Aiphone IS Series Setting Manual page 6

Local system
Hide thumbs Also See for IS Series:
Table of Contents

Advertisement

Title
Sub title
System setting Advanced station
settings
Zone setting
Chime setting
Registering sound
source
Registering sound
sequences
Registering daily
chime schedule
Chime schedule
setting
6
Item
Room sub
control unit/
Add-on
control unit
Zone number
-
Stations
-
PA outputs
-
(Sound file)
-
Sound number
-
Sound sequence
-
name
Step
-
Sound source
Sound file
Repeat times
Schedule number
-
Schedule name
-
Chime time
-
Sound source
-
Zone number
-
Chime priority
-
Weekly schedule
(Repeat setting)
Schedule start date
Schedule end date
(Chime schedule)
Individual schedule
(Date)
Daily chime schedule
Chime time
Sound source
Zone number
Chime priority
Schedule download -
Sub item
(Contact output
L1 to L4
terminal)
Contact type
Normally open (NO)/Normally closed (NC) Normally open
Trigger condition
None/Calling notice/Door release/PA
output
Calling notice
Normal: OFF/ON
(Only when "Calling
Priority: OFF/ON
notice" is selected at
Urgent: OFF/ON
"Trigger condition")
Door release
(Select from the sub stations registered
(Only when "Door
and set for each control unit.)
release" is selected at
"Trigger condition")
PA output
PA output 1 to 4
(Only when "PA output"
is selected at "Trigger
condition")
(Select from the registered ones.)
(Select from the list.)
(Select from the list.)
SF1 to SF15 (3MB in total, 2MB/file)
SS1 to SS20
Up to 24 alphanumeric characters
1 to 10
(Select from the registered ones.)
1 to 10
DS1 to DS10
Up to 24 alphanumeric characters
Hour: 0 to 23
Minute: 0 to 59
Second: 0 to 59
Sound file (Select from the registered
ones.)
/Sound sequence (Select from the
registered ones.)
/External sound source (1 or 2)
(Select from the registered ones.)
Normal/Priority/Urgent
Every week/Every other week
From the current day to 1 year ahead
From the start day to 1 year ahead
None/DS1 to DS10 (for each day of the
week)
From the current day to 1 year ahead
(Select from the registered ones.)
Hour: 0 to 23
Minute: 0 to 59
Second: 0 to 59
Sound file (Select from the registered
ones.)
/Sound sequence (Select from the
registered ones.)
/External sound source (1 or 2)
(Select from the registered ones.)
Normal/Priority/Urgent
(Download the chime (and transfer)
schedule data in CSV format.)
Setting range
L1
(NO)
None
Normal: OFF
Priority: OFF
Urgent: OFF
-
-
-
-
-
-
SS1
-
1
-
1
DS1
-
-
-
-
Normal
Every week
-
-
None
-
None
-
-
-
Normal
-
Default

Advertisement

Table of Contents
loading

Table of Contents