Heat & Glo TIARA I Installer's Manual

Heat & Glo TIARA I Installer's Manual

Direct vent gas fireplace heater
Hide thumbs Also See for TIARA I:
Table of Contents

Advertisement

WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury or death.
- Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your
building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas sup-
plier, call the fire department.
- Installation and service must be
performed by a qualified installer,
service agency, or the gas supplier.
1. This appliance may be installed in an after-
market, permanently located, manufactured
(mobile) home, where not prohibited by
local codes.
2. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
Installers Guide
Guide d'installation
Model/Modèles:
Tiara I and Tiara II
1
AVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans
cette notice pour réduire au minimum
le risque d'incendie ou d'explosion ou
pour éviter tout dommage matériel, toute
blessure ou la mort.
– Ne pas entreposer ni utiliser d'essence
ni d'autres vapeurs ou liquides inflam-
mables dans le voisinage de cet appareil
ou de tout autre appareil.
– QUE FAIRE SI VOUS SENTEZ UNE
ODEUR DE GAZ
• Ne tentez pas d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne
pas vous servir des téléphones se
trouvant dans le bâtiment où vous
vous trouvez.
• Évacuez la pièce, le bâtiment ou la
zone.
• Appelez immédiatement votre fournis-
seur de gaz depuis un voisin. Suivez
les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournis-
seur de gaz, appelez le service des
incendies.
– L'installation et l'entretien doivent
être assurés par un installateur ou un
service d'entretien qualifié ou par le
fournisseur de gaz.
1. Cet appareil peut être utilisé dans un mobile
home, installé à demeure si les règlements
locaux le permettent.
2. Cet appareil ne peut être utilisé qu'avec
le type de gaz spécifié sur la plaque de
caractéristiques. Il n'est pas convertible et
ne peut pas fonctionner avec d'autres gaz
que celui indiqué, à moins qu'un ensemble
homologué ne soit utilisé.
281-900EFC 03/04

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo TIARA I

  • Page 1 Installers Guide Guide d’installation Model/Modèles: Tiara I and Tiara II AVERTISSEMENT: Assurez-vous de bien WARNING: If the information in these suivre les instructions données dans instructions is not followed exactly, a fire cette notice pour réduire au minimum or explosion may result causing property le risque d’incendie ou d’explosion ou...
  • Page 2: Table Of Contents

    Heat n Glo à ventilation directe ........7 Pre-installation Preparation ...........7 Avant l’installation ............7 Diagram of the Tiara 1 & II........8 & 9 Schéma du modèle Tiara I & II 8 & 9 Section 3: Installing the Stove........10 Section 3: Installation ..........10 Step 1 Locating the Stove and Dimensions ....10...
  • Page 3: Safety And Warning Information

    AVERTISSEMENT: Une installation, un WARNING: Improper installation, réglage, une modification, un entretien adjustment, alteration, service or ou une maintenance incorrects peuvent maintenance can cause injury or prop- entraîner des blessures ou dommages erty damage. Refer to this manual. matériels. Consulter le manuel. Pour toute assistance ou pour obtenir For assistance or additional informa- de plus amples informations, consulter...
  • Page 4 NEVER OBSTRUCT the flow of combustion and NE PAS OBSTRUER le débit de l’air de combustion ou ventilation air. Keep the front of the appliance CLEAR d’échappement. Veiller à ce que le devant de l’appareil of all obstacles and materials for servicing and proper soit toujours DÉGAGÉ...
  • Page 5: Service Parts List

    TIARA I & II (NG, LP) Service Parts List / (GN, PL) Liste des pièces de rechange with Exploded Parts Diagram / (GN, PL) Vue éclatée des pièces IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts.
  • Page 6: Section 1: Approvals And Codes

    Installers Guide have been tested to certification approuvés par les laboratoires concernés. standards and listed by the applicable laboratories. CERTIFICATION STANDARD CERTIFICATION STANDARD MODEL Tiara I and II MODÈLE Tiara I et II LABORATORY Underwriters Laboratories LABORATOIRE Underwriters Laboratories TYPE...
  • Page 7: Section 2: Getting Started

    Mise en marche Getting Started Présentation des appareils de chauffage Introducing the Heat N Glo Heat N Glo à ventilation directe Direct Vent Gas Stoves Heat-N-GLo direct vent gas stoves are designed to Les appareils de chauffage Heat-N-Glo à ventilation operate with all combustion air siphoned from outside directe sont prévus pour aspirer l’air de l’extérieur et refouler les gaz d’échappement à...
  • Page 8: Diagram Of The Tiara 1 & Ii

    Figure 1. Schéma du modèle Tiara I Figure 1. Diagram of the Tiara I (889mm) 10 1/2 (267mm)
  • Page 9 Mise en marche Getting Started (suite) (continued) Figure 2. Schéma du modèle Tiara II Figure 2. Diagram of the Tiara II 14 3/4 (375mm) Ø6 5/8 (168mm) 7 1/2 (191mm) 15 1/4 (387mm) 19 3/8 (330mm) (491mm) 29 1/2 (749mm) 43 1/2 (1105mm) 29 1/4...
  • Page 10: Section 3: Installing The Stove

    The diagram below shows space and clearance les espaces d’isolation à prévoir pour l’installation de requirements for locating the stove within a room. l’appareil de chauffage dans une pièce. 16 1/8 (410mm) Tiara I 9 7/8 (251mm) 4 (101mm) 33 3/8 (848mm) 6 (152mm)
  • Page 11 Plancher Rear (Tiara I) Arrière (Tiara I) (Tiara II) (Tiara II) Sides (Tiara I) Côtés de l’appareil (Tiara I) (Tiara II) (Tiara II) Floor to Ceiling 1830 Plancher au plafond Minimum Clearances from the Distances minimum entre le conduit Vent Pipe to Combustible Materials de ventilation et les matériaux combustibles...
  • Page 12: Step 2 Installing The Vent System

    Guide d’installation. collars for all vent systems unless using the AVERTISSEMENT : Avec tous les systèmes Optional Kit #970D on model Tiara I. d’évacuation, un conduit droit d’au moins 61 cm Identifying Vent Components de long DOIT être rattaché aux collets de raccord The vent systems installed on this gas stove may de l’appareil, sauf si le module facultatif n°970D...
  • Page 13 Installing the Stove Installation (continued) (suite) 6 1/2 in. 6 3/8 in. (165mm) (162mm) 9 1/4 in. (235mm) 6 1/2 in. (165mm) 9 5/8 in. 6 3/8 in. (244mm) 6 5/8 in. (162mm) (168mm) SL-45D 6 5/8 in. (168mm) 9 5/8 in. (244mm) SL-90D 17-2 4 in.
  • Page 14 (continued) (suite) Système de ventilation vertical droit Straight Vertical Vent System Tiara I Tiara I Lorsqu’une section verticale égale ou supérieure à When a vertical run of 12 feet and higher is attached 3,65 m (12 ft) est attachée directement en haut de directly to the top of the stoves, further baffling l’appareil de chauffage, un déflecteur supplémentaire...
  • Page 15 La flamme aura ainsi le temps d’atteindre sa taille et sa couleur habituelles avant que vous régliez l’obturateur and darker. d’air. Au fur et à mesure que l’obturateur se ferme, la flamme devient plus haute et plus foncée. Tiara I FIREBOX (FOYER SUPERIEURE) ROUND BAFFLE (D FLECTEUR È...
  • Page 16 Installing the Stove Installation (continued) (suite) VERTICAL VENT (VENTILATION VERTICALE) 2’ (610mm) MIN. 40’ (1200cm) MAX. Figure 7. Straight Vertical Vent Figure 7. Système de ventilation System vertical droit...
  • Page 17: Installing The Stove

    Tiara I. REMARQUE: Le kit n 970D en option peut être utilisé pour ce type d’installation du modèle Tiara I. Figure 8. Vent System with One Figure 8. Système de ventilation 90° Elbow avec un coude à 90°...
  • Page 18 Installing the Stove Installation (continued) (suite) Tiara I Tiara II VENTING WITH TWO (2) 90 ELBOWS VENTING WITH TWO (2) 90 ELBOWS (VENTILATION AVEC DEUX (2) COUDES À 90 (VENTILATION AVEC DEUX (2) COUDES À 90° 2’ MIN.(610mm) 2’ MAX.(610mm) 2’...
  • Page 19 Installing the Stove Installation (continued) (suite) Tiara I VENTING WITH THREE (3) 90 ELBOWS (VENTILATION AVEC TROIS (3) COUDES À 90°) 2’ MIN.(610mm) 2’ MAX.(610mm) 3’ MIN.(914mm) 3’ MAX.(914mm) 4’ MIN.(120cm) 4’ MAX.(120cm) 18’ MIN.(540cm) 18’ MAX.(540cm) +H+H = 40’ MAX.(1200cm) = 18’...
  • Page 20: Installing Vent Components

    Installing the Stove Installation (continued) (suite) B. Installing Vent Components B. Pose des éléments de ventilation Avant de commencer l’installation, lire les instructions Before starting installation of vent kits, the installer should read Installing the Vent System on pages 12 du Guide d’installation de l’appareil de chauffage thru 22, to ensure that the proper system has been et les instructions des kits de ventilation pages 12...
  • Page 21 Installing the Stove Installation (continued) (suite) 1. Apply the stove cement. ST ARTING COLLA R (COLLIE R D E DÉP ART ) 1. Mettre du ciment réfrac- 2.Line up the internal beads taire. and rotate the pipe sections clockwise until locked. 2.
  • Page 22 Installing the Stove Installation (continued) (suite) Continuer à ajouter des Continue adding vent sections et à les verrouiller components, locking each successivement succeeding component into place. Figure 12. Figure 12. Adding Ajout de sections Venting Components 3. Pose des supports de montage 3.
  • Page 23 Installing the Stove Installation (continued) (suite) 4. Install Firestops 4. Pose des coupe-feu Sections horizontales - Les coupe-feu sont For Horizontal Runs - Firestops are REQUIRED OBLIGATOIRES de chaque côté d’un mur on both sides of a combustible wall through which combustible traversé...
  • Page 24 Installing the Stove Installation (continued) (suite) Sections verticales - Un coupe-feu de plafond est For Vertical Runs - One ceiling firestop is REQUIRED OBLIGATOIRE au trou de chaque plafond traversé at the hole in each ceiling through which the vent par le conduit.
  • Page 25: Vent Termination

    Installing the Stove Installation (continued) (suite) If the area above the ceiling is NOT an attic, position Si l’espace au-dessus du plafond N’EST PAS un and secure the ceiling firestop on the ceiling side of grenier, poser et fixer le coupe-feu du côté plafond the previously cut and framed hole.
  • Page 26 Installing the Stove Installation (continued) (suite) AVERTISSEMENT: POSER LA MITRE DE WARNING: THE TERMINATION CAP MUST FAÇON À CE QUE LA FLÈCHE SOIT BE POSITIONED SO THAT THE ARROW DIRIGÉE VERS LE HAUT. IS POINTING UP. Kit de mitre ronde: For roundcap termination kits: •...
  • Page 27 Installing the Stove Installation (continued) (suite) = AREA WHERE TERMINAL IS NOT PERMITTE = VENT TERMINAL = AIR SUPPLY INLET OPENABLE FIXED CLOSED (OUVRABLE) (CONDAMNÉE) = MITRE = PRISE D’AIR J o r K = ZONE OÙ LA MITRE (J ou K) EST INTERDITE A = 12"...
  • Page 28 Installing the Stove Installation (continued) (suite) Mitres verticales - Pour situer le conduit et poser For Vertical Terminations - To locate the vent and les sections de conduit: install the vent sections: • Déterminer le centre du conduit, tracer un repère •...
  • Page 29: Step 3 The Gas Control System

    Installing the Stove Installation (continued) (suite) To seal the roof hole, and to divert rain and snow Pour assurer l’étanchéité du toit et protéger le conduit from the vent system: de la pluie et de la neige: • Attach a flashing to the roof using nails, and use •...
  • Page 30: Step 4 The Gas Supply Line

    Installing the Stove Installation (continued) (suite) 3/8” (10mm) STANDING PILOT (VEILLEUSE) Figure 22. Figure 22. Commandes Gas Controls Systems d’alimentation en gaz Étape 4 Step 4 Raccordement au gaz The Gas Supply Line REMARQUE : Le conduit gaz doit être installé conformément aux codes de construction locaux.
  • Page 31: Step 5 Gas Pressure Requirements

    Installing the Stove Installation (continued) (suite) USE A WRENCH ON SHUT -OFF VA LV E MANUAL WHEN TIGHTENING SHUT -OFF VA LV E GAS LINE (ROBINET MANUEL) (UTILISER UNE CL É SUR LE ROBINET POUR SERRER CONDUITE DE GAZ) GA S V AL VE (VANNE DE COMMANDE) FLEX CONNECT OR...
  • Page 32: Step 6 Wiring The Stove

    Installing the Stove Installation (suite) (continued) Étape 6 Step 6 Câblage Wiring the Stove REMARQUE: Faire effectuer le câblage par un NOTE: Electrical wiring must be installed by a électricien qualifié. competent electrician. For Standing Pilot Ignition Wiring Câblage de l’allumage par veilleuse Spécifications Appliance Requirements •...
  • Page 33 Installing the Stove Installation (suite) (continued) 6. Replace rear shield. 6. Remettez l’écran arrière en place. 7. Branchez le cordon électrique du ventilateur 7. Plug the fan electrical cord into the junction box à la prise de la boîte de dérivation étiquetée receptacle marked “FAN”.
  • Page 34 Installing the Stove Installation (continued) (suite) AVERTISSEMENT: NE PAS RACCORDER WARNING: DO NOT CONNECT 110-120 VAC L’INTERRUPTEUR MURAL TO THE WALL SWITCH OR THE CONTROL COMMANDE SUR 110-120 V CA POUR VALVE WILL BE DESTROYED. ÉVITER LA DESTRUCTION DE LA VANNE DE COMMANDE.
  • Page 35: Step 7 Finishing

    Installing the Stove Installation (continued) (suite) Step 7 Étape 7 Finishing Finitions AVERTISSEMENT: LORS DES FINITIONS WARNING:WHEN FINISHING THE STOVE, DE L’APPAREIL DE CHAUFFAGE, NE NEVER OBSTRUCT OR MODIFY THE JAMAIS OBSTRUER OU MODIFIER AIR INLET/OUTLET GRILLES IN ANY GRILLES D’ADMISSION MANNER.
  • Page 36: Step 8 Installing Logs And Ember Material

    Ember Material Caractéristiques de la vitre: Glass Specifications: Tiara I 13 3/8 in. x 14 in. en céramique Tiara I 13 3/8” x 14” Ceramic Tiara II 14 3/4 in. x 21 1/2 in. en céramique Tiara II 14 3/4” x 21 1/2” Ceramic...
  • Page 37: Log Placement

    Tiara I Model: LOG PLACEMENT INSTRUCTIONS (Log Set Assembly 844-9320) CAUTION: Logs are fragile! Carefully remove the logs from the packaging. LOG #1: Place Log #1 behind the back of the burner with notch over the pilot. Slide log to the left and make sure that the log is touching the back of the burner.
  • Page 38: Log Placement Instructions

    Model: Tiara II LOG PLACEMENT INSTRUCTIONS (Log Set Assembly 844-9330) CAUTION: Logs are fragile! Carefully remove the logs from the packaging. LOG #1 : Place log #1 in back of the stove so the notch fits over the pilot and the back of the log hits the back of the stove.
  • Page 39 MODEL: TIARA II (CONT’D) LOG PLACEMENT INSTRUCTIONS (LOG SET ASSEMBLY 844-9330) LOG # 3: Place #3 against the tab on the right wall and the tab on the burner pan. Make sure no burner ports are covered in the front.
  • Page 40: Step 9 Before Lighting The Stove

    Installing the Stove Installation (continued) (suite) Étape 9 Step 9 Avant l’allumage Before Lighting the Stove Avant d’allumer l’appareil de chauffage, ne pas oublier de: Before lighting the stove, do the following: Retirez tous les papiers et tous les documents qui Remove all paperwork and documents from underneath the fireplace.
  • Page 41: Section 4: Maintaining And Servicing Your Stove

    Maintaining and Servicing Your Stove Entretien et révision Entretien Stove Maintenance Bien que la fréquence d’entretien et de révision Although the frequency of your stove servicing and de l’appareil de chauffage dépende du volume maintenance will depend on use and the type of d’utilisation et du type d’installation, nous installation, you should have a qualified service recommandons un examen de l’appareil par un...
  • Page 42 S’assurer que les flammes sont STANDING PILOT are steady—not lifting or stables, qu’elles ne montent pas (VEILLEUSE) floating. et ne flottent pas. 3/8” (10mm) Tiara I Tiara II EMBERS (BRAISES) Figure 28. Figure 29. Figure 29. Figure 28. Configuration des...
  • Page 43 Wing Bolt Boulon d’aile After logs have been Après bûches installed pull skirt plate naturels aient été plat installé forward (see Figure 30). de jupe de traction en avant Insert wing bolt (see Figure (voir le schéma 30). Insérez 31) from underneath and le boulon d’aile (voir le behind the ashlip (see schéma 31) de sous et der-...
  • Page 44 Tiara I & II ATTENTION INSTALLER: PLEASE RETURN THESE INSTRUCTIONS TO THE STOVE OW NER W HEN INSTALLATION IS COMPLETED.

This manual is also suitable for:

Tiara ii

Table of Contents