Covers Removal For Servicing; Components Removal For Service; Parts Replacement; Adjustments And Replacement Parts - Heat & Glo VRT-BZ-N-AUB Owner's Manual

Hide thumbs Also See for VRT-BZ-N-AUB:
Table of Contents

Advertisement

K. Covers Removal For Servicing
Control Compartment Access Door
• Lift the lower door up and out to access the gas controls.
Trim Door and Glass Door
• Lift the front trim door up and out away from the appliance
side surrounds. Replace the door when servicing is
complete.
• Noting carefully how the brackets fit on the glass, release
the two spring latches at the top and two at the bottom
of the glass door. Carefully lift the glass up and out away
from the appliance.
Fixed Glass Assembly
WARNING! Risk of Asphyxiation! Handle fixed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
• DO NOT strike, slam or scratch glass.
• DO NOT operate fireplace with glass removed, cracked,
broken or scratched.
• Replace as a complete assembly.
Removing Fixed Glass Assembly
• Pull the four glass assembly latches out of the groove on
the glass frame. Remove glass door from the appliance
(see Figure 9.19).
Replacing Fixed Glass Assembly
• Replace the glass door on the appliance. Pull out and
latch the four glass assembly latches into the groove on
the glass frame.
LATCHES
(BOTH BOTTOM
AND TOP)
GLASS
ASSEMBLY
Figure 9.19 Fixed Glass Assembly
L. Components Removal For Service
• Release the screws at the base of the log grate and
carefully lift up and remove the logs and log grate.
• Remove the base pan.
• Unscrew the brackets at both ends of the burner and the
top two screws locating the pilot bracket. Slide the burner
away from the burner orifice.
45
Pilot Assembly/Ignition System
• Remove the log set, log grate and burner assembly.
• Disconnect the gas supply tube from the outlet side of
• Disconnect the orange ignitor wire (I) and white sensor
• Unscrew the pilot assembly bracket and remove, the pilot
M. Parts Replacement
Fan
• Unplug the fan from the AUX300CE and slide the fan out
• Fan can be operated at 3 speed levels using RC300AU
• The fan will automatically turn on after 3 minutes and will
Glass Panel
• To replace the glass door, place the bottom edge into the
N. Adjustments And Replacement Parts
Adjustments and replacement parts for this appliance should
only be done by a qualified service person. A wiring diagram
for the appliance is shown in Section 12. A service parts list
is shown in Section 16 of this manual.
O. Install Trim and/or Surround
• Install optional trim kits and/or surrounds using the
• Use non-combustible materials to cover the gap between
P. Air Shutter Setting
VRT-N-AUB
VRT-P-AUB
Heat & Glo • VRT-AUB • 2123-980_R14 • 12/14
valve.
wire (S) from module.
assembly along with silicone sealant grommet.
the front of the lower controls compartment.
remote and AUX300CE. Refer to RC300AU section.
stop 12 minutes after unit has been turned off.
lower holders, push glass against unit and secure the two
spring latches at the top and bottom.
instructions included with the accessory.
the sheet rock and the appliance (when applicable to the
model).
Natural Gas
1/2 in.
(12.7 mm)
N/A
Propane
Butane
N/A
N/A
7/16 in.
N/A
(11.11 mm)

Advertisement