Principle
27
Fan Speed Control for Indoor Unit
29
Program Dry Operation
30
Clock and Calendar Setting (with Wired Remote Controller BRC1E73)
31
Schedule TIMER Operation (with Wired Remote Controller BRC1E73)
33
Drain Pump Control
36
Hot Start Control (in Heating Operation Only)
38
Other Functions
39
Control Specification
40
Mode Hierarchy
40
Frequency Control
41
Controls at Mode Changing/Start-Up
43
Discharge Pipe Temperature Control
45
Input Current Control
46
Freeze-Up Protection Control
47
Heating Peak-Cut Control
48
Outdoor Fan Control
49
Liquid Compression Protection Function
49
Defrost Control
50
Electronic Expansion Valve Control
51
Malfunctions
54
Part 5 Remote Controller
55
Wired Remote Controller (BRC1E73)
56
Wireless Remote Controller (BRC082A43)
62
Part 6 Service Diagnosis
64
General Problem Symptoms and Check Items
66
Troubleshooting with LED
67
Indoor Unit
67
Outdoor Unit
67
Service Diagnosis
68
Wired Remote Controller (BRC1E73)
68
Wireless Remote Controller (BRC082A43)
70
Troubleshooting
74
Error Codes and Description
74
Indoor Unit PCB Abnormality
75
Drain Level Control System Abnormality
76
Indoor Fan Motor (DC Motor) or Related Abnormality
77
Indoor Fan PCB Abnormality
79
Humidifier or Related Abnormality
80
Thermistor or Related Abnormality
81
Remote Controller Thermistor Abnormality
82
Signal Transmission Error (between Indoor Unit and Remote Controller)
83
Signal Transmission Error (between MAIN Remote Controller and SUB Remote Controller)
84
Signal Transmission Error
84
(Between MAIN Remote Controller and SUB Remote Controller)
84
Low-Voltage Detection or Over-Voltage Detection
85
Signal Transmission Error (between Indoor Unit and Outdoor Unit)
87
Mismatching of Indoor Unit and Outdoor Unit
89
Outdoor Unit PCB Abnormality
90
OL Activation (Compressor Overload)
91
Compressor Lock
93
DC Fan Lock (Outdoor Fan Motor)
94
Input Overcurrent Detection
95
Four Way Valve Abnormality
96
Discharge Pipe Temperature Control
98
High Pressure Control in Cooling
99
System Shutdown Due to Compressor Internal Temperature Abnormality
101
Compressor System Sensor Abnormality
102
Position Sensor Abnormality
103
Thermistor or Related Abnormality (Outdoor Unit)
105
Electrical Box Temperature Rise
107
Radiation Fin Temperature Rise
108
Output Overcurrent Detection
109
Check
111
Thermistor Resistance Check
111
Indoor Fan Motor Connector Check
112
Power Supply Waveforms Check
112
Electronic Expansion Valve Check
113
Four Way Valve Performance Check
114
Inverter Unit Refrigerant System Check
114
Inverter Analyzer Check
115
Rotation Pulse Check on the Outdoor Unit PCB
117
Installation Condition Check
118
Discharge Pressure Check
118
Outdoor Fan System Check
119
Main Circuit Short Check
119
Power Module Check
121
Part 7 Trial Operation and Field Settings
123
Pump down Operation
124
Forced Cooling Operation
125
Trial Operation
126
Field Settings
129
How to Change the Field Settings
129
Overview of the Field Settings
132
MAIN/SUB and Address Setting for Wireless Remote Controller
133
Facility Setting (Cooling at Low Outdoor Temperature)
135
Silicone Grease on Power Transistor/Diode Bridge
136
Part 8 Appendix
137
Piping Diagrams
138
Indoor Unit
138
Outdoor Unit
139
Wiring Diagrams
141
Indoor Unit
141
Outdoor Unit
142
Operation Limit
144
daikin FDMQ18RVJU Installation Manual (22 pages)
R410A Split Series
Brand:
daikin
| Category:
Air Conditioner
| Size: 7.1 MB
Table of Contents
Installation Manual
1
Table of Contents
2
Safety Considerations
2
Before Installation
4
Optional Accessories
4
Choosing an Installation Site
5
Preparation before Installation
6
Indoor Unit Installation
7
Refrigerant Piping Work
8
Drain Piping Work
10
Duct Work
12
Electric Wiring Work
12
General Instructions
12
Field Setting
15
Trial Operation and Testing
16
Daikin FDMQ18RVJU Service Manual (19 pages)
Brand:
Daikin
| Category:
Air Conditioner Accessories
| Size: 4.58 MB
Table of Contents
Table of Contents
3
Pcbs / Reactor / Terminal Blocks
4
Fan Motor / Fan Rotor
7
Drain Pan
10
Thermistors / Drain Pump / Float Switch
12
Indoor Heat Exchanger
16
Daikin FDMQ18RVJU Service Manual (20 pages)
Inverter Pair Duct Connected Type
Brand:
Daikin
| Category:
Heat Pump
| Size: 1.07 MB
Daikin FDMQ18RVJU Operation Manual (12 pages)
Brand:
Daikin
| Category:
Air Conditioner
| Size: 1.26 MB
Table of Contents
Operation Manual
1
Table of Contents
2
Safety Considerations
4
Names of Parts
5
Note for Multi System
6
Care and Cleaning
8
Air Conditioner
9
Troubleshooting
10
Daikin FDMQ18RVJU Operation Manual (12 pages)
Brand:
Daikin
| Category:
Air Conditioner
| Size: 1.26 MB
Advertisement
Related Products
Daikin FDMQ12RVJU
Daikin FDMQ15RVJU
Daikin FDMQ18RXL
Daikin FDMQ12WVJU9
Daikin FDMQ15WVJU9
Daikin FDMQ18WVJU9
Daikin FDMQ24RVJU
Daikin FDMQ35CXV1
Daikin FDMQ50CXV1
Daikin 19 SERIES
Daikin Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More Daikin Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL