12

Electrical Information

A. Wiring Requirements
NOTICE: This appliance must be installed by a qualified
electrician in accordance with the relevant national and local
regulations.
• Wire the appliance junction box to 220-240 VAC. This is
required for proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
220-240 VAC to the valve or to the appliance wall switch.
Incorrect wiring will damage controls.
NOTICE: The mains supply to the appliance must have
isolation of a minimum 3 mm contact separation in both poles.
WARNING! Risk of Injury! The gas supply shall be
shut off prior to disconnecting the electrical power and
removing batteries (if installed) before proceeding with any
maintenance to the appliance.
GROUND
TO CHASSIS
TO AUX300CE
TO CORD ASSEMBLY
120VAC
JUNCTION CORD
Figure 12.1 IPI Wiring Diagram /RC300AU
55
MODULE RESET
SWITCH
OPTIONAL
WIRE ASSEMBLY
CONTROL MODULE
WALL SWITCH
JUMPER WIRE
ORANGE
GREEN
(PILOT)
(MAIN)
Heat & Glo • VRT-AUB • 2123-980_R14 • 12/14
B. IntelliFire Plus
• Wire the appliance junction box to 220-240 VAC for proper
operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 12.1, IPI Wiring Diagram.
• This appliance is equipped with an IntelliFire Plus
valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the appliance OR install 4 AA cell
batteries (not included) into the battery pack before use.
• An in-line isolation switch must be installed within 1
meter of the fireplace. This is required for servicing and/
or resetting the control module in the event of a control
module LOCK-OUT.
GAS TUBE
IGNITOR
FLAME
SENSE
I
S
8K1 WIRE
HARNESS
RED
BLACK
BROWN
GROUND
Ignition System Wiring
TM
240V FAN (OPTIONAL)
OPTIONAL
AUX300CE MODULE (OPTIONAL)
FAN
AUX 1
AUX 2
TO OPTIONAL
COMPONENTS
OPTIONAL ON/OFF
WALL SWITCH
BATTERY PACK
6V DC (C X 4)
control
TM
TO JUNCTION
CORD 220-240 VAC