Switch Installation
To prevent airflow restriction, allow clearance around the ventilation openings to be at least: 3 in. (7.6 cm) Statement
1076
Figure 12: Mounting the Switch Under a Desk or Shelf

Wall-Mounting

Read the wall-mounting instructions carefully before beginning installation. Failure to use the correct hardware
or to follow the correct procedures could result in a hazardous situation to people and damage to the system.
Statement 378
Do not wall-mount the switch with its front panel facing up. Following safety regulations, wall-mount the
Caution
switch with its front panel facing down or to the side to prevent airflow restriction and to provide easier
access to the cables
Step 1
Locate the screw template. The template is used to align the mounting screw holes.
Step 2
Position the screw template so that the edge that is marked as CABLE SIDE ENTRY faces toward the floor.
For the best support of the switch and cables, make sure that you attach the switch securely to a wall stud or to
Note
a firmly attached plywood mounting backboard
On a Desk, Shelf, or Wall (with Mounting Screws)
Catalyst 3560-CX and 2960-CX Switch Hardware Installation Guide
21