(3) Paper transfer unit

To avoid print quality problems due to paper dust and debris, clean the paper transfer unit in the
following manner:
Pull the paper transfer unit release lever 1 up and draw the paper transfer unit all the way out until
it stops. Wipe the paper dust on the upper registration roller 2 and the paper ramp 3 using the
wiper cloth 4 included in the toner kit.
Do not touch the transfer roller 5 (black sponge roller) when wiping the paper
CAUTION
ramp 3.
Area 6 below is factory-applied with lubricating oil. When cleaning the paper
transfer unit 7, do not use alcohol to clean this area. If the oil is completely
removed, an incorrect action of the MP tray paper sensor (8, actuator) will result.
5
2
Figure 3-1-9 Cleaning the upper registration roller and the paper ramp
FS-1900
3
4
1
3-12
8
6
7