Adjusting Thermostat
• Press the MENU button to activate the menu.
• Using the UP and DOWN arrows highlight the THERMO
icon and press SELECT.
• Use the UP and DOWN arrows to turn the THERMO ON
or OFF, then press SELECT (the SET TEMP will start
blinking). Using the UP and DOWN arrows select the
desired temperature and press SELECT.
NOTICE: If the THERMO function is on, the SET TEMP
can be adjusted at any time by pressing the UP and DOWN
arrows.
NOTICE: As the ROOM TEMP (RT) approaches SET TEMP
(ST), the remote system will automatically adjust the flame
height. If the RT rises above ST, the fireplace will shut down
the main burner. After this, the fireplace will turn back on
after the RT drops below the ST.
NOTICE: The system will remember the previous
TEMPERATURE setting when THERMOSTAT mode is
cycled ON or OFF.
NOTICE: If your installation includes an optional wired ON/
OFF wall switch, it should be in the OFF position when using
the RC300AU in thermostat mode.
Adjusting Timer
• Press the MENU button to activate the menu.
• Using the UP and DOWN arrows highlight the TIMER icon
and press SELECT.
• Use the UP and DOWN arrows to turn the TIMER ON
or OFF, then press SELECT. Using the UP and DOWN
arrows select the desired set time and press SELECT.
Timer operates in increments of 15, 30, 45, 60, 90, 120
and 180 minutes.
Setting the Child Lock
• Press and hold the MENU and UP arrow buttons
simultaneously for 4 seconds to enable or disable the
child lock feature.
NOTICE: No functions will be usable until child lock feature
is disabled.
63

Power Outage

• If fireplace battery backup system IS installed at time of
• If fireplace battery backup system IS NOT installed at
NOTICE: Battery polarity must be correct or module damage
will occur.
Manual Fireplace Shutoff
In the unlikely event that the remote wall switch malfunctions
and will not turn off the fireplace, call your dealer for service
assistance. In the meantime, you may choose one of the
following actions to turn off the fireplace:
CAUTION! Risk of burns! Fireplace surfaces are hot when
operating and during cool down. Use care and wear gloves
when opening the front and accessing components inside
the fireplace.
Check remote screen for battery level indicator, replace the
batteries if low battery is indicated (See Figure 12.13).
Turn off the control module:
• Open or remove the decorative front to access the control
• Move switch to OFF (See Figure 12.11).
Disconnect power to the control module:
• Open or remove the decorative front to access power cord
• Unplug the control module and/or remove back-up
Shut off gas to the appliance:
• Open or remove the decorative front and locate the gas
• Rotate the shut off valve 90 degrees to turn off gas supply.
Turn off power to the fireplace (if back-up batteries are
not installed):
• Locate house circuit breaker for fireplace.
• Turn off the circuit breaker.
Heat & Glo • VRT-AUB • 2123-980_R14 • 12/14
power outage, fireplace operation will not be interrupted.
time of power outage, fireplace will shut off. To resume
fireplace operation, install battery backup.
module.
to the junction box and/or back-up batteries.
batteries.
shut-off valve to the left of the gas control.