Ctxs07Lvju, Ftxs09/12Lvju - Daikin 4MXL-T Series Service Manual

Multi-split type air conditioners
Table of Contents

Advertisement

SiUS121827E
1.2

CTXS07LVJU, FTXS09/12LVJU

Control PCB
1)
(PCB1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
12)
13)
14)
S41
S46
S25
JC
JA
S47
Caution
Replace the PCB if you cut a jumper unintentionally.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
Note
The symbols in the parenthesis are the names on the appropriate wiring diagram.
Part 3 Printed Circuit Board Connector Wiring Diagram
S1
Connector for DC fan motor
S21
Connector for centralized control (HA)
S25
Connector for INTELLIGENT EYE sensor PCB (PCB4)
S32
Indoor heat exchanger thermistor
S41
Connector for swing motors
S46
Connector for display PCB (PCB3)
S47
Connector for signal receiver PCB (PCB2)
H1, H2, H3, FG Connector for terminal strip
JA
Address setting jumper
∗ Refer to page 258 for details.
JB
Fan speed setting when compressor stops for thermostat OFF
∗ Refer to page 261 for details.
JC
Power failure recovery function (auto-restart)
∗ Refer to page 261 for details.
LED A
LED for service monitor (green)
FU1 (F1U),
Fuse (3.15 A, 250 V)
FU2
V1
Varistor
S1
JB
S21
S32
LED A
FU2
Indoor Unit
FG
H3
H2
H1
FU1
V1
2P206687-4