Toshiba E-Studio 2500C Manual page 338

Hide thumbs Also See for E-Studio 2500C:
Table of Contents

Advertisement

8 Troubleshooting
Domain - User account is locked and cannot be
used for logon
Domain - Invalid logon hours for the User
Active Directory Domain - Clock Skew error due to
difference in Time between Server and MFP
Active Directory Domain - Kerberos Ticket has
expired and cannot be used for Authentication
Active Directory Domain - Verification of the Ticket
has failed
Active Directory Domain-The Domain specified
could not be found
Information Failed User Authentication
SNTP Server - Connect Error has occurred
Link Local address of IPv6 was duplicated.
Stateful address of IPv6 was duplicated.
Stateless address of IPv6 was duplicated.
Manual address of IPv6 was duplicated.
Secure Update to Primary DDNS failed
Secure Update to Secondary DDNS failed
IPv6 Update to Primary DDNS failed
IPv6 Update to Secondary DDNS failed
IPv4 Update to Primary DDNS failed
IPv4 Update to Secondary DDNS failed
336
TopAccess Error Messages
TopAccess Message
Corrective Action
The lockout duration could be specified in account
lockout security policy. If so please retry after the
lockout duration.
The Administrator has set restrictions on the logon
hours. The logon hours can be modified from
Active Directory Users and Computers.
The clocks need to be synchronized. Please con-
firm if SNTP is configured correctly on the equip-
ment.
Please confirm the validity period of the ticket set
by the Kerberos server. Please retry again after the
fresh ticket is issued.
Please verify the username and password and
retry again. If the problem persists please contact
the Administrator.
Please enter the correct domain name in network
settings. If the problem persists please contact the
Administrator for the correct realm name for your
server.
Check DomainName/UserName/Password
The equipment could not connect to the SNTP
Server. Please confirm the SNTP settings.
The link-local address of IPv6 is overlapping with
that of other device. Confirm the link-local address
of IPv6 and then set a new address.
The stateful address of IPv6 is overlapping with
that of other device. Confirm the stateful address
of IPv6 and then set a new address.
The stateless address of IPv6 is overlapping with
that of other device. Confirm the stateless address
of IPv6 and then set a new address.
The manual address of IPv6 is overlapping with
that of other device. Confirm the manual address
of IPv6 and then set a new address.
The equipment could not update Secure Primary
DDNS during DNS server update using IPv4.
The equipment could not update Secure Second-
ary DDNS during DNS server update using IPv4.
The equipment could not update Primary DDNS
during DNS server update using IPv6.
The equipment could not update Secondary DDNS
during DNS server update using IPv6.
The equipment could not update Primary DDNS
during DNS server update using IPv4.
The equipment could not update Secondary DDNS
during DNS server update using IPv4.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio 3500cE-studio 3510c

Table of Contents