E. Flue Pipe Assembly
Note: Align seams to engage pipe,
then rotate counterclockwise to lock
Figure 7.12
Step 1.
Balanced flue pipe is designed with a locking connection.
To connect the flue system to the gas stove flue outlet:
• Lock the flue components into place by sliding the pipe
section onto the collar.
• Align the seam of the pipe and seam of collar to allow
engagement. Rotate the flue component to lock into place.
Use this procedure for all flue components. See Figure
7.12.
• Continue adding flue components, locking each
succeeding component into place.
• Ensure that each succeeding flue component is securely
fitted and locked into the preceding component.
!
Fire Risk.
Explosion Risk.
Combustion Fume Risk.
Use flue run supports per installation instructions.
Connect flue sections per installation instructions.
• Maintain all clearances to combustibles.
• Do NOT allow flue to sag below connection
point to gas stove.
• Maintain specified slope (if required).
Improper support may allow flue to sag or separate.
31
WARNING
Heat & Glo • VRT-AUB • 2123-980_R14 • 12/14
F. Horizontal Penetration Framing
90 DEGREE
ELBOW
PIPE LENGTH
PIPE LENGTH
Figure 7.13
Step 2.
For installations using a round support box/wall thimble
(check pipe manufacturer's instructions), mark the wall for
a 9 in. x 9 in. (229 mm x 229 mm) square hole. The center
of the square hole should line up with the center line of
the horizontal pipe. Cut and frame the hole in the exterior
wall where the flue will be terminated. If the wall being
penetrated is constructed of noncombustible material, i.e.
masonry block or concrete, a 7 in. (178 mm) diameter hole
is acceptable.
Step 3.
Position the horizontal termination cap in the center of the 9
in. x 9 in. (229 mm x 229 mm) square hole and run a bead
of non-hardening mastic around its outside edges, to make
a seal between it and the wall. Attach termination cap to the
exterior wall with the four wood screws provided. The arrow
on the flue cap should be pointing up.
TERMINATION CAP
WALL THIMBLE
WALL THIMBLE
COVER