Arc466A36 - Daikin 4MXS-R Series Service Manual

Multi-split type air conditioners
Table of Contents

Advertisement

SiUS121736EA

2. ARC466A36

Signal transmitter
• To use the remote controller, aim the
transmitter at the indoor unit. If there
is anything to block signals between
the unit and the remote controller,
such as a curtain, the unit will not
operate.
• The maximum distance for
communication is about 19-11/16 ft
(6 m).
Make sure that there are no
obstacles within 19-11/16 inch (50
cm) under the signal receiver.
Such obstacles, if any, may have an
adverse influence on the reception
performance of the receiver and the
reception distance may be
shortened.
Fan setting button
• Selects the airflow rate setting.
Auto
Indoor unit quiet
High
Middle high
• In indoor unit quiet operation,
operation sound becomes weak.
(The airflow rate also decreases.)
• In DRY operation, the airflow rate
setting is not available.
Reference
Refer to the following pages for details.
1 POWERFUL operation .......................................................................................................... P.63
Remote Controller
Receiver
19-11/16"
(50 cm)
or more
Low
Middle low
Middle
< ARC466A36 >
Display (LCD)
• Displays the current settings.
(In this illustration, each section is
shown with all its displays on for the
purpose of explanation.)
Temperature adjustment
buttons
• Changes the temperature setting.
18 ~ 30 °C
: AUTO
(64 ~ 86 °F)
: DRY
Not available
18 ~ 32 °C
: COOL
(64 ~ 90 °F)
10 ~ 30 °C
: HEAT
(50 ~ 86 °F)
Not available
: FAN
On/Off button
• Press this button once to start
operation.
Press once again to stop it.
Powerful
1
button
• Starts POWERFUL operation.

ARC466A36

(R24594)
112