SA Indoor Unit
2. SA Indoor Unit
Category
Basic
Inverter (with inverter power control)
Functions
Operation limit for cooling
Operation limit for heating
PAM control
Compressor
Oval scroll compressor
Swing compressor
Rotary compressor
Reluctance DC motor
Comfortable
Power-airflow flap (horizontal blade)
Airflow
Power-airflow dual flaps
(horizontal blade)
Power-airflow diffuser
Wide-angle louvers (vertical blades)
Auto-swing (up and down)
Auto-swing (right and left)
3-D airflow
COMFORT AIRFLOW operation
Switchable fan speed (3 steps)
Comfort
Auto fan speed
Control
Indoor unit quiet operation
NIGHT QUIET mode (automatic)
OUTDOOR UNIT QUIET operation
(manual)
2 selectable temperature sensors
INTELLIGENT EYE operation
2-area INTELLIGENT EYE operation
Quick warming function
Hot-start function
Automatic defrosting
Operation
Automatic operation
Program dry function
Fan only
Lifestyle
POWERFUL operation (non-inverter)
Convenience
POWERFUL operation (inverter)
Priority-room setting
COOL/HEAT mode lock
HOME LEAVE operation
ECONO operation
Emergency operation switch
Signal receiving sign
R/C with back light
Temperature display
Note:
: Available
— : Not available
7
Functions
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Category
Health &
Air-purifying filter
Cleanliness
—
Titanium apatite deodorizing filter
—
Silver ion anti-bacterial drain pan
—
Longlife filter (option)
—
Air filter
—
Filter cleaning indicator
—
Wipe-clean flat panel
—
Washable grille
—
Good-sleep cooling operation
Timer
Setpoint auto reset
—
Setpoint range restriction
—
Schedule TIMER operation
—
24-hour ON/OFF TIMER
—
Count up/down ON/OFF TIMER
—
Off Timer (turns unit off after set time)
—
NIGHT SET mode
—
Worry Free
Auto-restart (after power failure)
(Reliability &
Self-diagnosis (R/C, LED)
Durability)
—
Wiring error check function
—
Anti-corrosion treatment of outdoor heat
exchanger
—
Flexibility
Multi-split/split type compatible indoor
—
unit
—
Flexible power supply correspondence
—
High ceiling application
—
Chargeless
—
Either side drain (right or left)
Drain pump
—
Power selection
°F/°C changeover R/C temperature
display (factory setting: °F)
Remote
Remote control adaptor
Control
(normal open pulse contact) (option)
—
—
Remote control adaptor
(normal open contact) (option)
—
—
DIII-NET compatible (adaptor) (option)
—
Wireless LAN connection (option)
—
1
—
—
1: Receiving sound only
SiUS121736EA
Functions
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
List of Functions
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—