Door Handle - Vulcan-Hart C24EO3 Service Manual

C24eo series electric countertop steamers
Hide thumbs Also See for C24EO3:
Table of Contents

Advertisement

C24EO SERIES ELECTRIC COUNTERTOP STEAMERS - REMOVAL AND REPLACEMENT OF PARTS
Fig. 22
3.
Remove gasket plate.
4.
Remove gasket from inner door panel.
5.
Remove RTV from bottom part of inner door
panel. Apply new RTV 109 to bottom of door
where shown when assembling gasket to door.
Fig. 23
6.
Place a small amount of RTV109 into the inner
door panel gasket screw holes before assembly.
7.
Position the new gasket on gasket plate and
reverse procedure to install.

DOOR HANDLE

electrical power to the machine and
follow lockout / tagout procedures.
REMOVAL
1.
Open door.
2.
Remove screws from top and bottom of door
assembly.
Disconnect the
Page 11 of 27
Fig. 24
3.
Pull outer door housing away from inner door
panel starting at the hinge side of door to
separate the door halves.
NOTE: The smaller radius of the step spacers fit into
the slots of the outer door housing and is used to
provide clearance for handle operation.
4.
Remove lock nuts and stepped spacers from
threaded studs of door handle.
Fig. 25
INSTALLATION
1.
Apply Lubriplate 630AA around slots of outer
door housing where step spacers contact
housing.
2.
Install door handle into outer door housing such
that hinge side of door housing is to the left and
arrow on handle is pointed upward.
3.
Install step spacer with smaller radius toward
handle and door housing. Smaller radius is a slip
fit with outer door housing slot.
F25386 (0415)