No Reaction At Power Up - Intermec EasyCoder PD41 Service Manual

Hide thumbs Also See for EasyCoder PD41:
Table of Contents

Advertisement

Chapter 1 — Troubleshooting the PD41/PD42

No Reaction at Power Up

Printer Problems at Power Up
Problem
Error during printing
No printing due to software error
6
The electronics compartment contains wires and components with
dangerous voltage (up to 380V). Always switch off the power and
unplug the power cord before you remove the cover over the electronics
compartment!
Im Elektronikfach gibt es Kabel und Komponenten, die hohe
Spannungen (bis zu 380 V) führen. Immer die Stromversorgung
abschalten und das Netzkabel abziehen, bevor die Abdeckung des
Elektronikfachs abgenommen wird!
Solution
• Check if the printer is out of media or
transfer ribbon
• Check that the printhead lever is closed
and locked
• If the printhead is closed and locked, but
the problem persists, the headlift sensor
may be out of order. Check connection to
P34 on the main board. Check headlift
microswitch.
• Check if media is jammed/tangled up.
Clear the jam and reload. Clean parts that
may have been exposed to the media's
adhesive using isopropyl alcohol or a
cleaning card.
• Check the light path between the upper
and lower parts of the label gap sensor to
see if it is obstructed by dust, adhesive, or
stuck labels. Clean using isopropyl alcohol
or a cleaning card.
• Recalibrate the sensors by running a
testfeed.
• Check to see if a bad command was sent
to the printer via Fingerprint or direct
protocol
• Check the Fingerprint application or the
last issued instruction in Direct Protocol
Refer to
"Headlift Sensor" on page 48
Fingerprint Command Reference
Manual (P/N 937-005-xxx
EasyCoder PD41/PD42 Printer Service Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Easycoder pd42

Table of Contents