Step 2, Mount Template; Step 3, Size And Install Ductwork - Monogram ZV421 Installation Instructions Manual

Island vent hoods
Table of Contents

Advertisement

Installation
instructions
ISTEP 2J MOUNT TEMPLATE
. Select the template
for gour hood size.
_;_ !ff-_"_
F"
"andAligntapethe
intemplateplace,
with the marks on the ceiling _
UI_
l
- Be sure the template
is oriented correctlg,
[][][]
with the front of the hood.
. Use a plumb to check to be sure the mount-
".
ing holes will provide parallel alignment with
the countertop
below,
cr
....
. Center punch all hole locations.
. Drill pilot holes in the 4 screw locations. Use a
3/16" bit and drill approximatelg
1-1/2" deep.
. Drive 4 Hex head wood screws (Screws A)into
the center of the ceiling joists and cross fram-
ing. Leave a 1/4" gap to allow the screw head
to engage the keghole slots on the support
frames.
, Cut the 10-1/2" duct opening through the
sheet rock.
STEP 31 SIZE AND INSTALL DUCTWORK
. Measure from house duct flange to bottom of
support frame. Subtract 4-3/8" for clearance to the
bottom of the support frame.
. Cut the 10" duct length to size.
. Secure duct to house ducting with sheet metal
screws.
. Seal all connections
with duct tape.
. Attach the duct collar Iooselg, about 1" from the
bottom of the duct using Screws B.
..................
i...........
i_-!l I" Duct
Duct : :):1 14
c°llar"i"-i-._:!::_
'
•-; ..........
: 4-3/8" Clearance
II /'
_o___
o, to Bottom of Fran
_4
49
80209
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zv541

Table of Contents