D. Vent Components Diagrams (continued)
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be used on a wall 4
in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the existing heat shields must be
field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B will be required.
15-1/8 in.
(384 mm)
(305 mm)
(184 mm)
1 in.
(25 mm)
14 in.
(356 mm)
3/8 in. (10 mm)
1 in. (25 mm)
SLP-TVHW
Vertical
Termination Cap
Figure 14.4 SLP Series Vent Components
71
8 in.
(203 mm)
12 in.
SLP-TRAP2
Horizontal Termination Cap
7-1/4 in.
7-3/4 to 10-3/8 in.
(197 to 264 mm)
12 IN.
305 mm
Heat & Glo • VRT-AUB • 2123-980_R14 • 12/14
Heat
Shield
Term Cap
Max
Effective
Length
DVP-FBHT
FireBrickTermination Cap
Minimum
Effective Length
Effective Length
5-1/4 in.
Trap2
133 mm
DVP-FBHT
SL-2DVP
SLP90
14 IN.
356 mm
Maximum
9-1/4 in.
235 mm
7-3/8 IN.
187 mm
17-7/8 IN.
454 mm