7.14 Compressor Sensor System Abnormality

H0
Error Code
j
Outdoor Unit LED
A
Display
Method of Error
Detection
Error Decision
Conditions
Supposed
Causes
197
i
i
h
h
1
2
3
4
The system checks the power supply voltage and the DC voltage before the compressor starts.
The system checks the DC current of the compressor right after the compressor starts.
DC voltage
The power supply voltage and the DC voltage is obviously low or high.
The DC current of the compressor does not flow when the compressor starts.
Disconnection of reactor
Disconnection of compressor harness
Defective outdoor unit PCB
Defective compressor