Note: if any of the original wire as supplied with the appliance must be replaced, it must be replaced
with type 105 ºC rated wire. Wires must have high temperature insulations.
Figure 12.2 Blower Diagram
C. Optional Accessories Requirements
• This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.
• Hearth & Home Technologies recommends that IntelliFire
Plus
wireless controls be used for their features and
TM
functionality with the IntelliFire Plus
WARNING! Risk of Shock! Label all wires prior to
disconnection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105 ºC rated wire. Wire must have high temperature
insulation.
56
OPTIONAL ACCESSORY
ignition system.
TM
Heat & Glo • VRT-AUB • 2123-980_R14 • 12/14
D. Blower
These fireplaces have a factory installed Fan, Electrical
Junction Box. These components are located behind the
lower door.
Use of the fan requires that the Junction Box (factory
installed) be connected to 220-240 VAC service before
permanently enclosing the fireplace. The access hole for
connecting the service wires is found on the right exterior
side of the unit.